American DJ
®
- www.americandj.com - Vizi Beam 5R™ Instruction Manual Page 39
American DJ
®
- www.americandj.com - Vizi Beam 5R™ Instruction Manual Page 40
Vizi Beam 5R™
Editing Program
13. Repeat steps 3-12 to edit other scenes, you can edit and
save 48 scenes maximum.
14. Press MODE/ESC to exit, now you have edited and saved
scenes using the control board. The number of steps can be
defined under “Step” and the scenes can be called up under
“Run”. To run the scenes see page 35.
Editing procedure 2: Using an external controller.
1. Access the main menu.
2. Tap the UP button until “
EDIT
” is displayed. Press ENTER.
3. The display will show “
SC01
”, this stands for the scene
number to be edited. For example: If “
SC01
” is displayed, you
will be editing scene 1.
4. Change the scene number by pressing the UP button.
5. Press ENTER, the display will show “
C-01
”, the “1” stands for
the channel number 1.
6. Press the UP button until “
CEDT
” is displayed, press ENTER.
7. The display will show “
OFF
”, press the UP button so that “
ON
”
is displayed, press ENTER.
8. The display shows “
SC02
”. You have successfully down-
loaded the first scene.
9. Adjust the Step-time. needed by pressing the UP button.
10. Call up the second scene in your controller now.
11. Repeat steps 3-6 until all desired scenes are downloaded.
12. Press MODE/ESC to exit. The number of steps can be
defined under “Step” and the scenes can be called up under
“Run”.
Vizi Beam 5R™
Error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will flash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “03Er,” it means there is some type of
error with the channel 3 motor. If there are multiple errors during
the start-up process they will all flash in the display. For exam-
ple: if the fixtures has errors on channel 1 and channel 3 all at
the same time, you will see the error message flash “01Er”, and
“03Er repeated 5 times.
If an error does occur during the initial start-up procedure the
fixture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
fixture will make the following determinations:
1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the fixture has less than 3 errors, there-
fore most other functions will work properly. The fixture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
This message will appear after a fixture reset, if the pan-yoke’s
magnetic-indexing circuit malfunctions (sensor failed or magnet
is missing) or there is a stepper motor failure (defective motor
or a defective motor IC drive on the main PCB).
03Er – TILT movement error:
This message will appear after a fixture reset, if the tilt mag-
netic-indexing circuit malfunctions (sensor failed or magnet is