background image

SYSTEM MENU

The fixture includes an easy to navigate system menu control panel display where all necessary settings 

and adjustments are made. Turn the unit on, press the MENU button to access the menu mode, and 

press the UP/DOWN button until the required function is displayed on the monitor. Select the function 

by pressing the ENTER button. Use the UP/DOWN button to navigate the submenu, then press the 

ENTER button to store selection, and automatically return to the last menu. To exit the menu mode, 

press the MENU button, or let the unit idle 30 seconds. The screen will automatically lock, and can be 

unlocked by pressing the MENU button for at least 10-seconds.

24

Содержание HYDRO BEAM X12

Страница 1: ...HYDRO BEAM X12 User Instructions...

Страница 2: ...information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ADJ PRODUCTS LLC World Head...

Страница 3: ...e Lamp Warning 12 Lamp Installation 13 Torque Settings for Screws 14 Torque Screw Locations 15 Color Wheel 16 Gobo Wheel 17 Fixture Installation 18 Connections 21 DMX Set Up 22 DMX Addressing 23 Syste...

Страница 4: ...ort team for further instructions Please do not return this kit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the tra...

Страница 5: ...repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof includ...

Страница 6: ...second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ing...

Страница 7: ...the lamp if it has become damaged or thermally deformed The luminaire is intended for professional use only The light source contained in this luminaire shall only be replaced by the manufacturer qual...

Страница 8: ...ILE IN USE UNPLUG POWER BEFORE SERVICING FIXTURE NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT Maximum ambient temperature is Ta 40 C DO NOT operate it where the temperature is higher than thi...

Страница 9: ...imped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connector into the fixture If the power cord or any...

Страница 10: ...ris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is...

Страница 11: ...OVERVIEW UP Button ENTER Button LCD Menu Control Display IP65 Locking 5 Pin DMX In Out Gore Valve LENS SERVICE PORT IP65 Locking Power Connector In Out DOWN Button MENU Button Fuse T 10A 11...

Страница 12: ...s the ENTER button When the unit reaches10 of lamp life left the display will again flash the message Replace The Lamp Soon This message will flash for up to 10 minutes To confirm this warning and ret...

Страница 13: ...screws on the head of the fixture and open the fixture head covers Unplug the fan and loosen the screw that secures the safety cable 3 Loosen the screw that holds the lamp in place Unplug the leads an...

Страница 14: ...6 7 9 6 In Lb 4mm Hex 3 Yoke Arm Cover to Yoke Frame 11 x Each Side 22 Total 6 5 8 7 In Lb 3mm Hex 4 Access Cover to Yoke Frame x4 Manual Screwdriver 3mm Hex 5 Bottom Cover to Base Casting x12 6 7 9 6...

Страница 15: ...TORQUE SCREWS LOC ATI O NS 15...

Страница 16: ...COLOR WHEEL 16...

Страница 17: ...STATIC GOBO WHEEL 17...

Страница 18: ...any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps ca...

Страница 19: ...d on the bottom of the unit and over the trussing system or a safe fixation spot Insert the end in the carabiner and tighten the safety screw CLAMP SAFETY CABLE FIXTURE INSTALLATION NOTICE The suitabl...

Страница 20: ...by a skilled person once a year SIDE MOUNTING TO MAINTAIN IP65 RATING INTEGRITY FIXTURE MUST BE INSTALLED WITH CABLES FACING THE GROUND AT ALL TIMES WATER MUST EASILY RUN OFF AND NOT COLLECT AROUND CA...

Страница 21: ...SEALED WITH A DIELECTRIC GREASE AVAILABLE AT MOST ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE...

Страница 22: ...ed to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Hydro BeamX2 can be controlled via DMX 512 protocol Your unit and yo...

Страница 23: ...etting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set...

Страница 24: ...on until the required function is displayed on the monitor Select the function by pressing the ENTER button Use the UP DOWN button to navigate the submenu then press the ENTER button to store selectio...

Страница 25: ...All Reset Yes No Reset All Motors Pan Tilt Reset Yes No Reset the Pan Tilt Motors Color Reset Yes No Reset the Color Wheel Motor Gobo Reset Yes No Reset the Gobo Wheel Motors Frost Reset Yes No Reset...

Страница 26: ...ead Temperature Max Resettable Reset Base Temp Yes No Pass Code 050 Reset Base Temperature Max Resettable Humidity Head Humidity XXX Current Head Humidity Base Humidity XXX Current Base Humidity Fan I...

Страница 27: ...N button to select DMX Wifly or Wifly and DMX Out press the ENTER button to store Use the UP DOWN button to select No or Yes and press the ENTER button to store Press the MENU button to go back to the...

Страница 28: ...exit menu mode Gobo Reset Select Gobo Reset and press the ENTER button to confirm Use the UP DOWN button to select No or Yes and press the ENTER button to store Press the MENU button to go back to th...

Страница 29: ...to go back to the last menu or let the unit idle 30 seconds to exit menu mode USB Software Update Software Select Update Software and press the ENTER button to confirm Use the UP DOWN button to selec...

Страница 30: ...on to confirm Use the UP DOWN button to select Fixture Errors or Reset Error Logs and press the ENTER button to store Select Reset Error Logs and press the ENTER button to confirm Use the UP DOWN butt...

Страница 31: ...commended to Install devices a minimum of 9 8 ft 3m above audiences and or ground level Adjust the wireless antenna in a vertical upright position Position devices in direct line of sight of the contr...

Страница 32: ...d 064 065 Red 066 067 Red to Orange 068 069 Orange 070 071 Orange to Aqua Marine 072 073 Aqua Marine 074 075 Aqua Marine to Green 076 077 Green 078 079 Green to Light Green 080 081 Light Green 082 083...

Страница 33: ...Fast 080 083 Gobo6 Shaking Slow to Fast 084 087 Gobo7 Shaking Slow to Fast 088 091 Gobo8 Shaking Slow to Fast 092 095 Gobo9 Shaking Slow to Fast 096 099 Gobo10 Shaking Slow to Fast 100 103 Gobo11 Shak...

Страница 34: ...0 11 14 Focus 000 255 0 100 15 Focus Fine 000 255 0 100 12 16 Frost 000 007 Close 008 255 Open 13 17 Pan Tilt Speed 000 255 Fast to Slow 14 18 Special Function 000 069 Null 070 079 Enable Blackout Whi...

Страница 35: ...ff Lamp Hot Power Off 20 Lamp On Error Lamp On Error 21 Lamp Volt Too High Lamp Volt Too High 22 Ballast Temp High Ballast Temp High 23 Lamp Maintenance Lamp Maintenance 24 Head Humidity Error Head Hu...

Страница 36: ...ad Fan 4 Cannot Start 57 HeadFan41 Stop Err Head Fan 4 Cannot Stop 58 HeadFan4 Too Low Head Fan 4 Speed Too Low 59 HeadFan4 Too High Head Fan 4 Speed Too High 60 headFan5 Start Err Head Fan 5 Cannot S...

Страница 37: ...MPS CLEANING Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth t...

Страница 38: ...ms 6 facet linear and 24 facet circular Bidirectional prism rotation for each prism Prisms can be overlayed Control Configurable via RDM Controllable via DMX512 2 DMX Channel Modes 14 18 Channels Colo...

Страница 39: ...DIMENSIONS 39...

Страница 40: ...io communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can...

Страница 41: ......

Отзывы: