nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 5P Hex 

 

                                                     Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ Products, LLC part number Z-DMX/T) will decrease the possibili-

ties of erratic behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

ADJ Products, LLC  -  www.adj.com  - 5P Hex User Manual Page 7

ADJ Products, LLC  -  www.adj.com  - 5P Hex User Manual Page 6

  5P Hex                                             Operating Instructions

Control Panel Lock:

The control panel will lock itself after 30 seconds if nothing is 

pressed. To unlock the control panel, press the MODE button 

for 3 seconds.

Operating Modes:

The 5P Hex has five operating modes:

•  DMX control mode - This function will allow you to control each

  individual fixtures traits with a standard DMX 512 controller.

 

•  RGBWA + UV Mode - Choose one of the six colors to remain static  

  or adjust the intensity of each color to make your own color. 

•  Sound-Active mode - The unit will react to sound, chasing through  

 the built in programs. The sound sensitivity is adjustable

•  Program Mode - There are 7 built-in programs to choose from.   

  Color change and color fade speeds are adjustable.

•  Static Color Mode - There are 63 colors to choose from.

DMX Mode:

Operating  through  a  DMX  controller  gives  the  user  the  freedom  to 

create  their  own  programs  tailored  to  their  own  individual  needs. 

The 5P Hex has 4 DMX modes: 6 Channel mode, 7 Channel mode, 

8 Channel mode, and a 12 Channel mode. See pages 13-16 for each 

modes’ DMX traits.

1.  This function will allow you to control each individual fixture’s   

  traits with a standard DMX 512 controller.

2.  To run your fixture in DMX mode press the MODE button until   

  “AXXX” is displayed. “XXX” represents the current displayed ad-

  dress. Use the UP or DOWN buttons to select your desired DMX  

  address, then press the SETUP button to select your DMX 

  Channel mode. 

3.  Use the UP or DOWN buttons to scroll through the DMX Channel  

  modes. The Channel modes are listed below:

  •   To run the 6 Channel Mode, press the MODE button until “Ch06”  

  is displayed. This is the 6 Channel DMX Mode.

  •  To run the 7 Channel Mode, press the MODE button until “Ch07”  

  is displayed. This is the 7 Channel DMX Mode.

  •  To run the 8 Channel Mode, press the MODE button until “Ch08”  

  is displayed. This is the 8 Channel DMX Mode.

Содержание 5P HEX

Страница 1: ...ademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical da...

Страница 2: ...led in a place where it is out of the reach of people s grasp 5P Hex Installation 5P Hex Introduction ADJ Products LLC www adj com 5P Hex User Manual Page 2 Unpacking Thank you for purchasing the 5P H...

Страница 3: ...r Supply The ADJ 5P Hex contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct powe...

Страница 4: ...ersion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Do Not Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5...

Страница 5: ...the highest Program Mode In this mode you can choose 1 of 7 programs to run The fade speed and program speed are both adjustable 1 Plug the fixture in and press the MODE button until P XX is dis playe...

Страница 6: ...sockets The quantity that can be connected is 8 fixtures maximum for 120V and 21 fixtures maximum for 240V After the maximum fixtures has been reached you will need to use a new power outlet They mus...

Страница 7: ...ate the built in programs mode Use the and buttons to scroll through the 7 programs and find your desired program SOUND ACTIVE This button activates sound active mode AUTO RUN When in program mode pre...

Страница 8: ...X Values Functions 5P Hex 12 Channel DMX Values Functions Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 AMBER 0 255 0 100 6 UV 0 255 0 100 7 MAS...

Страница 9: ...B W A 4 7 Red 68 71 B A 132 135 G B A 196 199 R B W UV 8 11 Green 72 75 B UV 136 139 G B UV 200 203 R B A UV 12 15 Blue 76 79 W A 140 143 G W A 204 207 R W A UV 16 19 White 80 83 W UV 144 147 G W UV 2...

Страница 10: ...the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in whi...

Страница 11: ...specified above ADJ Products LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in m...

Страница 12: ...nnel Mode 8 Channel Mode 11 Channel Mode 12 Channel Mode Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without a...

Отзывы: