background image

Master-Slave Configuration:

 

This function will allows you to link units together to run in a Master-

Slave mode. In Master-Slave operation one unit will act as the con-

trolling unit and the others will react to the controlling units built-in 

programs. Any unit can act as a Master or as a Slave however, only 

one unit can be programmed to act as the “Master.” 
Master-Slave Connections and Settings:

1.   Daisy chain your units via the XLR connector on the rear of the 

  unit. Use standard XLR data cables to link your units together.  

    Remember that the Male XLR connector is the input and the   

  Female XLR connector is the ouput. The first unit in the chain 

  (master) will use the female XLR connector only. The last unit in  

  the chain will use the male XLR connector only. 

2.   Set the “Master” unit to your desired mode of operation. 

3.   Connect the first “Slave” unit to the “Master.”

4.   On the “Slave” unit press the MODE button until “SLAv” is dis- 

    played. The “Slave” unit will now follow the “Master”.

  5P Hex                                     Master-Slave Configuration 

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the I.E.C input and output sockets. The quantity that can 

be  connected  is  8  fixtures  maximum  for  120V  and  21  fixtures 

maximum for 240V. After the maximum fixtures has been reached 

you will need to use a new power outlet. They must be the same 

fixtures. DO NOT mix fixtures.

  5P Hex                                          Power Cord Daisy Chain

  5P Hex                                             Operating Instructions

the fixture will go into when the DMX signal is lost. You can also set this 

as the operating mode you would like the unit to return to when power 

is applied.  

1.   Press the MODE button until the DMX address is displayed. Press  

      the ENTER button until either “Soun”, “HOLd”, or “blC” is dis-        

      played.
2.   Use the UP or DOWN buttons to find the mode you want incase  

      of power loss or DMX loss.
• “blC” (Blackout) - If the DMX signal is lost or interrupted, the unit will 

automatically go into stand by mode.
• “HOLd” (Last State) - If the DMX signal is lost or interrupted, the fix-

ture will stay in the last DMX set up. If power is applied and this mode 

is set, the unit will automatically go into the last DMX set up.   
• “Soun” (Sound Active) - If the DMX signal is lost or interrupted, the 

unit will automatically go into sound active mode.
3.   Find your desired setting and press ENTER. Your setting will be  

      saved automatically.

ADJ Products, LLC  -  www.adj.com  - 5P Hex User Manual Page 11

ADJ Products, LLC  -  www.adj.com  - 5P Hex User Manual Page 10

Содержание 5P HEX

Страница 1: ...ademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical da...

Страница 2: ...led in a place where it is out of the reach of people s grasp 5P Hex Installation 5P Hex Introduction ADJ Products LLC www adj com 5P Hex User Manual Page 2 Unpacking Thank you for purchasing the 5P H...

Страница 3: ...r Supply The ADJ 5P Hex contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct powe...

Страница 4: ...ersion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Do Not Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5...

Страница 5: ...the highest Program Mode In this mode you can choose 1 of 7 programs to run The fade speed and program speed are both adjustable 1 Plug the fixture in and press the MODE button until P XX is dis playe...

Страница 6: ...sockets The quantity that can be connected is 8 fixtures maximum for 120V and 21 fixtures maximum for 240V After the maximum fixtures has been reached you will need to use a new power outlet They mus...

Страница 7: ...ate the built in programs mode Use the and buttons to scroll through the 7 programs and find your desired program SOUND ACTIVE This button activates sound active mode AUTO RUN When in program mode pre...

Страница 8: ...X Values Functions 5P Hex 12 Channel DMX Values Functions Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 AMBER 0 255 0 100 6 UV 0 255 0 100 7 MAS...

Страница 9: ...B W A 4 7 Red 68 71 B A 132 135 G B A 196 199 R B W UV 8 11 Green 72 75 B UV 136 139 G B UV 200 203 R B A UV 12 15 Blue 76 79 W A 140 143 G W A 204 207 R W A UV 16 19 White 80 83 W UV 144 147 G W UV 2...

Страница 10: ...the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in whi...

Страница 11: ...specified above ADJ Products LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in m...

Страница 12: ...nnel Mode 8 Channel Mode 11 Channel Mode 12 Channel Mode Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without a...

Отзывы: