4.1.2.3
Basic configuration “Extended 2”
In the “Extended 2” basic configuration, the following limit values are set as default during
factory configuration.
Index
Detection
variable
Limit value combinations
1
2
3
4
5
2
H
2
50
20
0
3
–
9
HC
–
–
25
10
–
1
CO
20
80
20
30
–
10
NO
X
–
–
–
–
–
4.1.2.4
Basic configuration “Robust”
In the “Robust” basic configuration, the following limit values are set as default during factory
configuration.
Index
Detection
variable
Limit value combinations
1
2
3
4
5
2
H
2
90
90
50
50
–
9
HC
–
–
10
20
–
1
CO
40
20
50
20
–
10
NO
X
–
–
–
–
–
The “Robust” basic configuration is exclusively suited for operation
within closed, non-vented enclosures (e.g. silos or bunkers)!
The free volume
within the enclosure should not exceed 10 m³!
4.1.2.5
Basic configuration “Individual”
If an application environment requires limit value combinations deviating from the “Standard”,
“Extended” and “Robust” basic configurations, a set of individual limit value combinations can
be programmed as factory configuration upon request. In such cases, the basic configuration
is referred to as “Individual”.