13
Never charge batteries with a non-suitable
charger. Strictly follow the instructions
supplied by the batteries and recharger
manufacturer.
In order not to cause permanent damages to the
batteries, never leave them completely
discharged, providing for their immediate
recharging. In case of stops of more than two
weeks of the machine, take off the battery
connector (see under “CONNECTION BATTERIES”).
BATTERIES DISPOSAL
It is mandatory to hand over exhausted batteries,
classified as dangerous waste, to an authorized
institution according to the current laws.
RECOVERY TANK
Check that the cover of the suction filter (17) is
correctly secured, after rotating the levers (B).
Furthermore, check that the squeegee hose is
correctly seated in its seat (A).
SOLUTION TANK
The capacity of the solution tank is indicated in
the technical data.
Open the screw plug (15) situated on top and fill
the solution tank with clean water at a maximum
temperature of 50°C. Add the liquid detergent in
the percentage recommended by the
manufacturer. To avoid excessive foaming, which
could cause problems to the suction motor, use
the minimum percentage of detergent. Screw
down the plug to close the tank.
Use always low foam detergent. To avoid
excessive foaming, before starting working
operation, add into the recovery tank a minimum
quantity of anti-foam product.
Never use acid.
FLOOR CLEANING
STARTING OF THE MACHINE
The push buttons on the instrument board are
lighted with an upper green signal LED that
shows the activation of each control.
1.
Switch on the machine pressing the on/off
switch (1).
2.
Check the battery charge level (see under
“BATTERY CHARGING”).
3.
Lower the squeegee by rotating downwards
the handle of the squeegee lifting lever (5)
placed in the centre of the handle bar.
4.
Press the switch for the brush motor (2).
5.
Press the switch for the suction motor (3).
6.
Press the switch for the solenoid valve (4).
7.
The machine is equipped with a solenoid
valve, which activates the solution flow
automatically when the scrub control levers
(7) are engaged. Releasing these levers will
stop the flow automatically.
8.
Activating the levers (7) the brush will start
rotating. The solution flow begins and the
squeegee will start drying the floor.