background image

 

 

 

 

13 

 

 

 

 

Never charge batteries with a non-suitable 

charger. Strictly follow the instructions 

supplied by the batteries and recharger 

manufacturer. 

 

 

In order not to cause permanent damages to the 

batteries, never leave them completely 

discharged, providing for their immediate 

recharging. In case of stops of more than two 

weeks of the machine, take off the battery 

connector (see under “CONNECTION BATTERIES”). 

 

BATTERIES DISPOSAL 

It is mandatory to hand over exhausted batteries, 

classified as dangerous waste, to an authorized 

institution according to the current laws. 

 

RECOVERY TANK 

Check that the cover of the suction filter (17) is 

correctly secured, after rotating the levers (B). 

Furthermore, check that the squeegee hose is 

correctly seated in its seat (A). 

 

 

 

SOLUTION TANK 

The capacity of the solution tank is indicated in 

the technical data. 

Open the screw plug (15) situated on top and fill 

the solution tank with clean water at a maximum 

temperature of 50°C. Add the liquid detergent in 

the percentage recommended by the 

manufacturer. To avoid excessive foaming, which 

could cause problems to the  suction motor, use 

the minimum percentage of detergent. Screw 

down the plug to close the tank. 

 

 

 

 

Use always low foam detergent. To avoid 

excessive foaming, before starting working 

operation, add into the recovery tank a minimum 

quantity of anti-foam product. 

Never use acid. 

 

 

FLOOR CLEANING 

 

STARTING OF THE MACHINE 

The push buttons on the instrument board are 

lighted with an upper green signal LED that 

shows the activation of each control. 

1.

 

Switch on the machine pressing the on/off 

switch (1). 

2.

 

Check  the battery charge level  (see under 

“BATTERY CHARGING”). 

3.

 

Lower the squeegee by rotating downwards 

the handle of the squeegee lifting lever (5) 

placed in the centre of the handle bar. 

4.

 

Press the switch for the brush motor (2). 

5.

 

Press the switch for the suction motor (3). 

6.

 

Press the switch for the solenoid valve (4). 

7.

 

The machine is equipped with a solenoid 

valve, which activates the solution flow 

automatically when the scrub control levers 

(7) are engaged.  Releasing these levers will 

stop the flow automatically. 

8.

 

Activating the levers (7) the brush will start 

rotating. The solution flow begins and the 

squeegee will start drying the floor. 

Содержание baby

Страница 1: ...baby baby plus XFC baby plus Li 07 2016 Use and maintenance Attention Please read the instructions before use...

Страница 2: ...ank L 16 16 16 Machine length min mm 745 745 745 Machine height mm 550 550 550 Machine width mm 415 415 415 Machine weight empty with batteries kg 60 70 53 Weight before operation kg 81 86 68 Weight o...

Страница 3: ...disposal 5 Correct use 5 Maintenance 5 LEGEND INSTRUMENT BOARD AND CONTROLS 6 LEGEND MACHINE 6 SYMBOLOGY MACHINE 7 SYMBOLOGY HANDBOOK 7 BEFORE USE 8 Handling of the packed machine 8 Unpacking of the...

Страница 4: ...19 TROUBLESHOOTING GUIDE 19 The suction motor does not work 19 The brush motor does not work 20 Insufficient water on the brush 20 The machine does not clean properly 20 The squeegee does not dry per...

Страница 5: ...components and considering that the machine itself has been where possible constructed using recyclable materials CORRECT USE Do not use the machine on surfaces covered with inflammable liquids or du...

Страница 6: ...LEVER 6 HANDLE BARS 7 SCRUB CONTROL LEVERS 8 HANDLE BAR RELEASE LEVER LEGEND MACHINE 9 WHEELS 10 BRUSH BASE ASSEMBLY 11 SOLUTION FLOW ADJUSTMENT 12 SOLUTION TANK 13 DRAIN PLUG SOLUTION TANK 14 SQUEEG...

Страница 7: ...es Symbol denoting the crossed bin Indicates that at the end of its activity the machine has to be disposed conforming to the laws in force SYMBOLOGY HANDBOOK Symbol denoting the open book Indicates t...

Страница 8: ...ions 1 Pull up the release lever 8 near the handle bars 2 Rotate the handle bar into the working position while holding the release lever 8 3 Let go of the release lever 8 to lock the handle bar Use t...

Страница 9: ...containing the present use and maintenance Insert the connector 1 into the other one 2 fixed to the battery cables of the machine If a longer stop of the machine is expected take off the connector 1...

Страница 10: ...t then take it off To reassemble everything repeat the above indicated procedure inversely DISASSEMBLY OF THE BATTERIES VERSION PLUS WITH XFC BATTERIES To disassemble the batteries from the machine it...

Страница 11: ...or 1 2 Unscrew the wing nuts 2 take off the support 3 and take off the battery 4 To reassemble everything repeat the above indicated procedure inversely BATTERY CHARGING STANDARD VERSION WITH AGM BATT...

Страница 12: ...ated battery charger There is a phase in which the green led of the general switch 1 starts to blink This is the best condition to carry out the battery recharging When the led becomes red this means...

Страница 13: ...e manufacturer To avoid excessive foaming which could cause problems to the suction motor use the minimum percentage of detergent Screw down the plug to close the tank Use always low foam detergent To...

Страница 14: ...in the desired position Once the obstacle has been passed and the manoeuvre completed repeat the operation to return to the previous working position This operation is possible also with the machine...

Страница 15: ...floor re establishes immediately its normal functioning STOPPING THE MACHINE AFTER CLEANING OPERATION Before carrying out any type of maintenance 1 Switch off the on off switch 1 2 Lift the squeegee...

Страница 16: ...Clean all parts with a water jet and especially the surfaces and the filter bottom 4 Carry out carefully the cleaning operations 5 Reassemble everything VERTICAL POSITIONING OF THE MACHINE The machine...

Страница 17: ...the brush clockwise as indicated in the figure until it is released from their seats of the brush holder plate 3 To reassemble the brush insert the coupling buttons into the slots of the brush holder...

Страница 18: ...unctionality of the machine it is necessary to replace the brush see under BRUSH REMOVAL FITTING BRUSH REPLACEMENT The brush has to be replaced when the control device brush wear intervenes It is poss...

Страница 19: ...membering to switch off the on off switch and to empty the tanks 3 With the machine in this position take off the squeegee and then the rear squeegee rubber see under REAR SQUEEGEE RUBBER REPLACEMENT...

Страница 20: ...level of the liquid in the solution tank see under SOLUTION TANK 3 Check that the solution flow adjuster 11 placed in front underneath the solution tank is sufficiently open 4 Press the brush control...

Страница 21: ...or is not very dirty In this case please dilute detergent solution LED 2 3 AND 4 BECOME RED If the machine is in the driving sense with the general switch 1 on and one of the three led 2 3 or 4 change...

Страница 22: ...22...

Страница 23: ...ore easily and deeper Please be aware that when brush bristles are worn out they become rigid and unable to penetrate and clean deeper This may also cause brush vibration with thicker bristles PAD HOL...

Страница 24: ...nte Pastello 14 I 37057 San Giovanni Lupatoto VR Tel 39 045 877 9086 Fax 39 045 877 9195 Logistics and Production Via Saturno 25 I 37059 S Maria di Zevio VR Tel 39 045 606 6289 Fax 39 045 605 0903 www...

Отзывы: