CHARACTERISTICS:

 

 

The HD67C56-B2 is a EnOcean / BACnet Slave Converter. 

 

It allows the following characteristics: 

 

Electrical isolation between BACnet and Power Supply; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 18…35V DC and 8…24V AC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 
CONFIGURATION: 
 

You need Compositor SW67C56 software on your PC in order to perform the following: 

 

Define the parameter of BACnet line; 

 

Define the parameter of EnOcean line; 

 

Define the list of BACnet objects accessible by the BACnet Master; 

 

Update the device. 

Содержание HD67C56-IP-B2

Страница 1: ...onverter EnOcean to www adfweb com Product HD67C50 Serial www adfweb com Product HD67C52 Modbus Slave www adfweb com Product HD67C54 Modbus TCP Slave www adfweb com Product HD67C57 CAN www adfweb com...

Страница 2: ...NTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Rela...

Страница 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean BACnet Slave Document code MN67C56_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean BACnet Slave Document code MN67C56_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67C56 IP B2...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean BACnet Slave Document code MN67C56_ENG Revision 1 000 Page 6 of 30 Figure 1b Connection scheme for HD67C56 MSTP B2...

Страница 7: ...stics Electrical isolation between BACnet and Power Supply Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You...

Страница 8: ...NG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Страница 9: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Страница 10: ...green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 EnOcean communication yellow Blinks when EnOcean data is received Blinks quickly Boot state Blinks very...

Страница 11: ...communication The Ethernet connection must be made using Connector2 of HD67C77 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to...

Страница 12: ...metering and lighting Each device uses a unique ID for identification and one of the standardized profiles EEPs for data transmission Communication process may be secure or unsecure and may be unidire...

Страница 13: ...put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Beld...

Страница 14: ...Converter use the available software that runs with Windows called SW67C56 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Wind...

Страница 15: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable EnOcean BACnet Slave Converter in order to configure another device in the same manner...

Страница 16: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Страница 17: ...nOcean BACnet Slave Document code MN67C56_ENG Revision 1 000 Page 17 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Страница 18: ...n the fields SUBNET Mask the SubNet Mask of BACnet IP side of the converter is defined In the fields GATEWAY the default gateway of the network is defined This feature can be enabled or disabled press...

Страница 19: ...ld Max Info Frames specifies the maximum number of information frames the node may send before it must pass the token In the field Device Instance the of the BACnet MS TP side of the converter is defi...

Страница 20: ...de MN67C56_ENG Revision 1 000 Page 20 of 30 Figure 4 EnOcean Access window ENOCEAN ACCESS By Pressing the EnOcean Set Access button from the main window for SW67C56 Fig 2 the window EnOcean Set Access...

Страница 21: ...device is defined In the field Secure Type the type of EnOcean communication is defined In the field Key the key used for encryption of frames in Secure Mode is defined In the field Rolling Code the...

Страница 22: ...ds are In the field Rorg the type of EnOcean telegram is defined In the field Func the type of EnOcean instance is defined In the field Type the type of event is defined The means of the Variable fiel...

Страница 23: ...ns the BACnet objects writeable by a BACnet Master EnOcean data written The meaning of the fields in the window are the follows In the field Data Type is possible to select the BACnet object data type...

Страница 24: ...piling the Selected BACnet Engineering Unit field or by selecting with the fields Select the Type and Select unit the Type Unit desired If the second way is used is necessary to press the Select Engin...

Страница 25: ...et cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of...

Страница 26: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mo...

Страница 27: ...trial Electronic Devices ADFweb com S r l User Manual EnOcean BACnet Slave Document code MN67C56_ENG Revision 1 000 Page 27 of 30 Figure 11 Mechanical dimensions scheme for HD67C56 B2 MECHANICAL DIMEN...

Страница 28: ...Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting BACnet Type IP BACnet IP MSTP BACnet MS TP Device Family HD67C56 EnOcean BACnet Slave Converter Order Code HD67C56 IP B2...

Страница 29: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Страница 30: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to t...

Отзывы: