Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
PROFIBUS Master
/ MQTT
Document code: MN67950_ENG Revision 1.000 Page 16 of 36
Figure 3d: “Set Communication
Ethernet”
window
Figure 3g: “Set Communication
TLS” window
In the field “
Username
” the username for the connection to the MQTT server is defined;
In the field “
Password
” the password for the connection to the MQTT server is defined.
E
THERNET
:
This section is used to define the general parameters of Ethernet. The means of the
fields are:
In the field “
Ip Address
” the IP address of the converter is defined;
In the field “
SubNet
Mask
” the Subnet Mask of the converter is defined;
In the field “
Gateway
” the default gateway of the net is defined. This
feature can be enabled or disabled pressing the Check Box field. This feature
is used for going out of the net;
In the field “
DNS
” the DNS address is defined. This field is required if the
server address is define by URL and not IP Address.
TLS
(T
RANSPORT
L
AYER
S
ECURITY
):
This section is used to define the parameters of TLS protocol. The means of the
fields are:
If the field “
Enable TLS
” is checked, the TLS protocol for secure connection
is enabled;
If the field “
Server Authentication
” is checked, the authentication of the
Server using TLS is enabled. If enabled, in the field “
Server Certificate
” the
certificate from the Server is defined;
If the field “
Client Authentication
” is checked, the authentication of the
Client using TLS is enabled. If enabled:
o
in the field “
Client Certificate
” the certificate from the Client is
defined;
o
in the field “
Client Key
” the private key of the Client is defined;
o
in the field “
Client Key
Password
” the password for the private key of the Client is defined.