IEC61850 Client / PROFIBUS Slave 

 

Document code: MN67777_ENG     Revision 1.000    Page 26 of 28

 

 

 
ORDERING INFORMATIONS: 

 
The ordering part number is formed by a valid combination of the following:  

HD67777 – A 1 

 
 

 

 

 

Connectors Type 

 

 

 

 

1: Removable 5mm Screw Terminal 

 
 

 

 

 

Enclosure Type 

A: 1M, 35mm DIN Rail mounting 

 

 

 

 

Device Family 

 

 

 

 

HD67777: IEC61850 Client / PROFIBUS Slave - Converter 

 
 

Order Code: 

HD67777-A1 

-  

IEC61850 Client / PROFIBUS Slave - Converter 

 

 
 

ACCESSORIES: 

 
Order Code: 

AC34011      - 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC  

Order Code: 

AC34012 

Rail

 

DIN - Power Supply 220/240V AC 50/60Hz – 24 V DC 

Содержание HD67750-A1

Страница 1: ...duct HD67E14 EtherCAT www adfweb com Product HD67765 Modbus Slave www adfweb com Product HD67766 Modbus TCP Slave www adfweb com Product HD67767 BACnet Slave www adfweb com Product HD67768 CAN www adf...

Страница 2: ...TIES AND TECHNICAL SUPPORT 28 RETURN POLICY 28 Pagina 2 di 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document i...

Страница 3: ...rlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Страница 4: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 4 of 28 EXAMPLE...

Страница 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1...

Страница 6: ...characteristics Two directional information between PROFIBUS and IEC61850 Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CON...

Страница 7: ...t PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin V...

Страница 8: ...e device has got two functions mode depending of the position of the Dip2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second wi...

Страница 9: ...F Device not powered 2 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IEC61850 comm green It blinks when a IEC 61850 response is received...

Страница 10: ...Ethernet connection must be made using Connector3 or Connector4 of HD67777 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the...

Страница 11: ...91 31 User Manual IEC61850 Client PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 11 of 28 PROFIBUS The PROFIBUS uses a 9 pin D SUB connector The pin assignment is defined like in the rig...

Страница 12: ...ter use the available software that runs with Windows called SW67777 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Страница 13: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC61850 Client PROFIBUS Slave Converter in order to c...

Страница 14: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Страница 15: ...0438 30 91 31 User Manual IEC61850 Client PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s comman...

Страница 16: ...SubNet Mask for IEC61850 side of the converter is defined In the fields Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This fea...

Страница 17: ...e Document code MN67777_ENG Revision 1 000 Page 17 of 28 Figure 4 IEC61850 Client Set Access window IEC61850 ACCESS By Pressing the IEC61850 Access button from the main window for SW67777 Fig 2 the wi...

Страница 18: ...nal structure By clicking on ADD IEC Device it is possible to add a new IEC61850 Server A SCL file has to be selected the allowed extensions are scd ssd sed icd iid or cid The functional structure of...

Страница 19: ...the IEC61850 variable is defined In the field fc the Functional Constraint of the IEC61850 variable is defined In the field Reference the path of the IEC61850 variable is defined In the field Start By...

Страница 20: ...delay in ms between two readings writings of the variable is defined if On Timer is checked In the field Position the starting byte of the internal memory arrays where saving getting the value is def...

Страница 21: ...hich the IEC61850 Dataset belongs is defined In the field Reference the path of the IEC61850 Dataset is defined In the field Goose Name the Goose Name of the IEC61850 Dataset is defined if En Goose is...

Страница 22: ...defined In the field Start Bit the starting bit of the byte of the field Position is defined only for BOOLEAN data In the field Conversion the type of conversion of the value is defined only for FLOA...

Страница 23: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations ar...

Страница 24: ...PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure th...

Страница 25: ...rl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client PROFIBUS Slave Document code MN67777_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 10 M...

Страница 26: ...g part number is formed by a valid combination of the following HD67777 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67777 IEC61850 Cli...

Страница 27: ...pean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appl...

Страница 28: ...sh to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information ab...

Отзывы: