background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

GSM I/O and Alarms Modem

 

 

Document code: MN67302_ENG     Revision 1.001   Page 14 of 35 

 

 

INPUT SETTING: 

 

D

IGITAL 

S

ETTING

 

The  device  has  two  Digital  Input.  For  both  of  them  it  is 
possible to do the same operations described in this section. 
 
There are two possibilities: 
 

 

Sending a SMS when the  Input changing from 0 to 1 

by  checking  the  field  “

Send  follow  SMS  when 

Digital Input change from value 0 to value 1

”; 

 
 
 
 

 

Sending a SMS when the  Input changing from 1 to 0 

by  checking  the  field  “

Send  follow  SMS  when 

Digital Input change from value 1 to value 0

”. 

 
 
 
 
For both cases there is the possibility to insert also different 
phone numbers and different SMS texts. 
 
For both cases the SMS will be sent only when the Input is to 
the other state for at least the time inserted in the field “

For 

a time major of ……… Milliseconds

”. 

 

 

Figure 9: “Input Setting 

 Digital” window

 

Содержание HD67302-B2 Series

Страница 1: ...mperature range 20 C 70 C 4 F 158 F Other Products Analyzer Scanner Sniffer M Bus www adfweb com Product HD67031 Multi Drop Converter RS232 RS485 to Optic Fiber www adfweb com Product HD67033M RS232 S...

Страница 2: ...customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document not...

Страница 3: ...anical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the in...

Страница 4: ...MacOS THE HARDWARE The device is available in three models These models differ in the type of Digital Input see ORDERING INFORMATIONS section THE SOFTWARE To obtain the software please go to www adfwe...

Страница 5: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual GSM I O and Alarms Modem Document code MN67302_ENG Revision 1 001 Page 5 of 35 USE OF COMPOSITOR SW67302 Fi...

Страница 6: ...1 31 User Manual GSM I O and Alarms Modem Document code MN67302_ENG Revision 1 001 Page 6 of 35 Figure 2 New Configuration window NEW CONFIGURATION By pressing the New Configuration button it is possi...

Страница 7: ...by selecting one of the list that appears A device configuration can also be imported or exported To clone the configurations of a GSM I O and Alarms Modem in order to configure another device in the...

Страница 8: ...67302_ENG Revision 1 001 Page 8 of 35 SAVE CONFIGURATION By pressing the Save Configuration button it is possible to save the project There are two possibilities or save the current configuration by p...

Страница 9: ...s the Update Device button to start the upload When all operations are OK the Configuration Firmware on the device is correctly updated For the updating the device must be on Boot Mode This modality i...

Страница 10: ...figuration or both of them Press the Update Device button to start the upload When all operations are OK turn Off the device Put the device at Normal Mode by Dip2 of Dip Switch A At this point the Con...

Страница 11: ...he correct one Check if the Cable is connected between the PC and the device Try to repeat the operations for the updating Try to use another USB port Try to restart the PC Try with another PC If you...

Страница 12: ...fweb com Phone 39 0438 30 91 31 User Manual GSM I O and Alarms Modem Document code MN67302_ENG Revision 1 001 Page 12 of 35 SOFTWARE PREFERENCES By pressing the Software Preferences button it is possi...

Страница 13: ...n 1 001 Page 13 of 35 PHONE SETTING By pressing the Phone Setting button it is possible to insert the PIN Code of the SIM Card Another thing that is possible to do is enable the Automatic switch of th...

Страница 14: ...es Sending a SMS when the Input changing from 0 to 1 by checking the field Send follow SMS when Digital Input change from value 0 to value 1 Sending a SMS when the Input changing from 1 to 0 by checki...

Страница 15: ...goes above a certain threshold voltage by checking the field Send follow SMS when Analog Input is Higher than Volt Sending a SMS when the Input goes below a certain threshold voltage by checking the...

Страница 16: ...e field SMS it is possible to enable the function of change the state of output using a SMS There are three possibilities SET output by SMS used for close the relay contact RESET output by SMS used fo...

Страница 17: ...of them are selected all numbers can perform an event Below there are some examples of the functioning with all cases It is possible to write also other words in the SMS the important thing is that t...

Страница 18: ...tput 1 sStO1 a None sRO1 a Reset Digital Output 1 Imp2 a None b 1234 SO1 RO1 IO1 1234 SO1 b Set Digital Output 1 RO1 1234 b Reset Digital Output 1 1234 IO1 b Impulse on Digital Output 1 Imp1 b None c...

Страница 19: ...he number of rings is under the value expressed in the field Ring Number Above Ring Number used for trigger an event if the number of rings is above the value expressed in the field Ring Number For al...

Страница 20: ...to make the operations all the time in a day DATE TIME In this section it is possible to change the Date Time of the device There are two possibilities Insert an own Date Time by compiling the fields...

Отзывы: