User Manual
Ethernet to RS232 / RS485
Document code: MN67038-2_ENG Revision 1.400 Page 11 of 25
O
PERATING
M
ODALITY
:
T
UNNEL
P
OINT TO
P
OINT
A mode that allows for the extension of a serial line using a Ethernet Network.
The two devices in this mode must be configured in a coherent way between
each one, or in such a way that both read the IP address of the other one.
It is necessary to insert the IP address of the remote device in addition to the
set-up of the device’s line.
The means of the fields for “Ethernet Configuration” are:
In the field “IP Address” the IP address of the Converter is defined;
In the field “SubNet Mask” the Subnet Mask of the Converter is defined;
In the field “Port” the Port of the Converter is defined;
In the field “Remote IP” the IP of the second device connected to the
same line is defined;
In the fields “TCP” and “UDP” the protocol of the communication is
defined;
In the field “Force socket TCP open” is defined if the socket TCP try to
connect to start up;
If the field “Use Gateway” is checked, in the field below it is possible to
insert the IP Address of the gateway used for going out to the net in the
field under;
The means of the fields for “Serial Configuration” are:
If you are using HD67038-2 or HD67038-2-M Converter, the field
“RS232” must be checked; instead if you are using HD67038-25 or
HD67038-25-M Converter, if the field “RS485” is checked the serial line
in use is the RS485 otherwise is the RS232;
In the field “BaudRate” the velocity of the serial line in use is defined;
In the field “Parity” the parity of the serial line in use is defined.
The button "ACTIVE SERIAL DRIVER" is used to activate the "Serial to Ethernet Connector". For more details go to page 17.
Figure 7: “General Parameter” window (Tunnel Point to Point)