Document code: MN67038-2_ENG Revision 1.400 Page 13 of 25
O
PERATING
M
ODALITY
:
T
UNNEL
P
OINT TO
M
ULTIPOINT WITH
B
ROADCAST
(S
LAVE
S
IDE
)
To
configure a device as Slave the field “Master Side” of “Operating
Modality” section must not be checked.
In the case of the slave it is necessary to provide the IP address of the
Master Converter.
The means of the fields for “Ethernet Configuration” are:
Select the “Work with Broadcast”, in this way the master sends the
messages in Broadcast;
In the field “IP Address” the IP address of the Converter is defined;
In the field “SubNet Mask” the Subnet Mask of the Converter is
defined;
In the field “Port” the Port of the Converter is defined;
In the field “Master IP” the IP address of the Master Converter is
defined.
The means of the fields for “Serial Configuration” are:
If you are using HD67038-2 or HD67038-2-M Converter, the field
“RS232” must be checked; instead if you are using HD67038-25 or
HD67038-25-M Converter, if the field “RS485” is checked the serial
line in use is the RS485 otherwise is the RS232;
In the field “BaudRate” the velocity of the serial line in use is
defined;
In the field “Parity” the parity of the serial line in use is defined.
The button "ACTIVE SERIAL DRIVER" is used to activate the "Serial to
Ethernet Connector". For more details go to page 17.
Figure 9: “General Parameter” window (Tunnel Point to Multipoint
Slave Side)