14
N.B. Periodically remove
collets and lubricate
seals with water.
44
1
Replace the collets,
quick release trigger
and canister.
45
1
Quick-release trigger
MagnaClean Professional3 Sense
incorporates a secure, quick-release, trigger which enables the filter
to be removed and re-installed in seconds. The connections enable easy and swift filter removal during
annual servicing or to undertake a
MagnaCleanse
system flush. This also makes it ideal for systems
where there is little room to install a filter.
The following instructions are designed to support engineers in the safe and effective servicing of
MagnaClean Professional3 Sense
using the quick-release trigger.
NOTE: Before following Quick-release trigger instructions ensure valves are closed and filter is
fully drained.
1
41
Fully unlock red
wheel from canister.
42
Disconnect.
1
43
1
Remove.
46
1
Lock red wheel
against canister.