Adexa EGG-16S Скачать руководство пользователя страница 9

6

 

Installation

 

Installation Requirements 

NOTE:

 

 

 

It is most important that this appliance is installed correctly and that operation is correct before 

use.  Installation shall comply with local gas, health and safety requirements.

 

 

 

This appliance shall be installed with sufficient ventilation to prevent the occurrence of 

unacceptable concentrations of substances harmful to health.

 

 

Our Gas Griddles are designed to provide years of satisfactory service and correct installation is essential to 
achieve the best performance, efficiency and trouble-free operation. 

 

This appliance must be installed in accordance with National installation codes and in addition, in accordance 

with relevant National / Local codes covering gas and fire safety. 

 

Installations must be carried out by qualified persons only.  Failure to install equipment to the 

relevant codes and manufacturer’s specifications shown in this section will void the warranty

 

Components having adjustments protected by the manufacturer are only to be adjusted by an 
authorized service agent. They are not to be adjusted by the installation person.

 

 

Unpacking

 

 

 

Remove all packaging and transit protection from the appliance including all protective plastic coating 

from the exterior stainless steel panels. 

 

Check equipment and parts for damage. Report any damage immediately to the carrier and distributor. 

 

Ensure that the 4 adjustable feet are fitted with the protruding centre screw. 

 

Report any deficiencies to the distributor who supplied the appliance. 

 

Check that the available gas supply is correct to that shown on the rating plate located on the right hand 

panel. 

 

Location

 

 

1.

 

Installation must allow for a sufficient flow of fresh air for the combustion air supply. 

2.

 

Installation must include adequate ventilation means, to prevent dangerous build-up of combustion 

products. 

3.

 

Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free 

operation. The minimum installation clearances shown below are to be adhered to. 

4.

 

Position the appliance in its approximate working position. 

5.

 

All air for burner combustion is supplied from underneath the unit.  The legs must always be fitted 

and no obstructions placed on the underside or around the base of the unit, as obstructions will 

cause incorrect operation and / or failure of the appliance. 

6.

 

Components having adjustments protected by manufacturer are only allowed to be adjusted by an 

authorized service agent. They are not to be adjusted by the installation person. 

Содержание EGG-16S

Страница 1: ...for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other app...

Страница 2: ......

Страница 3: ...sions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners...

Страница 4: ...IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF...

Страница 5: ...lure Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take s...

Страница 6: ...r s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in acco...

Страница 7: ...luded The Gas griddle Plate Four Feet Instruction Manual Flue baffle Product specification list Gas orifice dia Gas pres Total power EGG 48S EGG 36S EGG 24S EGG 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x...

Страница 8: ...5 Dimensions EGG 48S EGG 36S EGG 24S EGG 16S...

Страница 9: ...from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor...

Страница 10: ...label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubin...

Страница 11: ...gh the regulator Refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression f...

Страница 12: ...space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compa...

Страница 13: ...ed in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Install...

Страница 14: ...ration practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This app...

Страница 15: ...l knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will r...

Страница 16: ...in burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control...

Страница 17: ...riddle thoroughly with a dry cloth and polish with a soft dry cloth NOTE If the Griddle usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensur...

Страница 18: ...s control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a Good quality stainless steel cleaner or stainless ste...

Страница 19: ...rned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control...

Страница 20: ...ntact you re nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part...

Страница 21: ...18 Explosion Drawing EGG 48S...

Страница 22: ...ront panel 1 10 big steel foot 4 11 thermocouple 4 12 igniter pin with wire 4 13 U shape burner 4 14 thermocouple fixation plate 4 15 body shell 1 16 chimney 1 17 angle connector 4 18 sabaf gas valve...

Отзывы: