Adexa EGG-16S Скачать руководство пользователя страница 10

7

 

Installation

 

 

 

Clearances

 

NOTE:  Only non-combustible materials can be used in close proximity to this appliance. 

 

 

Combustible Surface

 

Non  Combustible  Surface

 

Left / Right Hand Side

Not applicable

150mm Min.

Rear 

Not applicable

150mm Min.

Bottom 

Not applicable

150mm Min.

Assembly 

NOTE:

 

 

This appliance is assembled before delivery except feet. 

 

 

This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level. 

 

 

Check all accessories complete. 

 

 

IM will be stated that the appliance shall be installed in such a way that side body surfaces are not 

accessible in the installed position. 

 

Gas Connection

 

 

NOTE:  ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.

 

 

1.

 

The Gas Griddle does not require an electrical connection, as they function totally on the gas supply 

only. 

2.

 

It is essential that the gas supply is correct for the appliance to be installed and that adequate 

supply pressure and volume are available.  The following checks should therefore be made before 

installation:- 

 

a.

 

Gas Type required for the appliance is shown in the rating label.  Check that this is correct for the gas 

supply the appliance is being installed for gas griddle; the gas conversion is not suited for gas griddle. 

 

b.

 

Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section of this 

manual. Check the gas supply to ensure adequate supply pressure exists. 

 

c.

 

Input Rate of this appliance is stated on the Rating label .The input rate should be checked against the 

available gas supply line capacity. Particular note should be taken if the appliance is being added to an 
existing installation. 

 

d.

 

The gas supply tubing or hose shall comply with the national requirements in force and shall be 

periodically examined and replaced as necessary. 

 

e.

 

 Only local national requirements rubber or PVC flexible hose (Nominal core of hose shall be 6.3mm 

to12.5mm) could be used for LP gas connection. The length of flexible hose shall not be more than 
1.5meters. The flexible hose shall not come into contact with sharp edges.   

 

f.

 

 LP Gas Regulator, flexible hose adaptor and rubber gasket shall be matched with local national 

requirements; A Manual Isolation Valve must be fitted to the individual appliance supply line. The 

regulator should be certificated according to EN16129 latest version. And the hose should be 
Certificated according to the latest version EN 16436-1, BSEN ISO3821, BSEN1327 or DIN 1763 

g.

 

 Nature gas shall be connected with from nature gas supply pipe to nature gas regulator and connection 

adaptor to match with local national installation requirements. The nature gas supply line must be at 
least the equivalent of ½” (12.7 mm) iron pipe for single units; A Manual Isolation Valve must be fitted 
to the individual appliance supply line. 

 

h.

 

The appliance should be connected to the gas supply by means of Flexible hose or metal pipes --either 

rigid or flexible-- having an adequate diameter. When joining pipe fittings, never use oakum or Teflon 

as their residues could get to the valve and jeopardize its operation. Instead, interpose a seal gasket 
suitable for use in gas systems.  

 

Содержание EGG-16S

Страница 1: ...for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other app...

Страница 2: ......

Страница 3: ...sions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners...

Страница 4: ...IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF...

Страница 5: ...lure Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take s...

Страница 6: ...r s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in acco...

Страница 7: ...luded The Gas griddle Plate Four Feet Instruction Manual Flue baffle Product specification list Gas orifice dia Gas pres Total power EGG 48S EGG 36S EGG 24S EGG 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x...

Страница 8: ...5 Dimensions EGG 48S EGG 36S EGG 24S EGG 16S...

Страница 9: ...from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor...

Страница 10: ...label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubin...

Страница 11: ...gh the regulator Refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression f...

Страница 12: ...space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compa...

Страница 13: ...ed in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Install...

Страница 14: ...ration practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This app...

Страница 15: ...l knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will r...

Страница 16: ...in burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control...

Страница 17: ...riddle thoroughly with a dry cloth and polish with a soft dry cloth NOTE If the Griddle usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensur...

Страница 18: ...s control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a Good quality stainless steel cleaner or stainless ste...

Страница 19: ...rned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control...

Страница 20: ...ntact you re nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part...

Страница 21: ...18 Explosion Drawing EGG 48S...

Страница 22: ...ront panel 1 10 big steel foot 4 11 thermocouple 4 12 igniter pin with wire 4 13 U shape burner 4 14 thermocouple fixation plate 4 15 body shell 1 16 chimney 1 17 angle connector 4 18 sabaf gas valve...

Отзывы: