SECTION 3: PROGRAMMING
THE VISTA 10
General
When access has been made to program mode, the system parameters can be changed
from the factory default settings. The default values for each of the parameters are
shown in brackets above each programming field. If no changes are made to these
defaults the system will operate as an audible only alarm.
Entering / Exiting Program Mode
To enter engineer mode: Enter engineer code + 8 + 0 + 0
.
If the engineer code has
been lost press the
Ö
+ # keys together within 30 seconds of powering up the sys-
tem. (No programming will be lost other than date and time).
To exit engineer mode: Enter
Ö
99. The default engineer code is
4110
. It is strongly
recommended that this code is changed by the engineer.
Programming Format
In engineer mode, the system programming can be modified using the
Ö
key or
viewed using the # key:
To programme a field: Enter
Ö
+ field field entry (in engineer mode).
e.g. to change the engineer code to
1111
enter
Ö
00 then
1111
, where 00 is the field
number for the engineer code. Two beeps indicate entry confirmed.
To view contents of a field: Enter # + field number (in engineer mode).
Each programming field on the following pages is shown preceded by
Ö
/#. This
indicates that the
Ö
key should be pressed to change the field or the # key should be
pressed to view the contents of the field. The
Ö
key also acts as an enter key when
entering less than the maximum number of digits for a particular field.
Defaults
To return the programming back to factory defaults: Enter
Ö
97. This will clear
all previous programming.
Note: It is not possible to default the master code without defaulting the complete
panel programming.
Software Version
To view which version of software the control panel is using, enter #92
in program
mode.
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA 10
Страница 2: ...2 www PDF Zoo com firealarmresources com...
Страница 15: ...15 Figure 2 2 Telephone Line Connections www PDF Zoo com firealarmresources com...
Страница 16: ...16 www PDF Zoo com firealarmresources com...
Страница 26: ...26 www PDF Zoo com firealarmresources com...
Страница 27: ...27 www PDF Zoo com firealarmresources com...
Страница 28: ...28 IE1 4110 ISSUE A 30 7 99 www PDF Zoo com firealarmresources com...