7845CZ Installation and Setup Guide
5–2
Table 5. 7845CZ Programming Defaults Summary for Zone Mode
PROGRAMMING OPTION
STANDARD DEFAULT
VALUE ACTUAL
ENTRY
1 City
*
xx
2 CS
ID
*
xx
3
Sub ID# *
xxxx
4 Supervision
24
hours
5 Time
Zone
Eastern
6 Carrier
Select
Auto
7
Flt Time (min)
5
8
Old Alarm Time
10 minutes
9
DC Loss Rpt
Y
10
Current Lim (Y/N)
N
11
Flt Rel On (Y/N)
N
12 Trigger
Type
EOLR
13
Lynx Panic (Y/N)
N
14
Tamper Rpt (Y/N)
Y
15
Invert Zn3 (Y/N)
N
16
Invert Zn4 (Y/N)
N
17
Invert Zn5 (Y/N)
N
18
Invert Zn6 (Y/N)
N
19
Invert Zn7 (Y/N)
N
20
Arm/Dis En (Y/N)
N
21
Delay Zn3 (secs)
00
22
Delay Zn4 (secs)
00
23
Delay Zn5 (secs)
00
24
Delay Zn6 (secs)
00
25
Delay Zn7 (secs)
00
26 Restore
Zn1(Y/N)
Y
27 Restore
Zn2(Y/N)
Y
28 Restore
Zn3(Y/N)
Y
29 Restore
Zn4(Y/N)
Y
30 Restore
Zn5(Y/N)
Y
31 Restore
Zn6(Y/N)
Y
32
Restore Zn7 (Y/N)
Y
33 Telco
Chan
00
34 Open/Close
00
35 2
nd
CS Rpt (Y/N)
N
Using a 7720P Programming Tool
The 7845CZ powers the 7720P Programming Tool via the programming jack.
NOTE: Some 7720Ps will not function when powered from the 6-volt battery in the 7845CZ.
In this case, the 7845CZ needs to be connected to a 12VDC source on TB1 in the control
panel.
Each key of the 7720P has two possible functions: a normal function and a Shift function. To
perform a normal key function, simply press the desired key. To perform a Shift function,
press the [SHIFT] key, and then press the appropriate key. For a description of each normal
and shift key function, refer to Table 6.
Содержание 7845CZ
Страница 2: ...7845CZZ Installation and Setup Guide ii...
Страница 8: ...viii...
Страница 38: ...7845CZ Installation and Setup Guide 5 12...
Страница 42: ...7845CZ Installation and Setup Guide 6 4...
Страница 50: ...7845CZ Installation and Setup Guide 8 4...
Страница 56: ...7845CZ Installation and Setup Guide 10 2...
Страница 64: ...l K4426CZ 9 01 165 Eileen Way Syosset NY 11791 Copyright 2001 PITTWAY CORPORATION...