![ADEMCO 7845CZ Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/ademco/7845cz/7845cz_installation-and-setup-manual_2850308015.webp)
4–1
S E C T I O N 4
Installation and Setup
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Removing the Cover
♦
Selecting a Radio Installation Site
♦
Initial Power-Up Sequence
♦
Testing the Installation
♦
Mounting and Wiring
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Removing the Cover
During normal operation, the cover of the 7845CZ
should remain in place.
To remove the cover, gently press in on the two locking
tabs and remove the cover.
Removing the cover triggers the following two events:
•
A tamper zone alarm is transmitted if the
7845CZ is registered and tamper reporting
has been enabled.
•
The RSSI bar graph, which is intended to
be used as an installation tool and
troubleshooting aid, becomes active.
LOCKING TAB
LOCKING TAB
See Figure 1 to identify the components of the 7845CZ.
7845CZ-001-V0
P2 ZONE
INPUTS
ZONE 3*
ZONE 4
ZONE 5
ZONE 6
ZONE 7
RADIO
STATUS
LEDs (3)
3
4
5
6
7
J2**
PROGRAMMING
PORT
J1
BATTERY
TB1
V+(12VDC)
GND
ZONE1, ZONE 2, ZONE 3* IN
RADIO FAULT OUT
TAMPER / TEST
SWITCH
ANTENNA
MIN
LABEL
RSSI
BARGRAPH
** CONNECT J2 TO 7720P PROGRAMMING TOOL ONLY!
DO NOT CONNECT TO TELEPHONE SYSTEM!
IF THE LYNX PANIC FEATURE IS BEING USED,
DO NOT CONNECT ZONE 3.
*
)LJXUH &= ZLWK &RYHU 5HPRYHG IRU &RPSRQHQW ,GHQWLILFDWLRQ
Содержание 7845CZ
Страница 2: ...7845CZZ Installation and Setup Guide ii...
Страница 8: ...viii...
Страница 38: ...7845CZ Installation and Setup Guide 5 12...
Страница 42: ...7845CZ Installation and Setup Guide 6 4...
Страница 50: ...7845CZ Installation and Setup Guide 8 4...
Страница 56: ...7845CZ Installation and Setup Guide 10 2...
Страница 64: ...l K4426CZ 9 01 165 Eileen Way Syosset NY 11791 Copyright 2001 PITTWAY CORPORATION...