background image

9,3

9LVWD,QWHUDFWLYH3KRQH0RGXOH

,QVWDOODWLRQDQG6HWXS*XLGH

®

N6431-3V1  10/99

Содержание 4286 VIP

Страница 1: ...9 3 9LVWD QWHUDFWLYH 3KRQH 0RGXOH QVWDOODWLRQ DQG 6HWXS XLGH N6431 3V1 10 99...

Страница 2: ......

Страница 3: ...ems with Alpha Keypads 3 5 Systems Using Only Fixed Word Keypads 3 5 Programming Note 3 5 Programming Relay Voice Descriptors 3 7 Programming Speaker Output Mode 3 9 Voice Menu for Programming Speaker...

Страница 4: ...hone Service A 1 FCC Statement Part 15 A 2 FCC Statement Part 68 A 2 TELECO Provided Coin Service Advisement A 3 TABLES TABLE 2 1 Wiring Connections 2 3 TABLE 3 1 4286 Zone Descriptors Vocabulary List...

Страница 5: ...dule can be used in a system 1 The 4286 VIP Module can only be used with systems using address able keypads Addressable keypads that may be used are 4137AD 5137AD 6128 6137 6138 and 6139 2 For control...

Страница 6: ...used for security system access must have Touch tone capability Switchable phones should be set for Touch tone temporarily before attempt ing phone access However an off premises phone that does not h...

Страница 7: ...capable of driving a loudspeaker providing system status warnings and confirmation of user commands Telephone programming mode for 4286 installation options 4286 VIP Module Specifications Physical 6 7...

Страница 8: ...4286 VIP Module Installation and Setup Guide 1 4...

Страница 9: ...Do not mount on the cabinet door or attempt to at tach it to the PC board The 4286 s cover can be left off if the Module is mounted within the cabinet To mount the 4286 outside the cabinet use the sc...

Страница 10: ...ated on back inside cover depending on whether other devices that connect to the telephone lines are also being used for example an Audio Alarm Verification unit Refer to the 4286 VIP Module section i...

Страница 11: ...if the system is not connected to a central station The 4286 will not operate properly if this is not done 3 If Touch tones are not present following access to the security system via an on premises...

Страница 12: ...4286 VIP Module Installation and Setup Guide 2 4...

Страница 13: ...necessary to remove and then re apply primary power to the Module as indicated in the information that follows the end of pro gramming on page 3 4 Programming The Control For 4286 VIP Module Usage It...

Страница 14: ...choed voice announcement You must wait for an echoed announcement and if satisfied with a field entry press to go on to the next field If you want to go back one field press If you do not need to prog...

Страница 15: ...ill monitor to control the 4500 thermostat and set its device address 01 to 31 in this field The selected keypad should be assigned to the partition where the 4500 thermostat is to be located With no...

Страница 16: ...mostat 1 enable 00 Thermostat 1 disabled 05 Thermostat 1 swing 1 4 0 0 deg F 1 0 deg F 06 Announce thermostat 1 temp 0 Do not announce 07 Thermostat 1 voice descriptor 1 000 No announcement 08 Thermos...

Страница 17: ...ors for Alpha key pad displays from those words listed in Table 3 1 on page 3 6 The words listed in Table 3 1 are those that are available in the 4286 VIP Module s own vocabulary and match many of the...

Страница 18: ...CE AREA ATTIC BABY BACK BAR BASEMENT BATHROOM BED BEDROOM BLOWER BOILER BRIGHT BUILDING CALL CENTRAL CLOSED COMPUTER DEN DETECTOR DINING DOOR DOWN DOWNSTAIRS DRIVEWAY DUCT EAST EQUIPMENT EXIT FACTORY...

Страница 19: ...ng the Relay Command Mode Synthesized voice feedback to verify status is possible with the 4286 VIP Module and with controls sup porting this Module Table 3 2 lists the words available in the Relay Vo...

Страница 20: ...1 DINING 016 DOOR 008 DOWN 184 DOWNSTAIRS 130 DRIVEWAY 131 DUCT 132 EAST 133 EQUIPMENT 004 EXIT 134 FACTORY 211 FATHER S 135 FENCE 040 FIRE 029 FLOOR 137 FOYER 087 FRONT 023 GARAGE 138 GAS 139 GLASS 0...

Страница 21: ...ol programming com plete all required entries or hang up the phone If the phone is hung up be fore the Phone Module announces Exiting then any changes made will be lost If a key other than 1 or 0 is p...

Страница 22: ...nouncement of a silent alarm Silent alarms are never an nounced Silent alarms are treated as faults as on a keypad MAIN KEYPAD 1 Yes 0 No Controls arming and other user command confirmations when the...

Страница 23: ...rogrammed for the 4286 VIP Module phone code device programming and the unit has been properly wired to the control panel and phone line the phone code must be set in the 4286 VIP by activating the mo...

Страница 24: ...DE NOW In some systems there will not be a voice prompt to enter the system code If no prompt is given key an OFF sequence system code plus OFF during or just after the status report to turn alarm off...

Страница 25: ...0 Key Function 1 OFF 2 AWAY 3 STAY 4 MAXIMUM 5 TEST 6 BYPASS 7 INSTANT 8 CODE 9 CHIME READY ON PREMISES PHONE ONLY IF PROGRAMMED 1 You CANNOT initiate a phone PANIC from the telephone keypad while in...

Страница 26: ...No synthesized voice announcement If desired you may exit during the Exit Delay period This function cannot be performed via the telephone with some controls check the control s Installation Instructi...

Страница 27: ...econds of the OUTGOING message on the answering machine preferably during a pause in the outgoing message before it begins recording an incoming message The reason for entry of the phone code during a...

Страница 28: ...on or off However field 80 Output Relay pro gramming must include System Operation choices 34 Code 7 and or 35 Code 8 for ZT Zone Type System Operation for a selected relay When so programmed the rela...

Страница 29: ...announced it would be assumed that help is needed and the 4286 will enter a novice mode The user will then be prompted to enter the 4 digit system code If there is no user response to the system code...

Страница 30: ...nd confirmation for Entry Exit Alarm and other warnings can also be provided The speaker output is for auxiliary use only and is not intended to replace the system s primary sounder or siren When usin...

Страница 31: ...phone code may be incor rect Verify phone code and try again Generally the system cannot be accessed when the phone line is busy such as when downloading is in progress if engaged in a phone conversat...

Страница 32: ...c Address in Field 01 Control Panel Type in Field 02 two digit phone code and panic code six 1 s have been entered correctly Both Field s 01 and 02 relate to the VIP Programming Mode There must be no...

Страница 33: ...lay the normal System Disarmed mes sage while an Alpha key pad will display Test in Progress unless a zone is faulted in which case the zone number and the description if it is an Alpha key pad of the...

Страница 34: ...If there is incorrect programming of RF zones for the 4281 or 5881 Re ceiver If more RF zones have been pro grammed than can be accommodated by the receiver in use an Alpha keypad will display RCVR Se...

Страница 35: ...gular phone service If the regular phone works correctly after the plug has been disconnected from the RJ31X CA38A in Canada wall jack the Control Panel or the 4286 VIP Module has a problem and the fa...

Страница 36: ...L COMMUNICATIONS COMMISSION FCC PART 68 STATEMENT This equipment complies with Part 68 of the FCC rules On the front cover of this equipment is a label that con tains among other information the FCC r...

Страница 37: ...ded coin service Connection to Party Line Service is subject to state tariffs This equipment is hearing aid compatible When programming or making test calls to emergency numbers briefly explain to the...

Страница 38: ...ERMINALS 3 AND 4 ON THE 4286 U S PATENT No 4791658 THIS DEVICE COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION No AC3USA 74659 KX N RINGER EQUIVALENCE 1 0B GREY BROWN GREEN RED EARTH GROUND TIP RING...

Страница 39: ...CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OW...

Страница 40: ...165 Eileen Way Syosset New York 11791 Copyright 1999 PITTWAY CORPORATION 1 9 Ql N6431 3V1 10 99...

Отзывы: