background image

 

2

Installation Instructions 

Residential Drinking Water Models 

DWS-2S-2710-01 

 

Your Drinking Water System has been tested to 
ensure it will operate correctly.  The following 
periodic maintenance is recommended so your 
system will provide years of trouble-free service: 
 

Replacement parts 
 
Cartridge #1 

            Cartridge #2 

 

SED001                       AD2710S 
5 Micron 

                  Arsenic 

 

Components 
 

The following components make up your Drinking 
Water System. 
 

#1 cartridge 

(sediment) removes 5 micron particles 

such as sand, silt, rust and scale. 
 

#2 cartridge

 reduces arsenic in the feed water. 

 

Filter housings

 holds the cartridges. A 

bracket 

is 

provided so they may be mounted, typically below 
the sink. 
 

Water Meter 

counts gallons filtered and 

automatically shuts the system off when capacity 
has been reached. 
 
The dedicated 

faucet

 is used to dispense filtered 

water when needed. 
 

Feed water saddle valve

 is connected to the cold 

water line to supply water to the system. 
 

Tubing

 supplies feed and filtered water. 

 

Fittings

 are used for necessary hose connections. 

 

Tools 

 
The following tools may be necessary, depending 
on each particular installation: 
 

 

3/8” variable speed electric drill; 1/8” &1/2” bits 

  1-1/4” porcelain hole cutter (if hole for second 

faucet is not provided). 

 

Center punch and hammer 

 

1-1/4” wood bit 

 

Concrete drill bits 

 

Phillips head and flat blade screwdrivers 

 Adjustable 

wrench 

 Crescent 

wrench 

 Teflon 

tape 

 Plastic 

tube 

cutter 

 

System location 
 

Your drinking water system may be installed under 
a sink, in a basement or other location, depending 
on available space.  Do not install unit where 
temperatures fall below freezing; otherwise, 
damage will result.  Connection to an icemaker 
should also be considered for optimum 
performance. 
 
Guidelines for component placement are as follows: 
 

Faucet 

should be placed near the sink where 

drinking / cooking water is normally required.  A 2” 
flat surface is required to mount the faucet if an 
existing hole for a second faucet is not available.  
The thickness of the mounting surface should not 
exceed 1-1/4”. 
 

Feed water connection 

is accomplished with a 

self-piercing feed water saddle valve.  Locate this 
assembly as close to the system as possible.  
Connect to a potable, cold water supply line only. 
 
Note:  Plumbing codes may require the use of air 
gaps.  Please check with your local municipality. 
 

Site reparation 
 

Installing dealers may want to speak with 
customers in advance and ask them to clean under 
the sink to save time.  If a basement installation is 
advisable, check area to determine if extra fittings 
or hosing are required.  Upon arrival, it is a good 
idea to check the condition of all plumbing for 
potential leaks and advise customer so there will be 
no misunderstandings in the event leaks occur. 

 
Unit preparation 
 

Open shipping carton, remove components and 
check that all parts are present. 
 
 

Installation steps 
 

 
All plumbing must be completed in accordance with 
state and local plumbing codes. Some 
municipalities may require installation by a licensed 
plumber.  Check local authority prior to installation.

 

 
1. Faucet 

installation 

 

If the sink has a sprayer it may be disconnected for 
faucet installation.  (Installing dealers should 
discuss this with customers.)  A pipe cap or plug will 
be necessary to seal the sprayer connection. 
 

Содержание Residential Drinking Water System

Страница 1: ...Installation Instructions AdEdge Residential Drinking Water System OPERATION MANUAL AdEdge Technologies Inc 5152 Belle Wood Court Suite A Buford GA 30518...

Страница 2: ...EM LOCATION 2 Faucet 2 Feed water connection 2 Site reparation 2 Description INSTALLATION STEPS 2 1 Faucet installation 2 2 Mounting the faucet 4 3 Feed water valve and tube installation 4 4 Initial t...

Страница 3: ...ble space Do not install unit where temperatures fall below freezing otherwise damage will result Connection to an icemaker should also be considered for optimum performance Guidelines for component p...

Страница 4: ...g spring loaded porcelain cutter making certain a complete ring has been cut through the porcelain enamel to the metal base 6 Cut away the inner porcelain enamel disc down to the base metal Make certa...

Страница 5: ...lve on copper tubing 4 Turn handle clockwise to pierce soft copper tube until valve is firmly seated Valve is closed in this position 5 Turn on water supply to pressure cold water line 6 Snug nut seal...

Страница 6: ...es Initial water may be slightly discolored or contain a few small particles of filter media These particles are harmless and non toxic This is normal during filter conditioning and will subside prior...

Страница 7: ...710S two filter housings faucet feed water saddle valve tubing fittings and a water meter which will count gallons and automatically shut off the system once 1000 gallons has been filtered This specia...

Отзывы: