background image

 

5

 

Tubing should follow contour of the cabinets. 

 

Cut tubing to desired length using square cuts 
and proper cutting devise. 

 

Make no sharp bends. 

 

Keep tubing from the unit to the faucet as short 
as practical for good flow. 

 
Under sink installations following installation 
diagram and the following procedures: 
 
1.  Connect tubing from faucet to meter. 
2.  Connect tubing from supply valve to unit. 
 

Icemaker hookup (optional) 
 

The drinking water device can be connected to any 
standard refrigerator icemaker or icemaker / water 
dispenser.  (Do not connect to a commercial type 
bar icemaker.) 
 
To complete this operation, connect a tee with shut-
off valve into the faucet tubing and route tubing to 
the refrigerator.   (Hooking up to an existing copper 
line is not recommended unless it is new 
installation.)  Shut off icemaker by lifting lever prior 
to turning off the existing tap water supply line to 
the refrigerator.   
 

System start-up 
 

Prior to start-up: 
 
1.  Check all connections be sure they are secure. 
2.  Turn on feed water valve and check for leaks. 

(Turn off and correct leaks if leaks occur.) 

3.  Close faucet and wait five minutes to see if 

leaks result. 

4.  If no leaks are present, turn metering valve 

clockwise and set to 800 if AD2710C cartridge 
is installed.  Otherwise, set to gallons 
recommended for your cartridge. 

5.  Open faucet and run water for approximately 

ten minutes to condition filter cartridges.  Initial 
water may be slightly discolored or contain a 
few small particles of filter media.  These 
particles are harmless and non-toxic.  This is 
normal during filter conditioning, and will 
subside prior to the end of the 10 minute period. 

 
 

Maintenance 
 

Your drinking water system contains cartridges 
which must be replaced periodically for proper 

operation.  (Please see page 2 for cartridge 
information) 
 
Note:  Change-out procedures may be amended, 
depending on source water conditions. 
 
To change filter cartridges follow these procedures: 
 

1.  Close feed water valve by turning it clockwise. 
2.  Open faucet to release pressure. 
3. Loosen and remove filter housings using 

wrench provided and discard cartridges. 

4.  Wash the inside of the housings using mild 

detergent and soft cloth.  Thoroughly rinse all 
soap before reassembly. 

5.  Replace filter cartridges.  
 

John Guest® brand fittings 
 

Model DWS-2S-2710-01 utilizes John Guest® 
brand fittings.  These user-friendly fittings provide 
superior performance and virtually eliminate the 
potential for leaks. Proper use of these 

push-in 

fittings is shown below. Along with these fittings, all 
tubing selected must be of high quality and must be 
cut with a plastic tube cutter or sharp razor with a 
clean, square cut. 
 
 
Should a leak occur at a fitting, the cause is 
generally defective tubing.  To fix a leak, relieve 
pressure, release tubing, cut off at least 1/4" from 
the end (square cut), reattach the tubing and 
confirm the connection is leak free.  Each time a 
new connection is made, it is advisable to cut off 
1/4" from the end of the tubing using these fittings. 

 
 
 

 
 
 
 
 

 
 
 
 
 
 
 

Содержание Residential Drinking Water System

Страница 1: ...Installation Instructions AdEdge Residential Drinking Water System OPERATION MANUAL AdEdge Technologies Inc 5152 Belle Wood Court Suite A Buford GA 30518...

Страница 2: ...EM LOCATION 2 Faucet 2 Feed water connection 2 Site reparation 2 Description INSTALLATION STEPS 2 1 Faucet installation 2 2 Mounting the faucet 4 3 Feed water valve and tube installation 4 4 Initial t...

Страница 3: ...ble space Do not install unit where temperatures fall below freezing otherwise damage will result Connection to an icemaker should also be considered for optimum performance Guidelines for component p...

Страница 4: ...g spring loaded porcelain cutter making certain a complete ring has been cut through the porcelain enamel to the metal base 6 Cut away the inner porcelain enamel disc down to the base metal Make certa...

Страница 5: ...lve on copper tubing 4 Turn handle clockwise to pierce soft copper tube until valve is firmly seated Valve is closed in this position 5 Turn on water supply to pressure cold water line 6 Snug nut seal...

Страница 6: ...es Initial water may be slightly discolored or contain a few small particles of filter media These particles are harmless and non toxic This is normal during filter conditioning and will subside prior...

Страница 7: ...710S two filter housings faucet feed water saddle valve tubing fittings and a water meter which will count gallons and automatically shut off the system once 1000 gallons has been filtered This specia...

Отзывы: