4
ZW60-210531-Rev006-UM-en
- Use the scale at constant ambient temperatures and avoid using in draughts, otherwise the
measurement results could be falsified.
- Place the scale as far as possible from other devices or sources that generate electroma-
gnetic field or other interferences (e.g. strong motors and portable and mobile HF commu-
nication devices) as these can falsify the measurement results.
- Use only approved accessories and peripherals.
- Before cleaning the device, pull the mains adapter/plug out of the socket.
- Never clean the scale with abrasive or aggressive cleaning agents.
- Do not immerse the device in water or other liquids.
- If you have problems with this device, e.g. when setting up, maintaining or using, please
contact the authorised customer service. Do not open or repair the device yourself.
- Please notify the authorised customer service if unexpected operations or events occur.
- If the weighing system is not used for a longer period of time, it should be cleaned and
stored in a protective film. The addition of a drying agent is desirable.
DO NOT use the scale:
- If the mains adapter is damaged;
- If the mains adapter is not working;
- If the battery compartment has an unnatural bulge;
- After long storage in a humid environment.
In such cases, please contact authorised customer support.
4. Set up of the scales
1. Carefully remove the delivery contents from the packaging.
2. If necessary, remove the transport lock before operating the scale. The transport lock
(if any) is located on the underside of the scale.
3. Place the scale on a stable, horizontal surface. Do not place the scale on a shaky or
vibrating table as this will cause distortion of measurement results.
4. Do not place the scale near vibrating machines.
5. To align the scale, adjust the four feet of the scale so that the air bubble is exactly in
the centre of the spirit level.
6. Remove the weighing platform from the separate packaging and insert it carefully into
the holes on the top of the scale.
7. Connect the power adapter to the socket on the underside of the scale. Switch on the
scale. The on/off switch is located on the right-hand side under the housing. When
switching on the scale, the weighing platform must be unloaded. The software version
number appears on the display, followed by the maximum capacity shortly thereafter.
Then the scale runs a test programme and confirms the end of the testing routine with
a sound signal.
If the weighing platform is loaded when switching on the scale, the
scale will not be properly calibrated and ready for use.
With the weighing platform unloaded, switch off the scale and then
switch it on again.
8. The scale is now ready for use.
9. For accurate measurement results, the item to be weighed must be placed in the
middle of the weighing platform. The item to be weighed should not protrude beyond
the weighing platform.
Содержание ZW60-45
Страница 1: ...OPERATING MANUAL Electronic table scales Control scale Model ZW60 45 ZW60 210531 Rev006 UM en ...
Страница 17: ...ZW60 210531 Rev006 UM en 17 ...
Страница 18: ...18 ZW60 210531 Rev006 UM en ...
Страница 19: ...ZW60 210531 Rev006 UM en 19 ...
Страница 20: ...20 ZW60 210531 Rev006 UM en Händler ...