background image

10 

 

 

ZW60-210531-Rev006-UM-en 

6.7.1 

Manual totaliser 

The scale can be set so that the weight valueson the display are added to the values in the 
totaliser by pressing the 

M+

 button. 

The display shows “AC 1” first and then the currently stored total weight for approx. 2 
seconds before returning to the normal weighing mode. 

If a printer or PC is connected via the RS232 interface (optional, not upgradeable), the result 
will be output ac-cordingly. 

Remove the applied weight. 

As soon as the scale returns to zero position, a second weight can be applied. 

Press the 

M+

 button to add the value to the totaliser. 

The display now shows “AC 2” first and then the currently stored total weight for approx. 2 
seconds before re-turning to the normal weighing mode. 

This process can be repeated until all weights have been added. 

A total of 99 operations can be performed or until the rated capacity of the scale has been 
reached. 

When the weighing surface is unloaded and the display shows zero, press the 

MR

 button to 

recall the stored value. Now the scale display shows the number of weights as “AC xx” and 
the total weight before returning to zero. 

The total weight may also be output to a connected printer or PC via the RS232 interface 
(optional, not upgrade-able). 

To clear the totaliser, press the 

MC

 button.. 

 

The M+ sum function is enabled only if the display shows “STABLE”. 

6.7.2 

Automatic totaliser 

The scale can be set so that the weight values on the display are automatically added to the 
values in the totalis-er. For this purpose, parameter P6 “Ato” must be enabled (setting = Au 
on). For more details, see parameter settings. 

When the automatic totaliser is enabled, the display shows 

AUTO

Put a weight on the weighing surface. As soon as the scale is stable, it will automatically add 
the weight to the totaliser. This is confirmed by an audible signal. 

Remove the weight from the weighing surface. 

The display now shows “AC 1” and then the stored total weight before the scale returns to 
the normal weighing mode. 

As soon as the scale returns to zero position, a second weight can be applied, and the 
weight will automatically be added to the totaliser. 

A total of 99 operations can be performed or until the rated capacity of the scale has been 
reached. 

The total weight can be recalled as described above. 

When the weighing surface is unloaded and the display shows zero, press the 

MR

 button to 

recall the stored value. Now the scale display shows the number of weights as “AC xx” and 
the total weight before returning to zero. 

The total weight may also be output to a connected printer or PC via the RS232 interface 
(optional, not upgrade-able). 

To clear the totaliser, press the 

MC

 button. 

Содержание ZW60-45

Страница 1: ...OPERATING MANUAL Electronic table scales Control scale Model ZW60 45 ZW60 210531 Rev006 UM en ...

Страница 2: ...roing the scale 7 6 2 Taring 7 6 3 Determining the weight 8 6 4 Weighing in percent 8 6 5 Piece counting 8 6 5 1 Method 1 Unknown reference weight 8 6 5 2 Method 2 Known reference weight 8 6 6 Presetting the maximum and minimum values for audible alarm 9 6 7 Totaliser 9 6 7 1 Manual totaliser 10 6 7 2 Automatic totaliser 10 7 Parameters 11 8 Care and maintenance 13 8 1 Cleaning 13 8 2 Error indica...

Страница 3: ...between such units as kg g lbs and oz Power is supplied via a 230 V mains connection or a 6 V 4 Ah rechargeable battery 2 Delivery contents Included in the delivery are Scales Rechargeable battery integrated into the scale Weighing platform Power adapter User manual incl declaration of conformity 3 Safety instructions It is essential that you read understand and follow all instructions in these in...

Страница 4: ...es 1 Carefully remove the delivery contents from the packaging 2 If necessary remove the transport lock before operating the scale The transport lock if any is located on the underside of the scale 3 Place the scale on a stable horizontal surface Do not place the scale on a shaky or vibrating table as this will cause distortion of measurement results 4 Do not place the scale near vibrating machine...

Страница 5: ...on Skips the active digit one place to the right when entering values of adjustable parameters or other functions MODE Mode button Changes the units in weighing mode Changes display between unit weight counted quantity and total weight in counting mode Displays weight in percent mode The scale automatically returns to percent mode in three seconds Secondary function Skips the active digit one plac...

Страница 6: ...weight value in weighing mode or the minimum quantity in counting mode If the applied weight or the applied quantity is smaller than the minimum value you will hear an audible signal To enter the value press and hold down this button for 3 seconds 0 9 Manual entry of values Numeric buttons from 0 to 9 are used to manually enter values such as unit weight or reference quantity C Clear manually ente...

Страница 7: ...rgeable battery or if the rechargeable battery is used for several years without replacement it is possible that the rechargeable battery will no longer be fully charged If the rechargeable battery life becomes unacceptable contact your customer service representative or the manufacturer 6 Operation 6 1 Zeroing the scale When the gross weight is within 2 of zero a new zero point is set as when the...

Страница 8: ...return to the weighing mode 6 5 Piece counting 6 5 1 Method 1 Unknown reference weight First possibly tare the empty container as described above and leave it on the weighing surface Press the SMPL button to start counting pieces Place a certain number of items to be weighed on the weighing surface You must know the exact number Enter this number using the numeric keypad Press the SMPL button agai...

Страница 9: ...play shows OK The minimum value is set and the maximum value is zero The display shows OK as long as the weight is lower than the set minimum value When the applied weight exceeds the minimum value the display shows HIGH The minimum value is zero and the maximum value is set The display shows LOW as long as the applied weight is lower than the set maximum value When the applied weight exceeds the ...

Страница 10: ...not upgrade able To clear the totaliser press the MC button The M sum function is enabled only if the display shows STABLE 6 7 2 Automatic totaliser The scale can be set so that the weight values on the display are automatically added to the values in the totalis er For this purpose parameter P6 Ato must be enabled setting Au on For more details see parameter settings When the automatic totaliser ...

Страница 11: ...E button moves to the next lower setting Press the ZERO button again to save your entries Press the G N button to exit the menu without saving Please note that some functions are only reserved for use by authorised technicians according to the overview below PARA METER SUB PARA METER DISPLAY SETTING P0 CAL External calibration Reserved for use by authorised technicians only P1 LCA Linearity calibr...

Страница 12: ...ptions Auto on off Auto Backlight is enabled when the weighing surface is loaded on Backlight is permanently enabled of Backlight is permanently disabled P12 bP BEEP Audible signal setting for checkweighing 0 Audible signal is disabled 1 Audible signal between two values is enabled 2 Audible signal beyond two values is enabled P13 ti Time Year date and time setting Navigate within the digits with ...

Страница 13: ...tch on zero exceeds the permissible value typically 4 of the maximum weighing range when the scale is switched on or when the ZERO button is pressed The weighing platform has already been loaded when the scale has been switched on Weighing platform overload when the scale is set to zero Improper calibration of the scale Damaged load cell Damaged electronics Err 5 Keypad fault Improper use of the s...

Страница 14: ...idence is provided that it has failed within 1 year from the date of sale proof of purchase is required due to lack of workmanship or defective material All moving parts such as batteries cables etc are excluded The use of accessories other than those approved by ADE especially batteries will void the warranty This warranty does not cover external normal wear and tear or damage caused by accident ...

Страница 15: ... adapter Calibration With external weight Display 6 digit LCD digital displays 52 mm digit height Housing ABS plastic housing stainless steel weighing platform Weighing platform 365 x 235 mm Housing dimensions WxDxH 365 x 365 x 135 mm Net weight 5 1 kg Applications Multi purpose scale with simple piece counting function Functions Weighing piece counting totaliser freely programmable minimum and ma...

Страница 16: ...rer This product has been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in the currently valid versions This declaration will lose its validity if any modification is made to the scale without our consent Hamburg May 2021 ADE Germ...

Страница 17: ...ZW60 210531 Rev006 UM en 17 ...

Страница 18: ...18 ZW60 210531 Rev006 UM en ...

Страница 19: ...ZW60 210531 Rev006 UM en 19 ...

Страница 20: ...20 ZW60 210531 Rev006 UM en Händler ...

Отзывы: