Restore the preset PRESET TARA value: 

Press the PRESET TARE key (10). "Pt  x" appears on the display. Enter a number from 0-9 (memory location 
for the tare value). If no number is entered within five seconds, the unit will turn back to weighing mode. 
After entering the number, the ADE-MAK accesses the preset tare value, shows it for five seconds on the dis-
play  and  then  changes  to  net  mode.  The  accessed  tare  value  is  accepted  at  the  same  time.  Enter  the  tare 
button again to leave this mode. 

Displaying the gross weight, net weight and tare value: 

Press  the  "0"  key  to  change  between  displays  for  tare,  gross  weight  (NET  status  indicator  (5)  off)  and  net 
weight (NET status indicator (5) on). If a tare value is saved, the net weight shown corresponds to the gross 
weight minus the tare value. If there is no tare value saved, the display remains in gross mode.  
The tare value flashes briefly, then after a second the display changes to gross mode. 
 

Hold function 

Use the HOLD key to hold the display if there are weight fluctuations which e.g. are caused by patient move-
ments  on  the  scales.  You  could  also  use  this  function  if  you  like  to  hold  the  results  at  the  display  after  the 
weight/load has been removed from the scale. 
 
To do this, the scales must be at standstill, e.g. the standstill status indicator 

 (14) is on (depending on the 

setting it is not always necessary for the scales to be at standstill). The 

Hold

 status indicator (15) is on. 

 

Deactivate the HOLD function by pressing the key again. 

Determining the Body Mass Index (BMI) 

The BMI figure is a index which displays the ratio between height and weight. 

BMI= 

body weight 

(height)² 

To determine this value you need the height of the person. Best way to get the height is of course to use an 
ADE height measuring rod; model MZ10023. 
Start the scale and weigh the person. Then press the BMI key (11) to start BMI mode. The last value entered 
appears  on  the  display.  Use  the  numerical  key  pad  to  enter  a  new  value  for  the  height  (in  cm)  or  retain  the 
value which is already displayed.  
Confirm the value entered with the ENTER key or delete same by using the CLEAR key. After the entry has 
been confirmed by the ENTER key, the BMI value will be calculated using the weight on the scales. The dis-
play  changes  between  weight  value  and  BMI  value  "b    xx.x"  (every  two  seconds)  for  a  period  of  3  minutes. 
Press the BMI key (11) to cancel befoe this time has expired. 

Evaluating Body Mass Index 

 

 

 

 

 

 

 

BMI evaluation according to WHO 

BMI   

<  16 

Severely underweight 

  16 

17 

Moderately underweight 

  17 

18.5  Slightly underweight 

BMI  18.5 

25 

Normal weight 

BMI  25 

30 

Overweight 

  30 

35 

Obese Class I 

  35 

40 

Obese Class II 

   

>  40 

Obese Class III 

 

Содержание M301020 Series

Страница 1: ...M301020 01 210322 Rev005 UM e Operating Manual Class III approved Scales Electronic Platform and Handrail Scales Series M301020...

Страница 2: ...al devices 6 Housing and connections 7 Modes 7 Settings 7 Setting date and time 8 Operation 8 Weighing 8 Resetting the scales back to zero 8 Tare function 8 Hold function 9 Determining the Body Mass I...

Страница 3: ...y Attachment of the indicator The ADE scales are delivered in a largely assembled state Only model M301020 requires the indicator to be connected to the weighing platform Connect the indicator to the...

Страница 4: ...d require a recharging period If the bat tery performance drops considerably then it is time to replace the battery New batteries are supplied only partially charged Some batteries only achieve their...

Страница 5: ...button Short push on the button to recover the stored tare value Long push on the button to enter and save the tare value 11 BMI Button Enter to proceed with BMI mode and to enter as next step the he...

Страница 6: ...s not pose any potential trip hazard Only use approved accessories and peripheral equipment Only operate the unit under permitted ambient conditions Remove the mains plug before cleaning the unit Do n...

Страница 7: ...s for print commands are being set in this mode To start setting mode hold the GROSS NET key pressed until TIME appears on the display Configuration mode set up mode The values for different parameter...

Страница 8: ...the scale are being compensated The zero key restarts the scale The status indicator 6 appears when the scale is being resetted Tare function The TARE key 9 is used when the patient is being weighed...

Страница 9: ...scale To do this the scales must be at standstill e g the standstill status indicator 14 is on depending on the setting it is not always necessary for the scales to be at standstill The Hold status i...

Страница 10: ...city of the scales Overflow indicator negative Negative weight indicated weight too low to be displayed 99999 Overflow indicator positive Positive weight indicated weight too high to be displayed 9999...

Страница 11: ...tc are excluded This warranty does not cover any normal external appearance of use and wear or any damage occurring as a result of an accident or misuse Any warranty or damage compensation claims pres...

Страница 12: ...ort Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operat...

Страница 13: ...ufacturer This product has been manufactured in accordance with the harmonised European standards They con form to the regulations of the EC directives listed below NAWI Directive 2014 31 EC Medical D...

Страница 14: ...14 M301020 01 210322 Rev005 UM e...

Страница 15: ...M301020 01 210322 Rev005 UM e 15...

Страница 16: ...16 M301020 01 210322 Rev005 UM e Dealer...

Отзывы: