ADE M301020 Series Скачать руководство пользователя страница 12

12 

 

M301020-01-210322-Rev005-UM-e 

 

Technical specifications 

Power supply 

Mains Adapter: 

Mains voltage 

115 or 230VAC 

Frequency 

50 or 60HZ 

Power Consumption 

11W in-charger, 2W off-charger 

Main power circuit 

Input Voltage  

5.0VDC 

Max. Current (in-charger) 

1000mA 

 
Battery Requirement: 

Rechargeable Lithium Ion Cylindrical (18650x2) Cell 3.7V 4000mAH 

Battery Operation: 

Charger  

7~10 Hours 

Saving (350ohm, Backlight-ON 30Sec, 
Shutdown 5Min) 

200Hours 

 

Serial Communications 

EDP Port 

Full duplex RS-232 

 

38400,19200,9600, 4800, 2400, 1200 bps 

Printer Port 

Output-only RS-232 or active 20 mA current loop,  

 

9600, 4800, 2400, 1200 bps 

Both Ports 

7 or 8 data bits; even, odd, or no parity 

 

Operator Interface 

Display 

6-digit LCD display. 7-segment, 0.815 in (21.2 mm) digits 

LCD annunciator 

net, center of zero, standstill, kg/lb/g/oz/ units,  

 

Battery, Set points, Hold, HI/OK/LO 

Keyboard 

24-key flat membrane panel 

Environmental 

Operating Temperature 

–10 to +40°C (legal); 

Storage Temperature 

–25 to +70°C 

Humidity 

0–95% relative humidity 

Altitude 

2000 m (6500 ft) maximum 

Housing

 

Dimensions 

18.6 cm x 9.5 cm x 10 cm 

Weight 

0.4 kg (without battery) 

Material 

ABS plastic, white 

Содержание M301020 Series

Страница 1: ...M301020 01 210322 Rev005 UM e Operating Manual Class III approved Scales Electronic Platform and Handrail Scales Series M301020...

Страница 2: ...al devices 6 Housing and connections 7 Modes 7 Settings 7 Setting date and time 8 Operation 8 Weighing 8 Resetting the scales back to zero 8 Tare function 8 Hold function 9 Determining the Body Mass I...

Страница 3: ...y Attachment of the indicator The ADE scales are delivered in a largely assembled state Only model M301020 requires the indicator to be connected to the weighing platform Connect the indicator to the...

Страница 4: ...d require a recharging period If the bat tery performance drops considerably then it is time to replace the battery New batteries are supplied only partially charged Some batteries only achieve their...

Страница 5: ...button Short push on the button to recover the stored tare value Long push on the button to enter and save the tare value 11 BMI Button Enter to proceed with BMI mode and to enter as next step the he...

Страница 6: ...s not pose any potential trip hazard Only use approved accessories and peripheral equipment Only operate the unit under permitted ambient conditions Remove the mains plug before cleaning the unit Do n...

Страница 7: ...s for print commands are being set in this mode To start setting mode hold the GROSS NET key pressed until TIME appears on the display Configuration mode set up mode The values for different parameter...

Страница 8: ...the scale are being compensated The zero key restarts the scale The status indicator 6 appears when the scale is being resetted Tare function The TARE key 9 is used when the patient is being weighed...

Страница 9: ...scale To do this the scales must be at standstill e g the standstill status indicator 14 is on depending on the setting it is not always necessary for the scales to be at standstill The Hold status i...

Страница 10: ...city of the scales Overflow indicator negative Negative weight indicated weight too low to be displayed 99999 Overflow indicator positive Positive weight indicated weight too high to be displayed 9999...

Страница 11: ...tc are excluded This warranty does not cover any normal external appearance of use and wear or any damage occurring as a result of an accident or misuse Any warranty or damage compensation claims pres...

Страница 12: ...ort Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operat...

Страница 13: ...ufacturer This product has been manufactured in accordance with the harmonised European standards They con form to the regulations of the EC directives listed below NAWI Directive 2014 31 EC Medical D...

Страница 14: ...14 M301020 01 210322 Rev005 UM e...

Страница 15: ...M301020 01 210322 Rev005 UM e 15...

Страница 16: ...16 M301020 01 210322 Rev005 UM e Dealer...

Отзывы: