No.  Name 

Description 

16 

“Ib” 

If displayed is the weight is displayed in pounds 

17 

“oz” 

If displayed is the weight is displayed in ounces 

18 

“kg” 

If displayed is the weight is displayed in kilograms 

 

“g” 

If displayed is the weight is displayed in grams 

 

 

 

Safety 

Safety instructions 

The ADE-display unit (MAK) corresponds to the latest state of the art technology and complies with standard 
regulations  and  directives.  Kindly  follow  the  safety  instructions  in  this  operating  manual,  the  country-specific 
installation  standards  as  well  as  the  applicable  safety  conditions  and  accident  prevention  regulations  in  all 
aspects. Portable and mobile HF-communication systems may influence electronic medical devices. 

Electronic medical devices are restricted to special safety regulations in respect of their electromagnetic com-
patibility. For positioning and operation follow the instructions of this Operating Manual. 

– 

Before  commissioning,  ascertain  whether  the  mains  voltage  and  power  type  stated  on  the  type  plate 
match the mains voltage and power type at the place of use. 

– 

Make sure that the mains cable does not pose any potential trip hazard. 

– 

Only use approved accessories and peripheral equipment. 

– 

Only operate the unit under permitted ambient conditions. 

– 

Remove the mains plug before cleaning the unit. 

– 

Do not operate the unit in hazardous or unstable conditions. 

– 

Do not submerge the unit in water or other liquids. 

– 

All actions/operations described in this operating manual may only be carried out by trained and by ADE 
authorised professional personnel. 

– 

Using  accessories  that  do  not  meet  the  safety  requirements  of  this  unit  can  lead  to  a  reduction  in  the 
safety level of the entire system. 

– 

Set up the unit as far away as possible from equipment that generates electromagnetic or other interfer-
ence. 

– 

Only ADE power adapters are allowed to use to avoid any risk of fire and electric shock. 

– 

Clean with a dry cloth; do not use any sharp cleaning materials. 

Hazard-free operation is no longer guaranteed 

If the power unit exhibits visible damage. 

If the power unit is no longer working. 

After longer periods of storage in damp rooms. 

Inform your service partner in such cases for your own safety. 

Connecting additional devices 

Connection  of  printer,  PC  or  remote-display  will  be  done  with  the  RS-232  interface.  For  connection  of  addi-
tional devices kindly ask your local representative or authorized ADE dealer for further instructions. 

Содержание M301020 Series

Страница 1: ...M301020 01 210322 Rev005 UM e Operating Manual Class III approved Scales Electronic Platform and Handrail Scales Series M301020...

Страница 2: ...al devices 6 Housing and connections 7 Modes 7 Settings 7 Setting date and time 8 Operation 8 Weighing 8 Resetting the scales back to zero 8 Tare function 8 Hold function 9 Determining the Body Mass I...

Страница 3: ...y Attachment of the indicator The ADE scales are delivered in a largely assembled state Only model M301020 requires the indicator to be connected to the weighing platform Connect the indicator to the...

Страница 4: ...d require a recharging period If the bat tery performance drops considerably then it is time to replace the battery New batteries are supplied only partially charged Some batteries only achieve their...

Страница 5: ...button Short push on the button to recover the stored tare value Long push on the button to enter and save the tare value 11 BMI Button Enter to proceed with BMI mode and to enter as next step the he...

Страница 6: ...s not pose any potential trip hazard Only use approved accessories and peripheral equipment Only operate the unit under permitted ambient conditions Remove the mains plug before cleaning the unit Do n...

Страница 7: ...s for print commands are being set in this mode To start setting mode hold the GROSS NET key pressed until TIME appears on the display Configuration mode set up mode The values for different parameter...

Страница 8: ...the scale are being compensated The zero key restarts the scale The status indicator 6 appears when the scale is being resetted Tare function The TARE key 9 is used when the patient is being weighed...

Страница 9: ...scale To do this the scales must be at standstill e g the standstill status indicator 14 is on depending on the setting it is not always necessary for the scales to be at standstill The Hold status i...

Страница 10: ...city of the scales Overflow indicator negative Negative weight indicated weight too low to be displayed 99999 Overflow indicator positive Positive weight indicated weight too high to be displayed 9999...

Страница 11: ...tc are excluded This warranty does not cover any normal external appearance of use and wear or any damage occurring as a result of an accident or misuse Any warranty or damage compensation claims pres...

Страница 12: ...ort Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operat...

Страница 13: ...ufacturer This product has been manufactured in accordance with the harmonised European standards They con form to the regulations of the EC directives listed below NAWI Directive 2014 31 EC Medical D...

Страница 14: ...14 M301020 01 210322 Rev005 UM e...

Страница 15: ...M301020 01 210322 Rev005 UM e 15...

Страница 16: ...16 M301020 01 210322 Rev005 UM e Dealer...

Отзывы: