background image

 

INNEHOLD:

 

Airborne DC kretskort

 

Mål (BxHxD): 58x105x25 mm

 

Ladekort

 

Plastkabinett, sabotasjesikret.

 

Mål (BxHxD): 170x160x60 mm

 

1stk. NiMH 2200  mAh batteri

 

Ekstern 15 VDC strømadapter

 

Integrert SIM-kort (e-SIM) med 

 

tilhørende AddSecure  abonnement

 

Hurtigmanual

 

Informasjon og support

 

Intern antenne

 

Monteringsskruer

 

Alarmetikett

AIRBORNE 

DC MEDIUM

Hurtigmanual/
Snabbguide

 

INNEHÅLL:

 

Airborne DC kretskort

 

Mått

(BxHxD):

 58x105x25  

mm

 

Laddkort

 

Plastkapsling, sabotagesäker.

 

Mått (BxHxD): 170x160x60  

mm

 

1st. NiMH 2200  mAh batteri

 

Extern 15 VDC strömadapter

 

Integrerat SIM-kort (e-SIM) med

 

tillhörande AddSecureabonnemang

 

Snabbguide

 

Information och support

 

Intern antenn

 

Monteringsskruvar

 

Dekaler

GODKJENNELSER/GODKÄNNANDE

2544-CPr -P20727-F03-16

EN54-21:2006 Type 1
EN50136-1:2012 ATS: SP4
EN50136-2:2013
EN50131-1:2006/A1:2009 

g

R2 ECII

UMTS: ATS5

EN50130-4:2011
EN50130-5:2011
SBF110:7
SSF114:2 Larmklass 2

SaFetY

Care should be taken when connecting telecommunications equipment to ensure only like inter-
faces are connected to avoid safety hazards .

SELV:  SELV (Safety Extra-Low Voltage) is defined as a secondary circuit which is so designed  
 

 

and protected that under normal and single fault conditions the voltage between any  

 

 

two accessible parts does not exceed a safe value (42 .4V peak or 60V dc maximum)

The interfaces on the IRIS-4 160 have the following safety classifications:

 

•  Dial capture interface: SELV suitable for connection to the TNV interface of single line 

 

 

telecommunications equipment such as telephones, alarm panels, etc .

 

•  Power Interface: SELV for connection to a DC supply

 

•  Inputs: SELV for connection to alarm output pin.

ConFoRManCe

European Directives

The IRIS-4 160 complies with the following European Directives:

 

•  2014/53/EU (Radio Equipment Directive)

 

•  2013/35/EU (Electromagnetic Fields)

 

•  2004/108/EC (CE directive) 

 

•  2002/96/EC (WEEE) 

 

•  2011/65/EC (ROHS)

EN50131, EN50136 (VdS Certified)
The dialler is compliant with the requirements of European Standards:
EN 50131-1: 2006+A2:2017 & EN 50131-10:2014
EN 50136-1: 2012 & EN 50136-2: 2013
Security Grade 2 
ATS-SP3 over Ethernet or Wi-Fi, ATS-SP3 over 4G/3G/2G, and ATS-DP2
Environmental Class II 
 

Содержание IRIS-4 160

Страница 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 160 Quick Installation and Maintenance Guide...

Страница 2: ...mission System ATS configuration up to SP3 for single path or ATS configuration DP2 for dual path The IRIS 4 160 is based on the successful IRIS Touch NG range of AoIP diallers with the same hardware...

Страница 3: ...en the following information will not be required as it will be assigned by the network IP address Gateway address Subnet mask address Wi Fi Connection Details The customer s Wi Fi network details are...

Страница 4: ...tened or other activities such as alarm alerting by the panel at regular intervals If batteries are required DO NOT FIT until indicated in Section 6 9 Configuration Use Batteries approved to IEC61951...

Страница 5: ...s the equivalent restore signal Via Sense Resistors It is also possible to link the contacts to the IRIS 4 160 dialler via sense resistors so that an open or short circuit tamper on the loop is detect...

Страница 6: ...local Configuration viaWeb Browser usingWi Fi Connection Can be configured using the Wi Fi connection using a standard Web browser from any smartphone tablet or laptop device and supports the followin...

Страница 7: ...and follow the on screen prompts Note 1 If installing the IRIS 4 160 without batteries then please untick the Use battery backup option Note 2 During the Installation Wizard the Wi Fi status screen a...

Страница 8: ...heck battery status and replace if below required level Reflash IRIS 4 160 software to latest version Test the configured communication paths Ethernet Wi Fi 4G 3G 2G Perform full test of alarms from t...

Страница 9: ...atteries fitted for backup purpose replaced them every two years 7 4 Check SoftwareVersion Reflash Go to the settings menu and then select Latest software this will then check with the AddSecure Refla...

Страница 10: ...up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 reference SIA DC 03 1990 01 R2003 10 Contact ID reference SIA DC 05 1999 09 Fast format Scancom for dial capture and serial connection...

Страница 11: ...s are connected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltag...