About this manual

 

This manual provides a guide to the installation and maintenance of the 

VS5010 and Edge VS5051 terminals.  

2

 

Target group

 

This manual is intended to provide assistance to engineers installing and 

maintaining the Edge VS5010 or Edge VS5051 terminals at customer sites. 

3

 

Presentation of the terminals

 

Edge terminals, based on the successful range of AoIP Alarm over IP (AoIP) 

terminals from AddSecure, offer a new concept in AoIP, providing cost 

effective VoIP/AoIP for alarm systems. Both the Edge VS5010 and the Edge 

VS5051 are based on the Edge VS5000 motherboard. This motherboard is a 

fully equipped circuit board designed to fulfill the task of a Grade 4 Secured 

Premises Transmitter (SPT) and meets all relevant standards for EN 

compliance in intercom and elevator systems. 
The two products based on the VS5000 motherboard are as follows: 

 

Polling and alarm transmission to the alarm receiving centre (ARC) are 

performed using 2G/3G/4G, Ethernet or Wi-Fi communications via the 

AddSecure Connect platform. 

3.1

 

AddSecure Connect

 

AddSecure Connect is a cloud-based platform that uses a secure private 

LINK network via the on-board eSIM and does not require the installer to 

add a SIM card. It provides secure and controlled alarm transmission for 

fire, intruder, elevator, technical and other alarms. The platform simplifies 

setting up terminals and complying with regulations for the installer, the 

customer and alarm receiving centres.  
Edge terminals are intelligently provisioned through AddSecure Connect. 
AddSecure Connect is perfect for every situation where monitored 

communication between a site and the ARC of choice is required, as well as 

when there is a need for controlled remote access to an external device. 

Add Secure Connect has many features, amongst other, the following: 

  Easy to switch ARC’s when situation, alarm mix, or environment 

changes. 

  Remote access for installers (analysis and setup) to save cost and time. 

  Different alarms routed to separate ARC’s for flexible requirements 

management. 

  One alarm routed to multiple ARCs 

Variant

 

Application

 

VS5010 

Is supplied without an enclosure and is intended to be installed in 

existing enclosures of intercom and elevator applications. 

VS5051 

Is supplied in a metal enclosure with 20Hr battery backup for use 

in elevator applications. 

Содержание Edge VS5010

Страница 1: ...PDK 13010 v 6 0 Edge VS5010 and VS5051 User manual Edge VS5010 and VS5051 User Manual...

Страница 2: ...ackup batteries for VS5051 7 7 6 Connecting voice panels and alarm transmitters 7 7 7 Connecting the terminal 7 7 7 1 Power Outputs 7 7 8 Powering up the terminal 8 8 Configuring the terminal 8 8 1 Ch...

Страница 3: ...1 AddSecure Connect AddSecure Connect is a cloud based platform that uses a secure private LINK network via the on board eSIM and does not require the installer to add a SIM card It provides secure a...

Страница 4: ...u can analyse and setup an installation remotely over AddSecure Connect You can read more about AddSecure Connect on www addsecure com 4 Before you start Ensure that a subscription to AddSecure Connec...

Страница 5: ...Light BT Not in use DC power in PNL Panel LED Expansion port PWR Power LED TTL serial port CEL Cellular LED Pin inputs 4 ETH Ethernet LED RS232 port SYS System LED Case Tamper input Cellular diversit...

Страница 6: ...erminal in the enclosure using the fixing kits supplied 2 Connect cables from the alarm panels voice panels and alarm transmitters to the terminal PCBA to the appropriate connections see section 7 6 C...

Страница 7: ...figuration Note Only use battery packs provided by AddSecure 7 6 Connecting voice panels and alarm transmitters All voice panels or alarm panels sited in elevators use the two wire Dial Capture port 2...

Страница 8: ...contact AddSecure 8 Configuring the terminal The terminal does not need to be configured All the configuration and activation is done by AddSecure directly to the unit 8 1 Checking signal strength A g...

Страница 9: ...Local connection Internet accessible Ethernet OK Polling OK data activity System No power System fault System OK 9 Configuration of the voice panels For details about the configuration of specific vo...

Страница 10: ...s required by EU directive 2014 33 11 2 Maintaining data AddSecure keep the information about the location of the plant phone numbers and related information updated based on input from the owner or s...

Страница 11: ...Connection MMCX socket for antenna on PCBA On VS5051 additional SMA socket on the outside of the enclosure Fault detection Loss of registration with network IP TCP ports outbound 53165 Alarms and Poll...

Страница 12: ...tronic protection 2 2A polyfuse Number of switchable outputs 3 Voltage at which fault is reported 10V Voltage at which fault is restored 11V Power storage device Type 7 2V NiMH rechargeable batteries...

Страница 13: ...output pin 14 Conformance The terminal complies with the following European Directives and standards 2014 53 EU Radio Equipment Directive 2002 96 EC WEEE 2011 65 EC ROHS No 1907 2006 REACH EN81 28 EN8...

Страница 14: ...ht No part of this document may be reproduced or used except as authorized by contract or other written permission from AddSecure The copyright and foregoing restriction on reproduction and use extend...

Отзывы: