Page 36 of 80
Not Included
ZS Room
Sensor
Off On
Auto
Universal Input
Mode Select
Aux Power Out
Power
Off
On
Port 1
Rnet
Gnd
RNET+
RNET-
+12V
UO-8
UO-7
UO-6
UO-5
Gnd 8
UO-4
+ 7
Gnd 6
UO-3
+ 5
Gnd 4
UO-2
+ 3
Gnd 2
UO-1
+ 1
Gnd 8
+ 7
Gnd 6
+ 5
Gnd 4
+ 3
Gnd 2
+ 1
UI-8
UI-7
UI-6
UI-5
8 Gnd
UI-4
7 +
6 Gnd
UI-3
5 +
4 Gnd
UI-2
3 +
2 Gnd
UI-1
1 +
UI-12
UI-11
UI-10
UI-9
Rnet Local
Access
Gnd
Rnet+
Rnet-
+12V
Sense
8 Gnd
7 +
6 Gnd
5 +
4 Gnd
3 +
2 Gnd
1 +
8 Gnd
7 +
6 Gnd
5 +
4 Gnd
3 +
2 Gnd
1 +
Gnd
24VAC
0
5
0
5
1
2
3
4
5
6
7
8
10's
1's
Module
Address
NET +
NET -
Shield
Port 1 BT485
Port 2a BT485
485
Port 1
ARC-
156
2 Wire
EIA-
485
4 Wire
EIA-
232
Port 2a
XNET +
XNET -
Gnd
Port 2a
NET +
NET -
n/c
n/c
Signal Ground
Tx +
Tx -
Rx +
Rx -
Tx
Rx
DTR
DCD
2 wire 4 wire EIA-232
mA
Thermistor/
Dry Contact/
RTD
Volts
Off
2
1
Assigned
Default
On
Off
BAS Port
IP Addr
Enhanced
Access Port 2a
BA
Cn
et
BAS Port Settings
BAUD
4
5
Protocols
6
7
8
9600
Off Off
MSTP (m)
Off Off Off
19.2K
Off On
MSTP (s)
On Off Off
38.4K
On Off
PTP
Off On Off
76.8K
On On
N2
On On Off
Modbus
Off Off On
Lon SLTA
On Off On
Lon Option
Off On On
Fuse
24VDC
200mA maximum
100
LAN LINK
10/100 BaseT
Ethernet Port E1
Xnet
Expansion
See BAS Table Below
+ 3V
Gnd
External
Battery
Ext. Batt.
Int. Batt.
0-10Vdc
0-20 mA
Relay
Pot
UO-1
UO-2
UO-3
UO-4
UO-5
UO-6
UO-7
UO-8
Set Pot Full CW
Port 2b
Format
I/O PRO 812u
CONTROLLER
SEE TB4 ON UNIT
WIRING DIAGRAM
R
TB4
BL
FACTORY WIRING
FIELD WIRING
TERMINAL BOARD
SYMBOL LEGEND
USE 18 AWG WIRE MINIMUM. TO MINIMIZE
INTERFERENCE PROBLEMS:
USE SHIELDED WIRE ON ALL ANALOG INPUTS
AND OUPUTS. DO NOT RUN 0-10 VOLT DC
SIGNAL WIRING IN THE SAME CONDUIT AS
LINE VOLTAGE WIRING OR WITH WIRING
THAT SWITCHES HIGHLY INDUCTIVE LOADS
SUCH AS CONTACTOR AND RELAY COILS.
GROUND ONE END OF THE DRAIN (SHIELD)
WIRE.
WHEN 0-10 VOLT DC SIGNAL WIRING MUST
CROSS CLOSE TO CABLE OR NONMETALLIC
CONDUIT CONTAINING LINE VOLTAGE
WIRING OR WIRING THAT SWITCHES HIGHLY
INDUCTIVE LOADS, IT MUST CROSS
PERPENDICULAR (90 DEGREES) TO IT.
KEEP THE 0-10 VOLT DC SIGNAL WIRING AS
SHORT AS POSSIBLE.
LON
1
2
Port 2b
EC
HE
LO
N
LonWorks Card (optional)
FOR FIELD: BAS OR EMS
CONNECTION
3V Litium Battery
CR-123A
-
+
Error Codes:
Chase = OK
0 = Download Required
1 = Control Program Error
2 = RAM full
3 = Comm set-up error
4 = System error
8 = Formatting
Blinking Dot = ‘Run’
DO NOT APPLY 24V AC
TO UNIVERSAL OUTPUTS
External 24VDC relay coil only
24V AC
R
TB-A
GND
GND
24VDC
USE SHIELDED WIRE FOR ALL
ANOLOG INPUTS
WIRE ALL SHIELD WIRES TO CLOSEST TB-A or TB-D
“GND” TERMINAL AT THE CONTROL PANEL
4
24VDC
4
4
R
Heat
Modulating
BK
BK
R
R
BK
BK
R
-A6
+A6
TB1
4
2
tem
p
se
nso
r
V
ou
t
co
m
V i
n
pw
r
OA-T/RH
BK
G
DxLAT1
R
BK
DxLAT1: INSTALL AFTER DX COIL
#1 UPSTREAM OF REHEAT COIL
SA-T/RH
Field install
and wire
1
tem
p
se
nso
r
V
ou
t
co
m
V i
n
pw
r
4
Note: THE SUPPLY/DISCHARGE AIR TEMPERATURE/RELITIVE HUMIDITY
(SA-T/RH) IS FACTORY SUPPLIED FOR FIELD INSTALLATION IN SUPPLY AIR
DUCT. SENSOR MUST BE INSTALLED DOWNSTREAM OF HEATER (IF USED)
WHERE IT CANNOT “SEE” ANY HEATING ELEMENTS AND WHERE
SUFFICIENT MIXING OF DISCHARGE AIR OCCURS. USE 18 AWG SHIELDED
WIRE. DO NOT RUN SENSOR WIRING IN THE SAME CONDUIT AS LINE
VOLTAGE WIRING OR WITH WIRING THAT SWITCHES HIGHLY INDUCTIVE
LOADS SUCH AS CONTACTOR AND RELAY COILS.
1
Install OA-T/RH at the
condensing unit, sensing the
ambient temp/humidity.
2
W
4
SENSORS
DESCRIPTION
CFI
Clogged Filter Indicator
DPT-260
Differential Pressure Transmitter
SAT
Supply Air Temperature Sensor
OA-T/RH
Outdoor Air Temp/Relative Humidity Sensor
SA-RH
Supply Air Relative Humidity
ZS
Zone Temperature Sensor - Standard
CC1-CS, CC2-CS Compressor #1 & #2 Current Sensor
DxLAT
Dx Leaving Air Temperature Sensor
WM-CS
Wheel Motor Current Sensor
SF-APS, EF-APS Supply Fan / Exhaust Fan Air Press. Switch
WFR
Water Flow Relay
LP1, LP2
Low Pressure Switch, Ckt. #1 & #2
SD
Smoke Detector
K3
K4
5
9
Unloader Relay #1
R
PR
Unloader #1
U1
R
TB1
GY
PR
14
13
WARNING!!!
DO NOT leave dip
switch #1 “ON”. This
will result in loss of
BACview and network
communications.
HGRH
(MRC)
-A4
+A4
TB1
G
nd
RN
ET
+
RN
ET
-
+12
V
G
nd
Rn
et
+
Rn
et
-
+12
V
Se
ns
e
Black
Red
G
W
Green
EQUIPMENT
TOUCH
G
nd
Rn
et+
Rn
et-
+2
4V
AC
Red
Black
White
FIELD INSTALL
4
K3
K4
-12V
Rnet
+
Rnet
-
+12V
TB4
TB5
To Wall Mount the
Equipment Touch remove
the factory installed cable
and wire +24VAC to TB4 “K3”
and wire Gnd to TB4 “K4”. If
there is a ZS sensor installed
wire Rnet+ and Rnet- to the
ZS sensor Rnet+ and Rnet –
terminals, otherwise wire to
TB5 Rnet+ and Rnet-
BK
G
W
R
4
BK
R
Equipment Touch
Connector
(Blue)
White
Green
FOR FIELD:
BACNET
CONNECTION
Figure 12: Example Electrical Wiring Diagram - Condensing Section, Cont.
RC/FC Series Installation, Operation, and Maintenance Manual