![ADDER SMARTView
MULTISCREEN SVMS2-QUAD Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/adder/smartview-multiscreen-svms2-quad/smartview-multiscreen-svms2-quad_installation-and-use-manual_2848769021.webp)
SmartView Multiscreen
Installation and Use
Page 20
Type of mouse / system
Driver type Likely expected
Suggested
Connected at bootup
data format
restoration
PS/2
PS/2 only
PS/2
F5
PS/2
IntelliMouse
PS/2
F5
IntelliMouse / SmartView MS
PS/2 only
PS/2
F5
IntelliMouse / SmartView MS
IntelliMouse
IntelliMouse
F6
To restore lost mouse movement on a CPU connected to the SmartView
Multiscreen:
1)
Select the CPU that has lost its mouse movement
2)
Press the select key on the front of the SmartView Multiscreen for 5 seconds until
‘C’ is displayed. You are now in configure mode.
3)
To restore a PS/2 mouse connection press
F 5
F 5 f
f
Or, to restore an IntelliMouse connection press
F 6
F 6 f
f
4)
Exit from configure mode by typing
E
E f
f
5)
Test the mouse movement by moving the mouse a short distance.
F5
- Restore PS/2 mouse function
F6
- Restore IntelliMouse function
2.12 Upgrading the SmartView's flash memory
The SmartView Multiscreen uses flash memory technology which enables the
firmware code to be upgraded by the user. Upgrades are performed by connecting a
PC's serial port to the SmartView's options port and running an upgrade program on
the PC. This upgrade program downloads the new firmware to the SmartView and
checks that the data has been programmed correctly.