page 5
ADDAC SYSTEM
SIMPLE VCO’s SETUP
So you just installed the Intuitive Quantizer in your
system and powered it up for the first time!
You saw the lights blinking showing the default
factory presets after which the default C Major scale
lits up on the keyboard area.
Assuming you immediately want to plug it to your
VCO’s you should plug cables from OUTS 1 to 4 to your
VCO’s (showing red in the image on the left). If you
have less than 4 VCO’s plug them 1 to X depending on
the VCO’s you have available at the moment.
After this Set all your VCO’s to the lowest Octave
possible and/or desired.
Next step to take is to tune all VCO’s among them-
selves. For this you’ll need to go into Keyboard Mode
pressing Button 1 for a couple seconds. Lights will go
all On besides the Active note being played.
(Read
At this point you should rotate the KEY/OCTAVE Knob to
F5 label and press C note in the keyboard (Button 1).
This will generate a 4V output in all OUT Jacks which
relates to a C note 4 octaves above the main octave
that you set your VCO to in the previous step.
So now that you have the same 4V going in all your
VCO’s Tune all them all to the same C note until they
play in Unison.
After this you can start playing a major C Scale in your
keyboard (like defined by the scale setting in the initial
Quantizer Mode) and all your VCO’s should still be in
tune.
Now you can also change the KEY/OCTAVE Knob to
play lower or higher octaves.
ADDAC207 INTUITIVE QUANTIZER
USER’S GUIDE
April.2021
Revision.05