provides fault isolation and troubleshooting procedures for the FPR-806.
Table 14. Fault Isolation and Troubleshooting
LED
State
Probable Cause
Solution
PWR
On
OK
Off
• No input power
• Shelf power fuse blown
• FPR-806 processor stopped
• Verify fuses on bay fuse panel
• Check input power on the COT Shelf
battery terminations
• Remove and re-insert FPR-806
• Replace the FPR-806
FAULT
On
Problem with the FPR-806
Replace the FPR-806
Flashing
PMX-744 card missing from shelf
Make sure PMX-744 is installed
Off
OK