L-854 Radio Control Equipment
96A0390 Rev.J
DISCLAIMER / WARRANTY
© ADB Airfield Solutions All Rights Reserved
20
7.
Action:
Depress CARRIER TEST Push-button seven times within 5 seconds.
Result::
The green 100 light next to ENERGIZED should come on. The 7-click relays
should close.
NOTE:
The configuration of SW1 will determine if the 3-click and 5-click relays will also
close.
8.
Action:
Wait approximately 60 seconds.
Result:
The 7-click relays should open. The green 10 light will go out.
9.
Action:
Return the TIMEOUT Switch to your normal setting. The FAA standard is 15
minutes.
10.
Action:
Enter the desired operating frequency (if different than shown on display) using
the
(down) and
(up) keys to the left of the LED frequency display. Press the
ENTER button once. After the displays shows VERIFY, press and hold the ENTER button
for five seconds to store the frequency in memory, and move the receiver to the desired
frequency.
Result:
Unit is now ready for operation.