F-Range Type L-850C Style 3 Inset Lights
Repair
2006 ADB Airfield Solutions, Incorporated
96A0285D
Page 6-3
All rights reserved
Issued 04/13
WARNING:
Turn off the circuit before replacing lamp(s).
Failure to observe this warning may result in personal
injury, death, or equipment damage.
WARNING:
Allow time for the unit to cool. High interior
temperatures may cause severe burns to personnel.
Refer to Table 6-1 for parts referred to in Figures 6-4, 6-5, 6-6, and
6-8.
Table 6-1 Parts List for Replacing Lamp and Filter
Item Part
Number
Description
Quantity
Note
Item 1 on
Figure 6-4
Optical
unit
1
44A6018-1
Optical unit, 1 lamp, right hand
44A6018-2
Optical unit, 1 lamp, left hand
44A6018-3
Optical unit, 2 lamps
Item 2 on
Figure 6-4
Inner pan assembly
1
44A6019-1
Inner pan assembly, 2 lamp, 1 cordset, without film
disc cutout
44A6019-2
Inner pan assembly, 2 lamp, 1 cordset, with film disc
cutout
44A6019-3
Inner pan assembly, 2 lamp, 2 cordsets, without film
disc cutout
44A6019-4
Inner pan assembly, 2 lamp, 2 cordsets, with film
disc cutout
44A6019-5
Inner pan assembly, left-hand lamp, 1 cordset,
without film disc cutout
44A6019-6
Inner pan assembly, left-hand lamp, 1 cordset, with
film disc cutout
44A6019-7
Inner pan assembly, right-hand lamp, 1 cordset,
without film disc cutout
44A6019-8
Inner pan assembly, right-hand lamp, 1 cordset, with
film disc cutout
Item 4 on
Figure 6-4
63A0222
Grommet (for optical bracket)
3
Item 5 on
Figure 6-4
7110.08.367
Screw, M4 x 10 (for optical bracket)
3
Continued on next page