952.476UK User Manual
Operation
Once all connections are made, turn all zone volume controls (1) to the
“
MIN
”
level (anticlockwise)
Select source
“
A
”
for each zone by keeping the source select button in the
“
out
”
position (2)
Select each zone output to be
“
off
”
by keeping the on/off switch in the
“
out
”
position (3)
Switch on the amplifier connected to IN A, play audio for testing and turn up the volume part way.
Enable Zone 1 on the AT6 by pressing in the on/off switch and gradually turn up the volume control.
Check to hear the audio through the speakers and move onto the same process for zones 2 to 6.
When all outputs have been checked for operation, adjust the amplifier and zone levels as required.
If a second amplifier is connected to IN B, turn all zone volume controls down before testing.
Switch on the second amplifier, play some audio through it and turn up the volume part way.
Press the source select button for each zone to the
“
in
”
position, selecting
“
B
”
as the input.
Gradually increase the volume control for each zone in turn, checking for output from the speakers.
When checking is complete, adjust the output of the amplifier and zone volume controls as required.
If the 24V EMG is connected to an emergency panel, test that it mutes all zone outputs upon alarm.
Specifications
Power handling
30W max. per output zone
Zone controls
11 position volume attenuator, A/B source selector, On/Off switch
Emergency control
24V mute terminals
Connections
IN A + B, OUT 1-6, 24V MUTE (Euroblock screw terminals)
Dimensions
482 x 160 x 43mm
Weight
2.39kg
Errors and omissions excepted.
Copyright© 2020. AVSL Group Ltd.
Disposal:
The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or
Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.
The goods must be disposed of according to your local council guidelines.