952.476UK User Manual 

Operation 

 
Once all connections are made, turn all zone volume controls (1) to the 

MIN

 level (anticlockwise) 

Select source 

A

 for each zone by keeping the source select button in the 

out

 position (2) 

Select each zone output to be 

off

 by keeping the on/off switch in the 

out

 position (3) 

 

Switch on the amplifier connected to IN A, play audio for testing and turn up the volume part way. 
Enable Zone 1 on the AT6 by pressing in the on/off switch and gradually turn up the volume control. 
Check to hear the audio through the speakers and move onto the same process for zones 2 to 6. 

When all outputs have been checked for operation, adjust the amplifier and zone levels as required. 
 
If a second amplifier is connected to IN B, turn all zone volume controls down before testing. 
Switch on the second amplifier, play some audio through it and turn up the volume part way. 

Press the source select button for each zone to the 

in

 position, selecting 

B

 as the input. 

Gradually increase the volume control for each zone in turn, checking for output from the speakers. 
 

When checking is complete, adjust the output of the amplifier and zone volume controls as required. 
 
If the 24V EMG is connected to an emergency panel, test that it mutes all zone outputs upon alarm. 

 
 

Specifications 
 

Power handling 

30W max. per output zone 

Zone controls 

11 position volume attenuator, A/B source selector, On/Off switch 

Emergency control 

24V mute terminals 

Connections 

IN A + B, OUT 1-6, 24V MUTE (Euroblock screw terminals) 

Dimensions 

482 x 160 x 43mm 

Weight 

2.39kg 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 

 

Errors and omissions excepted. 

 

Copyright© 2020. AVSL Group Ltd. 

 

 

Disposal:

 

The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or 

 

Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.  
The goods must be disposed of according to your local council guidelines. 

Содержание AT6

Страница 1: ...AT6 6 Zone 100V Attenuator Source Selector Item ref 952 476UK User Manual Version 1 0 Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Страница 2: ...uld cause damage to the amplifiers or the AT6 Each output of the AT6 has a maximum power rating of 30W Ensure that the combined tapped power of speakers connected to a single output does not exceed 30W Safety If liquids are spilled on the casing stop using the AT6 immediately allow the unit to dry out and have checked by qualified personnel before further use Avoid impact extreme pressure or heavy...

Страница 3: ...utput terminal from an amplifier to the terminal of IN A on the AT6 12 Connect the COM output terminal from the same amplifier to the terminal of IN A on the AT6 If another amplifier is to be used as a second source repeat the above steps for IN B terminals 10 Between the terminals for IN A and IN B are another pair of screw terminals labelled EMG 24V 11 These may be connected to the 24V trigger o...

Страница 4: ... turn up the volume part way Press the source select button for each zone to the in position selecting B as the input Gradually increase the volume control for each zone in turn checking for output from the speakers When checking is complete adjust the output of the amplifier and zone volume controls as required If the 24V EMG is connected to an emergency panel test that it mutes all zone outputs ...

Отзывы: