background image

 

952.476UK User Manual 

Front panel 
 

 

1.  Zone volume rotary switch controls 

 

2.  Source select (amplifier A / amplifier B) 

 

3.  Zone on/off switch 

 

 
Rear panel 
 

 

 

4.  Zone output 6 screw terminals - / + 

9.  Zone output 1 screw terminals - / + 

5.  Zone output 5 screw ter / - 

10.  Amplifier input B screw ter / - 

6.  Zone output 4 screw terminals - / + 

11.  24V emergency mute screw ter / - 

7.  Zone output 3 screw terminals - / + 

12.  Amplifier input A screw terminals - / + 

8.  Zone output 2 screw ter / - 

 

 

 

Connection and setup 
 

Connections for the AT6 are all on the rear panel and the screw terminals are on removable blocks 
for ease of installation. Ensure all connection polarities are correct as indicated on the rear panel. 

 
The AT6 can operate in conjunction with one or two 100V amplifiers as input sources. 
Connect the 100V output terminal from an amplifier to the 

+

 terminal of IN A on the AT6 (12) 

Connect the COM output terminal from the same amplifier to the 

-

 terminal of IN A on the AT6. 

 
If another amplifier is to be used as a second source, repeat the above steps for IN B terminals (10). 
 

Between the terminals for IN A and IN B are another pair of screw terminals labelled 

EMG 24V

 (11) 

These may be connected to the 24V trigger of an emergency panel to mute all outputs upon alarm. 
 

Take maximum care not to allow any shorted strands of wire across any of the terminals. 
 
All 100V speaker outputs are via screw terminals on 2 further removable blocks (4 

 9) 

Connect 100V speakers via the corresponding 

+

 and 

-

 output terminals on the AT6 

If more than 1 speaker is to be connected to a single zone output, connect these in parallel. 
Ensure that the total load of all speakers on a single output does not exceed 30W. 
 

Make sure all screw terminal blocks are firmly in place on the rear panel after making connections. 
 

Содержание AT6

Страница 1: ...AT6 6 Zone 100V Attenuator Source Selector Item ref 952 476UK User Manual Version 1 0 Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Страница 2: ...uld cause damage to the amplifiers or the AT6 Each output of the AT6 has a maximum power rating of 30W Ensure that the combined tapped power of speakers connected to a single output does not exceed 30W Safety If liquids are spilled on the casing stop using the AT6 immediately allow the unit to dry out and have checked by qualified personnel before further use Avoid impact extreme pressure or heavy...

Страница 3: ...utput terminal from an amplifier to the terminal of IN A on the AT6 12 Connect the COM output terminal from the same amplifier to the terminal of IN A on the AT6 If another amplifier is to be used as a second source repeat the above steps for IN B terminals 10 Between the terminals for IN A and IN B are another pair of screw terminals labelled EMG 24V 11 These may be connected to the 24V trigger o...

Страница 4: ... turn up the volume part way Press the source select button for each zone to the in position selecting B as the input Gradually increase the volume control for each zone in turn checking for output from the speakers When checking is complete adjust the output of the amplifier and zone volume controls as required If the 24V EMG is connected to an emergency panel test that it mutes all zone outputs ...

Отзывы: