background image

USER’S MANUAL                                                                                         V-line 899x.xxx/LPG 

 

17 

Dismount the covers, unscrew the bolts connecting the meter to the joining piece. Disconnect the flange 
connection to electromagnetic valve,  dismount the  bolts of the integrated detector and remove it from 
the meter. Reverse procedure is used for remounting the meter.                    

Dismantling of the electromagnetic valve 

Disassemble the covers of hydraulics, disconnect the joining tube by means of a cap nut. Then dismount 
the fixing bolts of the valve flange. Release the wires of electromagnetic spools in bushings after removing 
the covers of the hose module. Then disconnect the wires in the counter case and remove the valve after 
withdrawing the wires from the wire bundle. Reverse procedure is used for mounting the valve. 

9.11.

 

Maintenance instructions for dispenser body parts  

Good  appearance  of  dispensers  is  a  part  of  the  filling  station  standard.  Even  if  the  parts  of  external 
covering  have  either  been  provided  with  coats  of  good  quality  or  made  of  stainless  steel,  their 
maintenance  should  be  carried  out  regularly.  Instructions  for  use  specified  by  the  supplier  shall  be 
adhered  to. 

Higher attention should be paid to these parts in winter season because of unfavourable effect owing 
to aerosol from chloride agents used for road maintenance.  

Preservative polishing agents are recommended for the restoration of surfaces stained by fuel liquids. 
The maintenance of the dispenser covering is carried out by filling station operators. 
 

 

ATTENTION! 
For the maintenance of the dispenser covering use only agents recommended by the 
producer of fuel dispensers! Act upon instruction given on agents. 

 

 
Recommended time intervals for the maintenance of dispenser painted body parts: 

 

 

washing the dispenser with hot water  - twice per month at least (according to staining severity and 
season of the year) 

 

 

washing the dispenser with surfactant, proper cleaning of covers from salt residues, dust and grease 
with subsequent restoration of preservative coating on the body parts - once per month (according to 
the season of the year) 

 

washing  the  dispenser  with  surfactant  and    restoration  of  preservative  coating  is  also  recommended 
after more extensive surface staining by fuels 
 

Recommended time interval for the maintenance of stainless body parts: 

 

ATTENTION!  

DO NOT WASH STAINLESS STEEL SHEETS  

BY WATER OR EVEN SURFACTANT!!

 

Recommended procedure for stainless steel sheets: 

 

Washing of parts by thorough cleaning of salt residues, dust and 
grease followed by the renewal of  protective coating on body 
parts - by special agent for the protection of stainless steel 
sheet - once a month. 

 

Recommended special agents: 

-

 

NEOBLANK spray (producer: Chemische Fabrik Dr. Weight 
GmbH & Co. KG, Mühlenhagen 85 - D - Hamburg 

-

 

ANTOX Surface Care 800 S (producer: Chemetall AG, 
Silostrasse 7, CH - 5606, Dintikon 

-

 

ULTRAPUR – d ( producer: MMM – Group, SRN) 

 

 

Содержание MINOR LPG

Страница 1: ...16 519 201 F 420 516 519 102 sales adastsystems cz www adastsystems cz OÚ 005 2005 A XII 2016 USER S MANUAL Instructions for Operation Maintenance and Installation LPG Dispenser for Dispensing of Liquiefied Propane butane POPULAR LPG MINOR LPG V line 899x xxx LPG ...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ... Design with heating of the electronic case 8 5 TECHNICAL DATA 8 6 IDENTIFICATION 9 6 1 Rating plate of the LPG fuel dispenser V line 899x xxx LPG 9 7 FILLING OF LIQUEFIED GAS INTO MOTOR VEHICLES 10 7 1 Dispensing with service 10 7 2 Self dispensing 11 7 3 Dispensing with preselection 11 7 4 Description of the preselection function 12 8 FUNCTION OF KL MANINF MANAGER KEYBOARD OR KL SERINF ONE 12 8 ...

Страница 6: ...SPENSER 18 13 TRANSPORT 19 14 DISPENSER INSTALLATION 19 14 1 Hydraulic section 19 14 2 Wiring 20 15 PUTTING OF THE DISPENSER INTO OPERATION 21 15 1 Putting of the dispenser and electronic counter into operation 21 15 2 Shutdown of the dispenser and electronic counter 21 15 3 Restart of the dispenser and electronic counter after power failure and voltage drop 21 16 PACKING AND STORAGE 21 16 1 Packi...

Страница 7: ...9 10 1 Important instructions for installation and operation a Prior to proceed to the dispenser handling study these Operating User s manual and other manufacturer s documents belonging to the dispenser accessories carefully b Check the dispenser delivery for completeness and in the case of any discrepancy or damage inform supplier or the manufacturer without delay c Ensure the proper storage of ...

Страница 8: ... certification according to the annex III of the Directive 2014 34 EU ATEX by an authorised body FTZÚ Pikartská 7 716 07 Ostrava Radvanice Notified body no 1026 EC Type Examination Certificate No FTZÚ 05 ATEX 0222 Regular inspection of production quality assurance according to supplement no 4 to SO no 23 2003 executes FTZÚ s p Ostrava Radvanice NO no 1026 Notification of quality assurance No FTZÚ ...

Страница 9: ...diately In the case of a small leak of gas the filling station operators check the whole system and if they do not detect any failure ventilate the gas leaked small leakage when connecting and disconnecting the dispensing hose effect of exhaust gases and put the system into the operation again In the case of a higher concentration of leaked gas the evaluating unit puts the electrical system out of...

Страница 10: ...ctronic counter case The colour shade of the door including the logo can be optional Both doors are lockable being unlocked swing out and with earth wire disconnected they can be removed and thus the hydraulic part is accessible Connect the earth wires when the door is fitted back A junction box is built in into the supporting column and is accessible after dismounting the side cover of the column...

Страница 11: ...pening the cover ATTENTION Before opening the covers it is always necessary to disconnect power to the dispenser and perform a reliable hedge against its re connection The dispensing nozzles are seated in covers in the V form pressed shape of the column When the dispenser is out of operation the dispensing nozzles in covers can be locked 4 3 Hydraulic system of the LPG fuel dispenser Poition Hydra...

Страница 12: ...e separator from the bottom for the dispensers designed with automatic temperature compensation of dispensed volume in relation to its momentary temperature ATC A metrological branch with a spherical cock G 1 2 for metrological verification and service purposes is a part of the separator return piping A piston meter fitted with a sensor of impulses transmitted to the counter is connected to the se...

Страница 13: ...blets for ATC on designed medium type of fuel can be integrated into SW of electronic counter by customer request Setting of calibration EC or ATC is provided by using of service keyboard KL SERINF and setting of proper calibrating switches DIP on body of electronics counter as per instructions described in manual of electronic counters ADP1 T ADP2 T ADP1 L Providing of calibration is allowed to a...

Страница 14: ...ey combine the basic functions of the filling station i e sale of fuels sale of dry goods and their filing The POS system is also able to operate even as a multi cash one i e its individual parts can be interconnected in the communication SW network two backoffices and three tills if more than five backoffices or tills are connected a server has to be included 4 6 Signalling of dispenser condition...

Страница 15: ...in 1 Min flow rate Qmin 8 dm3 min 1 Max flow rate Q dispensed from one nozzle 40 dm3 min 1 Operating flow rate by dispensing from both nozzles DUO Q 2 x 30 dm3 min 1 Operating flow rate by dispensing from four nozzles QATTRO Q 4 x 30 dm3 min 1 Min measured quantity MMQ 5 dm3 5 4 Technical parameters of the fuel dispenser LPG DUPLEX V line 8994 6x2 LPG Max flow rate Qmax 40 dm3 min 1 Min flow rate ...

Страница 16: ... the group and category of the device explosion and temperature categories of dispensed fuels II2G IIAT3 21 Standard for fuel dispensers EN 14678 1 22 Electrical parameters Values of electronics heating and el motors feeding 7 FILLING OF LIQUEFIED GAS INTO MOTOR VEHICLES The construction of dispenser meets the high requirements of simplicity and comfort commissioning by pressing a button or turnin...

Страница 17: ...g IMPORTANT WARNING In case the tank is filled to be full most frequent case the automatic safety level regulation controlling the filling of the tank to 80 max shuts off the supply by means of a mechanical limiter without respect to manual push button control 7 2 Self dispensing ATTENTION Dispenser for self service must be within the meaning of Article no 4 5 8 EN 14678 1 provided with a means en...

Страница 18: ...nt case the automatic safety level regulation controlling the filling of the tank to 80 max shuts off the supply by means of a mechanical limiter without respect to manual push button control Non dispensed preselected volume is reset after 20 seconds approximately 8 FUNCTION OF KL MANINF MANAGER KEYBOARD OR KL SERINF ONE The KL MANINF manager keyboard and the KL SERINF service keyboard are deliver...

Страница 19: ...price 5 Whenever the user can terminate the setting of the unit price values by depressing the 0 key 6 Now the unit price values have been written in non volatile storage in this way and the counter sets the MAN mode 8 2 Setting of unit price values from the control system in AUTO mode In AUTO mode the unit price values are set from the control system for all transactions independently on unit pri...

Страница 20: ...ser and its individual components ensure inspection testing repairs and maintenance by qualified methods carry out records and file documents ATTENTION All repairs of operating units can only be carried out by a service repair shop and their serviceman with relevant authorisation Repairs changes and dismantlings of undermentioned dispenser units depends of the perfect propane butane displacement w...

Страница 21: ...ressure the pressure release valve will connect the pipe between the separator and the meter to the interior of the separator which results in pressure fall in the meter ATTENTION Only a qualified labourer of the service shop may be charged with repairs of the separator assembly and prospective replacement of the filter 9 4 Electromagnetic two stage valve It is used for two stage closing of flow w...

Страница 22: ...e carried out by the filling station operator Replacement of sealing and the nozzle itself can be only carried out by a skilled worker of the service shop 9 10 Dismantling of covers It is carried out in required scope during installation routine maintenance minor repairs and modifications of electric or hydraulic parts The original location of covers must be held in remounting Covering of MONO DUO...

Страница 23: ...s are recommended for the restoration of surfaces stained by fuel liquids The maintenance of the dispenser covering is carried out by filling station operators ATTENTION For the maintenance of the dispenser covering use only agents recommended by the producer of fuel dispensers Act upon instruction given on agents Recommended time intervals for the maintenance of dispenser painted body parts washi...

Страница 24: ...in the filling station switchboard 3 Prior to any intervention propane butane shall be expelled by nitrogen from the complete system except storage tanks including LPG dispenser 4 Both valves in the LPG supply line from the storage tank in the return line to the storage tank must be closed 5 For the period of the service intervention any motor vehicle traffic has to be avoided within 5 m radius an...

Страница 25: ...ee any prospective damage 14 DISPENSER INSTALLATION The dispenser can be joined only to process equipment tanks piping of perfect tightness and cleanness The supplier of the process equipment is responsible for its tightness and cleanness The dispenser installation is carried out by the organisation authorised by the manufacturer Prior to the installation the organisation shall perform the inspect...

Страница 26: ... of the liquid and gaseous phases should be anchored to the lower machinery in the shaft under the dispenser Approved breakage coupling is delivered on special request of the Client 14 2 Wiring Earthing conductor shall be connected to the shaft under every dispenser Leads to the dispenser must be sealed to prevent its interior from the penetration of combustible liquids or vapours Only cable termi...

Страница 27: ...he switchboard of the filling station off feeding the electronics and el pump motor 15 3 Restart of the dispenser and electronic counter after power failure and voltage drop In case of power failure or voltage alteration beyond acceptable limits the information about the volume and price of the fuel dispensed within the interval from the last button pressing or switch over of switch into the ON po...

Страница 28: ...not cover the consumables for instance fluorescent lamps filter Guarantee and reclamations are defined on contract Тhe fuel dispenser can be reclaimed only at the dealer where the customer bought this dispenser 18 SPARE PARTS CATALOGUE Spare parts catalogues of the dispenser are supplied to service organisations The user can request the spare part catalogues from the manufacturer 19 ACCESSORIES Pa...

Страница 29: ... LPG with ADP T counter to the filling station switchboard Enclosure No 14 Connection of V line 8991 623 LPG dispenser without the conduit box to the filling station switchboard Enclosure No 15 Connection of the fuel dispenser V line 8991 6x4 LPG with mechanical counter to the filling station switchboard Enclosure No 16 Connection of the fuel dispenser heating to the filling station switchboard va...

Страница 30: ......

Страница 31: ...USER S MANUAL V line 899x xxx LPG Enclosure No 1 Main dimensions of dispensers V line popular 899x xxx LPG ...

Страница 32: ...USER S MANUAL V line 899x xxx LPG Enclosure No 2 Main dimensions of dispensers V line minor 899x xxx LPG Min distances of the dispenser from a steady obstacle located at the filling station ...

Страница 33: ...USER S MANUAL V line 899x xxx LPG Enclosure No 3 View of dispensers V line 8991 6x2 LPG series View of dispensers V line 891x 6x3 LPG series ...

Страница 34: ...USER S MANUAL V line 899x xxx LPG Enclosure No 4 View of dispensers V line 8992 6x2 LPG series View of dispensers V line 8995 6x2 LPG series ...

Страница 35: ...USER S MANUAL V line 899x xxx LPG Enclosure No 5 Installation dimensions of V line 8991 xxx LPG and V line 8995 xxx LPG dispensers ...

Страница 36: ...USER S MANUAL V line 899x xxx LPG Enclosure No 6 Installation dimensions of V line 8994 xxx LPG and V line 8994 xxx LPG dispensers ...

Страница 37: ...USER S MANUAL V line 899x xxx LPG Enclosure No 7 Installation dimensions of V line 8991 6x3 LPG ...

Страница 38: ...USER S MANUAL V line 899x xxx LPG Enclosure No 8 Areas with risk of gas pressure release or residual nitrogen at the separator used in the hydraulic circuit of V line 899x xxx LPG dispensers ...

Страница 39: ...uits and dispenser electronic equipment must be galvanic separated from the mains and even from protective conductors a system of swimming zero is created 6 To comply with the requirement under item 5 the proper UPS must have galvanic separated input and output circuits 7 For feeding of electronic system of the filling station the UPS of ON LINE type must be used exclusively 8 For the correct func...

Страница 40: ...USER S MANUAL V line 899x xxx LPG Enclosure No 10 Connection of the fuel dispenser V line 8991 xxx LPG V line 8993 xxx LPG and V line 8995 xxx LPG to the filling station switchboard ...

Страница 41: ...USER S MANUAL V line 899x xxx LPG Enclosure No 11 Connection of the fuel dispenser V line 8992 xxx LPG and V line 8994 xxx LPG to the filling station switchboard ...

Страница 42: ...USER S MANUAL V line 899x xxx LPG Enclosure No 12 Connection of the fuel dispenser V line 8991 xx3 LPG with ADP1 L counter to the filling station switchboard ...

Страница 43: ...USER S MANUAL V line 899x xxx LPG Enclosure No 13 Connection of the fuel dispenser V line 8991 xx3 LPG with ADP1 T counter to the filling station switchboard ...

Страница 44: ...USER S MANUAL V line 899x xxx LPG Enclosure No 14 Connection of V line 8991 623 LPG dispenser without the conduit box to the filling station switchboard ...

Страница 45: ...USER S MANUAL V line 899x xxx LPG Enclosure No 15 Connection of the fuel dispenser V line 8991 6x4 LPG with mechanical counter to the filling station switchboard ...

Страница 46: ...USER S MANUAL V line 899x xxx LPG Enclosure No 16 Connection of the fuel dispenser heating to the filling station switchboard valid only for the fuel dispenser with electronic case heating ...

Страница 47: ... the magnetic pulse transmitter ME 01 05 ME 01 05 05 MTX 075 and ADAST 40 to the electronic counter ADP1 L connector X1 Magnetic pulse transmitter ME 01 05 Magnetic pulse transmitter ME 01 05 05 Magnetic pulse transmitter MTX 075 Magnetic pulse transmitter ADAST 40 ...

Страница 48: ...USER S MANUAL V line 899x xxx LPG Enclosure No 18 Connection of the magnetic pulse transmitter ME 01 05 ME 01 05 05 MTX 075 and ADAST 40 to the electronic counter ADP1 T ADP2 T connector X2 ...

Страница 49: ...V line 899x 6х3 LPG The inner space of the LPG dispenser hydraulic housing ZONE 1 The outside space of the hydraulic housing within 50 mm above the top edge of the housing and within 200 mm horizontally in all directions down to the ground ZONE 2 The electronic counter casing anchored to hydraulic housing is separated by horizontal barrier type 1 The casing is designed with protection degree IP67 ...

Страница 50: ...nclosure No 20 Hazardous zones of LPG dispensers V line 899х 6х2 LPG Hazardous zones of LPG dispensers V line 8991 6х2 LPG V line 8995 6х2 LPG Hazardous zones of LPG dispensers V line 8993 6х2 LPG V line 8994 6х2 LPG V line 8992 6х2 LPG ...

Страница 51: ...USER S MANUAL V line 899x xxx LPG Enclosure No 21 Hazardous zones of LPG dispensers V line 899х 6х3 LPG Hazardous zones of LPG dispensers V line 8991 6х3 LPG ...

Страница 52: ...USER S MANUAL V line 899x xxx LPG Enclosure No 22 Type marking on the dispenser rating plate V line 899x xxx LPG ...

Страница 53: ...USER S MANUAL V line 899x xxx LPG Enclosure No 23 Type marking on the dispenser rating plate V line 899x xxx LPG CA ...