USER’S MANUAL V-line AdBlue
®
47xx.xxx
10
Providing of calibration is allowed to authorised person, only. The DIP calibration switches must be fixed by
plomb after calibration finish.
Displays: LCD type with BACK LIGHT illumination
LCD displays with
BACK LIGHT DISPLAY
(BLD)
illumination
are used especially for their good readability.
The duration of data holding on the display after supply voltage failure is 30 minutes at least. Decimal point
on BLD display devices is represented automatically in accordance with the setting of parameters.
Lighting
LED diodes are used for the illumination of displays at dispensers.
ON / OFF switching of the illumination is automatically carried out with the activation of electronics.
Totalizer:
non-resettable electronic counter of dispensed volume and its price – 11 digits – or non-
resettable electromechanical counter of dispensed volume – 7 digits.
Electronic counter of ADPMPD/T, ADPMPD/T-PWM, ADP1/T, ADP2/T, ADP1/L
series
operates with a 2-
channel impulse generator producing 2x 100 impulses per 1 dm
3
. The HW and SW counters of the
ADPMPD/T, ADP1/T, ADP2/T, ADP1/L
series enable high metering accuracy and the application of the
electronic calibration using the 2-channel impulse generator.
IMPORTANT NOTICE:
Connection of the magnetic pulse transmitter ME 01-05, ME 01-05-05, MTX 076 and ADAST 41 to the
electronic counter ADP1/L (connector X1), electronic counter ADP1/T, ADP2/T (connector X2) and
electronic counter ADPMPDx/T, ADPMPDx/T-PWM (connector X3) - see enclosure 8, 9, 10.
The local electronic preselection system
in IP67 design is integrated into the counter case. The
preselection enables the Customer’s preselection of the exact volume or the price of the product to be
dispensed. The two-stage or proportional electromagnetic valves ensure the closing of flow and exact
dispensing of the preselected volume / price and smooth initiation of dispensing.
The fuel dispensers can be equipped with ADAMAT filling automatic equipment. This equipment enables
dispensing and payment of the product by means of contactless, magnetic and chip cards including receipt
printing. This equipment undertakes simultaneously all functions of the dispenser electronic counter for
non-public and public dispensing. The electronics of the filling automatic equipment can be complemented
by the ADPMPD/T, ADPMPD/T-PWM, ADP1/T, ADP2/T, ADP1/L
electronic counter with public dispensing.
The fuel dispenser is connected through a communication line to the control system, which controls the
operation of the whole filling station (releasing of dispensers, volume preselection, unit price variation,
self-diagnosis, etc.). The dispensers can be operated even at the filling stations without any control system
– i.e. in serviced operation.
Circuit diagrams for the connection of individual dispenser types to the switchboard of the filling station –
see enclosures.
4.4.1
Communication to the control system
The
ADP1/T, ADP2/T, ADP1/
calculator can operate independently and/or can be controlled by a site
control system.
The calculator is connected to the site control system via the RS-485 line, which is controlled by its own
communication protocol EASY-CALL, and /or according to IFSF standards (communication level LON or
TCP/IP- Ethernet).
Communication to different control systems shall be consulted with the manufacturer of the dispensers
in advance.
The fuel dispensers connected to the control system can be operated in the mode of volume preselection or
the financial sum preselection from the control system
(the dispensers have to be equipped with two-
stage or proportional electromagnetic valves).
4.5.
Signalling of dispenser conditions (SO)
On Client’s special requirement the fuel dispenser can be equipped with a red signal light, which gives
information to the customer and the operator about the present dispenser condition – the dispenser is
blocked or ready for fuel filling.
Содержание AdBlue V-line 47 Series
Страница 2: ......
Страница 11: ...USER S MANUAL V line AdBlue 47xx xxx 7 Figure 2 ...
Страница 28: ......
Страница 29: ...USER S MANUAL V line AdBlue 47xx xxx Enclosure No 1 View of dispensers ADAST MAJOR V line R AdBlue 47xx xxx ...
Страница 30: ...USER S MANUAL V line AdBlue 47xx xxx Enclosure No 2 Main dimensions of dispensers V line R AdBlue 47xx xxx ...
Страница 33: ...USER S MANUAL V line AdBlue 47xx xxx Enclosure No 5 ...
Страница 46: ...USER S MANUAL V line AdBlue 47xx xxx Enclosure No 18 The model marking on the V line R AdBlue 47xx xxx CA ...