Adaptive® JUNIOR – Technical and HMI User Guide
REV 1.04
26
The following tables lists the registers available in the JUNIOR with a brief description and any restrictions.
Register Number
Type
Limits
Description
0
Integer
Read only
Firmware Version number
1
Integer
See Table 7
Status
2
Integer
0 to 4
Control mode
0 = OFF
1 = Manual
2 = Thermostat
3 = PID
4 = Auto tune
3
Integer
0 to 3
Output drive option
0 = Positive only
1 = Negative only
2 = Bidirectional
3 = TRIAC output
4
Floating point
-50 to +250°C
Setpoint
5
Floating point
-10000.0 to +10000.0
Proportional gain term
6
Floating point
-10000.0 to +10000.0
Integral gain term
7
Floating point
-10000.0 to +10000.0
Differential gain term
8
Floating point
-10.0°C to +10.0°C
Hysteresis
9
Floating point
-10.0°C to +10.0°C
Deadband
10
Integer
0 to 255
Slew rate on output
0 = none
1 = max
255 = min
11=A, 12=B, 13=C, 14=D
Integer
0 to 2
Temperature sensor type connected to input (x)
0 = None
1 = K type
2 = NTC Thermistor
15=A, 16=B, 17=C
Floating point
-100000.0 to +100000.0
Steinhart Coefficient (x) for sensor A
18=A, 19=B, 20=C
Floating point
-100000.0 to +100000.0
Steinhart Coefficient (x) for sensor B
21=A, 22=B, 23=C
Floating point
-100000.0 to +100000.0
Steinhart Coefficient (x) for sensor C
24=A, 25=B, 26=C
Floating point
-100000.0 to +100000.0
Steinhart Coefficient (x) for sensor D
27=A, 29=B, 31=C, 33=D
Integer
-1000 to +1000°C
Temperature alarm low limit for sensor (x)
28=A, 30=B, 32=C, 34=D
Integer
-1000 to +1000°C
Temperature alarm high limit for sensor (x)
35
Integer
See Table 8
Temperature alarm enables
36
Integer
See Table 8
Temperature relay enables
37
Integer
See Table 8
Temperature shutdown enables
38
Integer
See Table 9
Current temperature alarm status
39=1, 47=2, 55=3
Integer
0 to 3
Fan Type for fan (x)
0 = None
1 = 2 Wire
2 = 3 Wire
3 = 4 Wire
40=1, 48=2, 56=3
Integer
0 to 2
Fan Mode
0 = OFF
1 = PWM
2 = RPM
41=1, 49=2, 57=3
Integer
0 to 16000 RPM or
0 to 100% PWM
Speed demand for fan (x)
42=1, 50=2, 58=3
Integer
0 to 5000mA
Fan (x) over current alarm limit
43=1, 51=2, 59=3
Integer
0 to 50V
Fan (x) over voltage alarm limit
44=1, 52=2, 60=3
Integer
0 to 16000 RPM
Fan (x) lower speed alarm limit
45=1, 53=2, 61=3
Integer
0 to 16000 RPM
Fan (x) upper speed alarm limit