background image

 

 

© Adam Equipment Company 2009 

 
ADAM  EQUIPMENT

  is  an  ISO  9001:2000  certified  global  company  with  more 

than  35  years  experience  in  the  production  and  sale  of  electronic  weighing 
equipment.  
 
Adam  products  are  predominantly  designed  for  the  Laboratory,  Educational, 
Medical, retail and Industrial Segments. The product range can be described as 
follows: 
 

-Analytical and Precision Balances 
-Compact and Portable Balances 
-High Capacity Balances 
-Moisture analysers / balances 
-Mechanical Scales  
-Counting Scales 
-Digital Weighing/Check-weighing Scales 
-High performance Platform Scales  
-Crane scales 
-Medical Scales 
-Retail Scales for Price computing 

 

For a complete listing of all Adam products visit our website at 

www.adamequipment.com 

 

©  Copyright  by  Adam  Equipment  Co.    All  rights  reserved.    No  part  of  this  publication  may  be 
reprinted  or  translated  in  any  form  or  by  any  means  without  the  prior  permission  of  Adam 
Equipment. 

 

Adam Equipment reserves the right to make changes to the technology, features, specifications 

and design of the equipment without notice. 

 

All information contained within this publication is to the best of our knowledge timely, complete 

and accurate when issued.  However, we are not responsible for misinterpretations which may 

result from the reading of this material. 

 

The latest version of this publication can be found on our Website. 

 

www.adamequipment.com

 

 

Содержание WBW 16/35a

Страница 1: ...cycled materials and environmentally friendly packaging where possible As part of this initiative we have developed a short manual that uses less paper and ink to describe the main functions of your new Adam indicator scale A complete version is available at www adamequipment com Thank you for your support of Adam Equipment and we hope that you enjoy your new scale ...

Страница 2: ... Adam Equipment Company 2009 ...

Страница 3: ... 2 0 OPERATION 2 2 1 NUMERIC ENTRY METHOD 2 2 2 ZEROING 2 2 3 TARING 2 2 4 WEIGHING 3 2 5 CHECK WEIGHING 3 3 0 RS 232 SPECIFICATION 4 4 0 CALIBRATION 4 5 0 ERROR CODES 5 6 0 SPECIFICATIONS 6 7 0 ERROR MESSAGES 9 8 0 MENU STRUCTURE 10 9 0 WARRANTY INFORMATION 11 10 0 SERVICE INFORMATION 12 ...

Страница 4: ...it of weight that was selected last NOTE the scale can be operated from the battery If desired the battery life is approximately 50 hours When the battery needs charging a symbol on the display will turn on The battery should be charged for 12 hours for full capacity 2 0 OPERATION 2 1 NUMERIC ENTRY METHOD To set a value when required use the keys as given below Limit key to increase the flashing d...

Страница 5: ... high limit The user will be asked for the password if the current check weighing password is anything other than 0000 See the parameter F4 PS in menu structure Enter the correct password using the numeric entry method as mentioned in section 2 1 If the password is 0000 it will display the last used high limit The HI symbol will appear on the display Press Tare to accept the displayed high limit o...

Страница 6: ...f test Scale will show P Enter code number 0000 using the numeric entry method see section2 1 and press Tare This will take you directly to the calibration section Display will show UnLoAd Remove all weight from the pan and then press the Tare key when the scale is stable After the Zero point is set the display will show Ld xx Place the suggested calibration mass on the pan It is best to use a wei...

Страница 7: ...hen zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 Err 6 Err 6 Err 6 A D count is not correct when turning the scale on Load cell is damaged Electronics is damaged Err 8 Err 8 Err 8 Err 8 High limit input error Low limit is set first then the high limit is set lower than the low limit and high limit not equal to zero Err 9 ...

Страница 8: ...ograms Maximum Capacity 2 000 kg 4 000 kg 8 000 kg 16 000 kg Tare Range 2 000 kg 4 000 kg 8 000 kg 16 000 kg Readability 0 0002 kg 0 0005 kg 0 001 kg 0 002 kg Repeatability S D 0 0002 kg 0 0005 kg 0 001 kg 0 002 kg Linearity 0 0004 kg 0 001 kg 0 002 kg 0 004 kg Grams Maximum Capacity 2000 g 4000 g 8000 g 16000 g Tare Range 2000 g 4000 g 8000 g 16000 g Readability 0 2 g 0 5 g 1 g 2 g Repeatability ...

Страница 9: ...S D 0 01 oz 0 02 oz 0 05 oz 0 1 oz Linearity 0 02 oz 0 04 oz 0 1 oz 0 2 oz Pounds Ounces Maximum Capacity 5 lb 0 00 oz 9 lb 0 00 oz 18 lb 0 0 oz 35 lb 0 0 oz Readability 0 01 oz 0 02 oz 0 1 oz 0 1 oz Repeatability S D 0 01 oz 0 02 oz 0 1 oz 0 1 oz Linearity 0 02 oz 0 04 oz 0 2 oz 0 2 oz OTHER SPECIFICATIONS Units of measure WBW M kg g WBW WBW a kg g lb oz lb oz Tare Full range Stabilisation Time 2...

Страница 10: ...CD digital display with capacity tracker and symbols for units Scale Housing IP 65 Sealed ABS Plastic housing with Stainless Steel pan Pan Size 210 x 173 mm Overall Dimensions wxdxh 231 x 265 x 153 mm Net Weight 3 3 kg 7 26 lb Applications Weighing Scales Functions Weighing Check weighing ...

Страница 11: ... on the platform when turning the indicator on Excessive weight on the platform when zeroing the indicator Platform is not installed Improper calibration of the indicator Damaged load cell Damaged Electronics Err 6 A D count is not correct when turning the indicator on Load cell is damaged Electronics is damaged Err 7 Percent input error Percent function is entered with no reference mass on the pl...

Страница 12: ...P a g e 10 Adam Equipment Company 2009 8 0 MENU STRUCTURE ...

Страница 13: ... the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted re...

Страница 14: ...her methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale WBW_____ Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of t...

Страница 15: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to oper...

Страница 16: ...s Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features ...