9.0
RS-232
INTERFACE
The Warrior indicator is supplied with bi-directional RS-232 interface as
standard. The scale, when connected to a printer or computer outputs the
weight with the selected weighing unit through the RS-232 interface.
Specifications:
RS-232 serial interface plug (As viewed from the back of the indicator):
1: Pin GND, Signal Ground
2: Pin RXD, Received Data
3: Pin TXD, Transmitted Data
4: Not connected
The scale can be set to print text in English, French, German or Spanish. See
the RS-232 parameters section for details.
RS-232 output of weighing data
ASCII code
600 - 19200 Baud (user selectable, default 9600)
8 data bits
No Parity
1 stop bit
No flow control