EN
© Adam Equipment Company 2015
33
3016612481Rev2.00-Jul15
The parameters that can be set are:
EnAbLE
EnAbLE
EnAbLE
EnAbLE
On = serial port enabled
OFF = serial port disabled
bAvd
bAvd
bAvd
bAvd
Set Baud Rate. Selectable values:
4800
4800
4800
4800
,
9600
9600
9600
9600
,
19200
19200
19200
19200
or
38400
38400
38400
38400
PARITY
PARITY
PARITY
PARITY
Set Parity. Selectable values:
nOnE
nOnE
nOnE
nOnE
,
EVEN
EVEN
EVEN
EVEN
or
ODD
ODD
ODD
ODD
STABLE
STABLE
STABLE
STABLE
ON = print only when reading is stable
OFF = print regardless of stability
CONTIN
CONTIN
CONTIN
CONTIN
ON = Send data continuously over serial port
OFF = Only send data when [PRINT] is pressed
PErIOd
PErIOd
PErIOd
PErIOd
ON = Set the RS-232 to send data periodically. Range 1 to 999 seconds
OFF = No periodic data transmission
FORMAT
FORMAT
FORMAT
FORMAT
Format of serial output data. Selectable parameter from:
SINGLE = Serial data output sent as a single line
STANDARD = Serial data output sent in standard format
FORM 1 = Serial data output sent in custom-designed format FORM 1
FORM 2 = or FORM 2 (See section 13.4).
13.4 FORMAT OF CUSTOM FORMS #1 and #2
If FORM1 or FORM2 is selected, the format be changed by the user using a selection of
available data. By default the 2 forms are the same as the standard form unless changed
by the user as below.
When “
FORMM1
FORMM1
FORMM1
FORMM1
“ or “
FORMM 2
FORMM 2
FORMM 2
FORMM 2
“ is selected, the user can set the information to be printed on
each line of the form. Pressing the [Up] or [Down] keys will cycle through the options
available. The options are:
INST ID
INST ID
INST ID
INST ID
Instrument ID number
SER No
SER No
SER No
SER No
Serial Number
TIME
TIME
TIME
TIME
Time
DATE
DATE
DATE
DATE
Date
NET
NET
NET
NET
Net Weight (Gross weight – Tare Weight)
GROSS
GROSS
GROSS
GROSS
Gross Weight
TARE
TARE
TARE
TARE
Tare Weight
vNiT
vNiT
vNiT
vNiT
Unit weight in parts counting mode
CoV
CoV
CoV
CoVNT
NT
NT
NT
Number of items in parts counting mode
REF
REF
REF
REF
100% weight in percent weighing mode
PER
PER
PER
PER
Percentage of reference weight in percent weighing
LO LIM
LO LIM
LO LIM
LO LIM
Low Limit when check weighing (Not used)
HI LIM
HI LIM
HI LIM
HI LIM
High Limit when check weighing (Not used)
CR LF
CR LF
CR LF
CR LF
Inserts a blank line
END
END
END
END
Signifies the end of the report
(When END is entered the display returns to the
SERIAL
SERIAL
SERIAL
SERIAL
Sub-menu)
Enter the data to be printed on the first line by pressing [Up] or [Down] to cycle through
the options. If the current information is OK then press [Setup] to move to the next line.
e.g. “
LINE 01
LINE 01
LINE 01
LINE 01
”, “
DATE
DATE
DATE
DATE
” – will print date on first line of output form.