EN 

© Adam Equipment Company 2018

 

 

2.0  INTRODUCTION

 

Thank you for purchasing your new 

Highland

TM

 

portable balance, Every 

Highland

TM

 

balance has all the features you really need: DC adapter and internal rechargeable 
battery, 

HandiCal

TM

 calibration (not available on approved models), backlit display, 

and 

ShockProtect

TM

  with  overload  indicator.  With  RS‐232  and  USB  interface  for 

communication  with  printers  and  computers,  splash‐proof  keypad,  and  sturdy 
plastic construction, the 

Highland

TM

 series will be a balance you can rely upon. We 

hope that you enjoy using your new balance. 

Before  operating  parts  marked  with  a 

 

 

!

       

  symbol  please  read  the  instruction  manual 

and operate with caution to avoid hazard. 

NOTE

: External metal parts and connectors are not linked to earth. 

NTEP  Approved  models,  HCB  aM

,  have  calibration  controlled  by  jumpers  or 

passcodes and other limitations as noted in the manual. 

3.0  SET

 

UP 

3.1 

UNPACKING

 

AND

 

SETTING

 

UP

 

YOUR

 

BALANCE 

1)

 

Remove the balance, draft shield, top pan, DC adapter and pan support from 
the packaging  

2)

 

Remove  the  shipping  protection  screw  and  transit  disc  from  the  top  of  the 
balance  and  place  the  plastic  top  pan  support  on  the  balance.  Do  not  use 
excessive force when removing and installing the screw.  

 

3)

 

Gently place the plastic pan support into the receptacle and secure with the 
supplied screw.  To not over‐tighten the screw. It should be finger tight only.     
Put the Stainless steel pan on top of the pan support 

Содержание HCB 1002

Страница 1: ...EU NTEP approved models HCB Software ver 2 33 or higher standard models HCB M Software rev 2 39 EU approved models HCB aM Software rev 3 11 NTEP approved models 99 Washington Street Melrose MA 02176 P...

Страница 2: ...am Equipment Company 2018 2 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and...

Страница 3: ...UNCTIONS 11 5 1 PERCENTAGE WEIGHING 11 5 2 PARTS COUNTING 11 5 3 ACCUMULATION 12 6 0 PARAMETERS 14 6 1 ENABLING WEIGHING UNITS 14 6 2 SETTING THE BACKLIGHT AND AUDIBLE ALERT BEEP 16 6 3 SETTING THE PR...

Страница 4: ...se read the instruction manual and operate with caution to avoid hazard NOTE External metal parts and connectors are not linked to earth NTEP Approved models HCB aM have calibration controlled by jump...

Страница 5: ...his key will move the flashing digit to the right Smpl Use this key to enter parts counting mode from the normal weighing mode When in parts counting pressing the Smpl will return to weighing mode Cle...

Страница 6: ...scharge time is approximately 24 hours depending on the usage of the backlight The display will show an indication when the battery needs to be charged To charge the battery plug in the DC adapter at...

Страница 7: ...u should disconnect the power supply if it is not going to be used for an extended period Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause c...

Страница 8: ...them easily on top of each other To save space and protect them from damage Without Shield With Shield Note Only models equipped with a 4 7 120mm pan can be stacked for storage Core CQT models with th...

Страница 9: ...rectly and that there is no weight on the pan or the internal calibration weight not approved models has not been left in the calibrate position Move the lever all the way to the left Turn off the bal...

Страница 10: ...function 4 3 WEIGHING To determine the weight of a sample first tare an empty container if used then place the sample in the container The display will show the weight of the sample and the unit of we...

Страница 11: ...increments and the balance is set to 100 the display will show 100 00 However a small change of weight will cause the display to jump to 102 13 as one balance division 0 5g increase to 24 0g will be e...

Страница 12: ...he balance is set for automatic accumulation see Parameters 6 3 Setting the Printer Parameters Accumulation the weight will be added to the memory when the balance becomes stable When the balance is s...

Страница 13: ...hts have been added To view the totals in memory press the Print key when the balance is at zero The display will show ACC xx where xx is the total number of readings and the total weight before retur...

Страница 14: ...ON F1 EL See section 6 2 Sets the backlight and audible alert beep SW ver 2 5 onwards F2 SEr See section 6 3 Sets the print parameters F3 oFF See section 6 4 Sets the auto power off parameter F4 SEt S...

Страница 15: ...andard weighing unit in UK USA 0 0022046 Lb Ounce Avoirdupois ounce 16 ounces make a pound 0 035274 oZ Drams An ancient unit of weight Equal to 1 16th of an ounce 0 564383 d Grains A basic weighing un...

Страница 16: ...e balance 2 After a few seconds the display will show the first function F1 UNT 3 Press the Mode key to select F2 EL 4 Press the 0 T key once to view the current settings for the backlight and twice t...

Страница 17: ...umulation when the Print key is pressed P2 Con Data is sent continuously Accumulation is disabled P3 AUT The weighing results will be sent to the communication port automatically whenever a stable rea...

Страница 18: ...There are 2 settings that the Highland can work with as follows FOr 1 Data format is with line headings and extra line feeds as shown in section 9 3 FOr 2 Data format is weight only Press the Mode ke...

Страница 19: ...LS You can select if the internal mass or an external mass is to be used to calibrate the balance 1 To set this parameter press the Mode key during self checking test when turning on the balance 2 Aft...

Страница 20: ...rrent value with the first digit flashing To change the value press to shift the position press Mode to increase the value and press Print to decrease the value The internal calibration weight should...

Страница 21: ...EO n STA Stability symbol range 0 to 5 0 is the smallest stability range and 5 is largest 2 STA n ZTR Weight Tracking Range 0 to 5 3 ZTR Press the 0 T key to view the current settings To change the se...

Страница 22: ...n as shown below To calibrate the handle is pushed to the side to lower the calibration mass INTERNAL CALIBRATION USING HANDICALTM 1 Press the on off key to turn the power on 2 Press the Smpl and Prin...

Страница 23: ...ollows Model HCB 123 HCB 153 HCB 302 HCB 602 HCB 602H Weight 1 60g 50g 100g 200g 200g Weight 2 120g 100g 200g 400g 400g Weight 3 150g 300g 600g 600g Model HCB 1002 HCB 1502 HCB 2202 HCB 3001 HCB 6001...

Страница 24: ...he scale on Load cell damaged Electronics damaged Remove any weight from the stainless steel pan and turn the balance off and back on again Try calibrating the balance Err 9 A D count is not stable wh...

Страница 25: ...6001 Maximum Capacity 1000 g 1500 g 2200 g 3000 g 6000g Readability 0 01 g 0 05 g 0 01 g 0 1 g 0 1 g Repeatability s d 0 02 g 0 1 g 0 02 g 0 2 g 0 2 g Linearity s d 0 03 g 0 15 g 0 03 g 0 3 g 0 3 g P...

Страница 26: ...ESE VALUES ARE FOR GUIDE PURPOSES ONLY 9 2 COMMON SPECIFICATIONS Interface USB and RS 232 bi directional Stabilization Time 3 Seconds typical Operating Environment M 15 C to 35 C 59 F to 95 F Power su...

Страница 27: ...ing operations parts counting or recalling of totals from memory will all be different All lines end with a carriage return and a line feed 0dH and 0aH in ASCII Format 1 Output The lines will include...

Страница 28: ...at The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t T cr lf Tares the scale to display the net weight This is the same as pressing 0...

Страница 29: ...y will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment Th...

Страница 30: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Страница 31: ...EN Adam Equipment Company 2018 31...

Страница 32: ...M EQUIPMENT is an ISO 9001 2008 certified global company with more than 40 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the...