© Adam Equipment Company 2006
10
6.5 PARTS
COUNTING
•
Before beginning, tare the weight of any container that will be
used, leaving the empty container on the scale.
•
For CBW- 6H, place the sample first and then press the
[Func] key.
For all other models first press the
[Func]
key to
begin. The scale will show "
P 10
" asking for a sample size of 10
parts. Change the sample size by pressing the
[Tare/
Ï
]
key.
The display will cycle through the options: 10, 20, 50, 100, 200
and back to 10.
•
Place the number of samples on the scale. The number should
match the options for parts counting, i.e., 10, 20, 50, 100 or 200
pieces.
•
Press the
[Zero/Enter]
key when the number matches the
number of parts used for the sample. As more weight is added,
the display will show the number of parts (pcs).
•
Press the
[%]
key to display unit weight (g/pcs or lb/pcs), Total
weight (kg or lb) or the count (pcs).
•
Press
[Func]
to return to normal weighing.
6.6 CHECK-WEIGHING
Check-weighing is a procedure to cause an alarm to sound when the
weight on the scale meets or exceeds the values stored in memory.
The memory holds values for a high limit and a low limit. Either or both
the limits can be used.
NOTE:
The alarm can be set to OFF (See the section 7.7 on
Parameter). In this case the display will indicate whenever the weight is
within or exceeds the limits by showing ‘OK’, ‘HI’ or ‘LO’.