The individual PLU values should be entered against specific items
before the weighing process starts so that the desired PLU’s can be
recalled during the weighing process.
The user can store and recall up to 103 PLU values as PLU1, PLU2, PLU3
and PLU00 to PLU99.
The keys labelled [PLU1] and [PLU2] are used to immediately recall the most
frequently used PLU values saved as PLU1 and PLU2. The [PLU+] key is
used to access the other values saved as PLU3 and PLU00 to PLU99.
To recall one of these PLU values the following procedure applies.
1.
To recall PLU1, simply press [PLU1].
2.
The same applies to PLU2, simply press [PLU2].
3.
To recall one of the other PLU values, press [PLU+]. The
display will show “
LOAd
” “
PoS 00
” ” ”. If a number (00 to
99) is entered immediately, then the value saved against the
entered PLU number will be recalled. If nothing is entered
within a few seconds of pressing the [PLU+] key, the value
saved for PLU3 will be recalled.
For example:
Press [PLU+].
Press [1] and then [4] immediately.
Display will show “
LOAd
” “
PoS 14
” ” ” and then the PLU
value for PLU 14 will be displayed.
OR
Press [PLU+].
Wait for few seconds.
Display will show “
LOAd
” “
PoS 00
” ” ” and then the PLU
value for PLU 3 will be displayed.
If the item is loaded on the pan, the Total Price window will show the total
cost. If nothing is loaded, only the PLU value saved for the location will be
displayed in the Unit Price window and the Total Price window will display
“