background image

 

4.0  KEY

 

DESCRIPTIONS 

 

 

 

 
[Tare/

]   

 

 

Sets the zero point for all subsequent weighing. The display shows zero. 
 
Tares the scale. Stores the weight currently on the scale as tare value, subtracts 
the tare value from the gross weight and shows the results. 
 
A secondary function,         is of “Enter” key used when setting up the value for the 
Parameters. 

[CHK/PRINT/

]

     CHK:  Selects  checkweighing.  Used  to  set  the  Low/High  weight  limits  while 

checkweighing. 
 
PRINT: Sends the results to a PC or a Printer using the RS-232 interface. It also 
adds  the  value  to  the  accumulation  memory  if  the  accumulation  function  is  not 
automatic.  
 

:  Up  directional  button  for  scrolling.  Also  used  for  incrementing  the  active  digit 

when setting a value for Parameters.

[Disp/Mode/

]

 

 

Selects  the  weighing  unit  to  be  displayed  from  those  which  are  enabled.  See 
parameter rS1 in section 7.2. 
 
A  secondary  function, 

  is  to  move  the  active/flashing  digit  to  the  right  when 

setting values for Parameters.

[Func/Set/

 

 

Selects  the  Functions  of  the  scale.  If  the  scale  is  weighing,  it  will  select  parts 
counting. If it is not in weighing mode, it will return the user to weighing.   
 
A  secondary  function  (SET)  will  bring  up  the  settings  menu.  Also  used  to  set 
values used for parameters

[

0

/Esc] 

 

 

Used to zero the scale. 
 
A secondary function (

ESC

) is to return to normal operation when the scale is in a 

Parameter setting mode.

/ ST/ CE]

  

 

To switch on and switch off the scale. 
 
ST: Secondary function allows the user to store/ recall checkweighing limits.

 
 

Содержание AGB 150aM

Страница 1: ...Adam Equipment AGB Bench Scale Software rev V 1 00 above...

Страница 2: ...Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Страница 3: ...d checkweighing 10 6 8 ACCUMULATED TOTAL 11 6 9 PERCENT WEIGHING 12 6 10 ANIMAL Dynamic WEIGHING 13 6 10 1 1 Animal weighing procedure 13 6 11 ANIMAL 2 DYNAMIC 2 WEIGHING 14 6 11 1 Animal 2 weighing p...

Страница 4: ...nt weighing The system includes automatic zero tracking audible alarm for check weighing semi automatic tare and an accumulation facility that allows individual weights or counts to be stored and the...

Страница 5: ...lb 30kg 175lb 80kg 260lb 120kg 0 0005lb 0 2g 0 001lb 0 5g 0 002lb 1g 0 005lb 2g 0 01lb 5g 0 0005lb 0 2g 0 001lb 0 5g 0 002lb 1g 0 005lb 2g 0 01lb 5g 0 001lb 0 5g 0 002lb 1g 0 004lb 2g 0 01lb 5g 0 02lb...

Страница 6: ...tery life 90 hours typical Battery Life is less when the backlight is used Interface RS 232 bi directional Interface Display 6 digits 40mm digit height LCD digital display with backlight Balance Housi...

Страница 7: ...s or surfaces Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid air movement such as from fa...

Страница 8: ...ng Also used for incrementing the active digit when setting a value for Parameters Disp Mode Selects the weighing unit to be displayed from those which are enabled See parameter rS1 in section 7 2 A s...

Страница 9: ...state of charge of the internal battery 6 0 OPERATION 6 1 ZEROING THE DISPLAY You can press the 0 Esc key at any time to set the zero point This will usually be necessary when the platform is empty Y...

Страница 10: ...ly the net weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will...

Страница 11: ...o the next digit Once you have set the desired sample size press the Tare key 6 6 PARTS COUNTING If parts counting is enabled it is possible to count parts using a sample of the parts to determine ave...

Страница 12: ...nabled When a weight is placed on the scale the LED s above the display will show if the weight is above or below the limits and the beeper will sound if the beeper is enabled Press the Func Set key t...

Страница 13: ...IMIT SET HIGH LIMIT is set to zero The display will be amber when the weight is less than the Low Limit Above the Low Limit the display backlight will be green CHK bP In The beeper will be off when th...

Страница 14: ...nit or parts counting that was active at the time the limits were set is reactivated 6 8 ACCUMULATED TOTAL The scale can be set to accumulate manually by pressing the CHK Print key or automatically wh...

Страница 15: ...of the original sample For example if 3500g is placed on the scale and percent weighing is selected the display will show 100 0 Remove the 3500g weight and place a 3000g weight The display will show 8...

Страница 16: ...ow Flt x where x is a value from 1 to 5 The higher the value the greater the amount of filter will be To increment the value shown press the key then press the Tare key to accept it 6 10 1 1 Animal we...

Страница 17: ...isplay will show LOAD and the Animal Dynamic weighing symbol The scale is now ready to weigh an unstable animal or sample on a weighing scale platform To use the Animal Weighing function it is necessa...

Страница 18: ...0 Esc key The scale will remain in the animal weighing mode until a new mode is selected using the Func Set key and Tare key to enter 6 12 HOLD PEAK FUNCTION Press Func Set and scroll through the list...

Страница 19: ...using the and directional keys Press Tare to enter a parameter Press 0 Esc to exit the scale parameter section and return to normal weighing This group of parameters is used to control the operation o...

Страница 20: ...AMETERS This group of parameters can be set by the user for setting the RS 232 active or not baud rate printing mode accumulation mode RS 232 language and user or scale ID numbers Pressing the Func Se...

Страница 21: ...sable the Accumulation on oFF off Printing mode Printing Mode Manual or Automatic mAn AUto P mAn Printer device Select the printer or device to print to ATP LP50 ATP Number of copies Select the number...

Страница 22: ...weight Print when Print M Esc key is pressed Do not accumulate 7 2 2 PC settings Parameter Description Options Default Values or setting baud rate Baud Rate 1200 2400 4800 9600 19200 38400 57600 1152...

Страница 23: ...oes not need to be turned on The battery should be charged for 12 hours for full capacity Near the display is an LED to indicate the status of battery charging When the scale is plugged into the mains...

Страница 24: ...Unit weight and number of parts are printed cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf If ID is zero it is left blank User ID 234567 cr lf cr lf Net Wt 1 234 Kg...

Страница 25: ...Animal Wt 1 500 Kg cr lf cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Peak Holt Wt 1 500 Kg cr lf cr lf cr lf c...

Страница 26: ...500 Kg cr lf cr lf Hold Wt 1000kg Peak holt wt 1000kg Animal wt 1000kg Ref wt 1000kg Percent 150 00 cr lf Unit wt 1 0234g Pieces 1000 PCS cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 5...

Страница 27: ...TE UNTER DER GRENZE DEBAJO DEL L MITE SOTTO IL LIMITE ABAIXO DO LIMITE Number of parts are above the limits ABOVE THE LIMIT SUP RIEUR LA LIMITE BER DER GRENZE ENCIMA DEL L MITE SOPRA IL LIMITE ACIMA D...

Страница 28: ...rm After pressing Tare Load will appear on the display Place the calibration test weight that matches the weight previously entered onto the scale weighing pan and press the Tare key to confirm Pressi...

Страница 29: ...ATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide furth...

Страница 30: ...ation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable battery that is des...

Страница 31: ...ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications...

Страница 32: ...4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974 9745 Fax 2...

Отзывы: