To  weigh  a  second  subject  press  the 

[

0

/Esc]

  key  and  the  display  will 

show 

“LOAD”

  and  the  function  will  be  ready  for  a  new  measurement,  if 

necessary  to  zero  the  display,  press  the 

[

0

/Esc]

  key  again,  and  then 

place the next animal on the scale

.

 The scale will detect the new weight and 

hold it as before. 

 

 

The  scale  will  remain  in  the  animal  weighing  mode  until  a

 

new  mode  is

 

selected using the

 [Func/ Set] 

key and 

[Tare/

]

 key to enter. 

 

6.11  ANIMAL

 

2

 

(D

YNAMIC 

2)

 

WEIGHING

 

 

The  scale  can  be  set  to  animal  2  (dynamic)  weighing  for  sequential  weighing  of  several 
items that are unstable. 
 
This  function  allows  the  user  to load  several  moving  items  into the  platform  at  once, the 
scale will take a measurement of all items included. The function will then ask the user to 
remove one of the items, and then it will automatically measure and printout the weight of 
the removed item. The function it will repeat this process until there are no items left, or the 
user stops the function.  
  

  Press

  [Func/Set]

  and  scroll  through  the  list  of  functions  using  the 

  and 

 

directional keys 
 

  Press

  [Tare/

to enter animal 2 weighing. The display will show 

“LOAD”

 and the 

Animal/Dynamic  weighing  symbol

.  The  scale  is  now  ready  to  weigh  an 

unstable animal or sample on a weighing scale platform.

 

 

 

  To  use  the  Animal  Weighing  function  it  is  necessary  to  set  the  amount  of  filtering 

required for the item to be weighed. More active animals will require a higher level 
of filtering to give a stable result. Press the 

[Disp/Mode]. 

The display will show “Flt 

x” where x is a value from 0 to 5.  The higher the value the greater the amount of 
filter  will  be.    To  increment  the  value  shown  press  the 

[

]  key  then  press  the

 

[Tare/

key to accept it. 

 

6.11.1 

 Animal 2 weighing procedure 

 

  With  the  weighing  scale  platform  empty  the  indicator  display  will  show 

“LOAD”

Place  containers  or  blankets  onto  the  platform  and  press  the

  [

0

/Esc] 

key  to 

remove the weight of the containers or blankets, alternatively, a long press on the 

[Tare/

]

 key, will retain the container or blanket value as “

NET

”.  

 

  Place the animals or sample to be weighed on the platform.    

 

  Press 

[Tare/

]

  key  to  start  to  the  measurement.  The  display  will  show  the  live 

measurements until a stable weight is determined. The time it takes for the stable 
value will depend upon the setting of the filter parameter in the first step.   

 

  When a stable reading is found, the display will show this value, and the display will 

Содержание AGB 150aM

Страница 1: ...Adam Equipment AGB Bench Scale Software rev V 1 00 above...

Страница 2: ...Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Страница 3: ...d checkweighing 10 6 8 ACCUMULATED TOTAL 11 6 9 PERCENT WEIGHING 12 6 10 ANIMAL Dynamic WEIGHING 13 6 10 1 1 Animal weighing procedure 13 6 11 ANIMAL 2 DYNAMIC 2 WEIGHING 14 6 11 1 Animal 2 weighing p...

Страница 4: ...nt weighing The system includes automatic zero tracking audible alarm for check weighing semi automatic tare and an accumulation facility that allows individual weights or counts to be stored and the...

Страница 5: ...lb 30kg 175lb 80kg 260lb 120kg 0 0005lb 0 2g 0 001lb 0 5g 0 002lb 1g 0 005lb 2g 0 01lb 5g 0 0005lb 0 2g 0 001lb 0 5g 0 002lb 1g 0 005lb 2g 0 01lb 5g 0 001lb 0 5g 0 002lb 1g 0 004lb 2g 0 01lb 5g 0 02lb...

Страница 6: ...tery life 90 hours typical Battery Life is less when the backlight is used Interface RS 232 bi directional Interface Display 6 digits 40mm digit height LCD digital display with backlight Balance Housi...

Страница 7: ...s or surfaces Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid air movement such as from fa...

Страница 8: ...ng Also used for incrementing the active digit when setting a value for Parameters Disp Mode Selects the weighing unit to be displayed from those which are enabled See parameter rS1 in section 7 2 A s...

Страница 9: ...state of charge of the internal battery 6 0 OPERATION 6 1 ZEROING THE DISPLAY You can press the 0 Esc key at any time to set the zero point This will usually be necessary when the platform is empty Y...

Страница 10: ...ly the net weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will...

Страница 11: ...o the next digit Once you have set the desired sample size press the Tare key 6 6 PARTS COUNTING If parts counting is enabled it is possible to count parts using a sample of the parts to determine ave...

Страница 12: ...nabled When a weight is placed on the scale the LED s above the display will show if the weight is above or below the limits and the beeper will sound if the beeper is enabled Press the Func Set key t...

Страница 13: ...IMIT SET HIGH LIMIT is set to zero The display will be amber when the weight is less than the Low Limit Above the Low Limit the display backlight will be green CHK bP In The beeper will be off when th...

Страница 14: ...nit or parts counting that was active at the time the limits were set is reactivated 6 8 ACCUMULATED TOTAL The scale can be set to accumulate manually by pressing the CHK Print key or automatically wh...

Страница 15: ...of the original sample For example if 3500g is placed on the scale and percent weighing is selected the display will show 100 0 Remove the 3500g weight and place a 3000g weight The display will show 8...

Страница 16: ...ow Flt x where x is a value from 1 to 5 The higher the value the greater the amount of filter will be To increment the value shown press the key then press the Tare key to accept it 6 10 1 1 Animal we...

Страница 17: ...isplay will show LOAD and the Animal Dynamic weighing symbol The scale is now ready to weigh an unstable animal or sample on a weighing scale platform To use the Animal Weighing function it is necessa...

Страница 18: ...0 Esc key The scale will remain in the animal weighing mode until a new mode is selected using the Func Set key and Tare key to enter 6 12 HOLD PEAK FUNCTION Press Func Set and scroll through the list...

Страница 19: ...using the and directional keys Press Tare to enter a parameter Press 0 Esc to exit the scale parameter section and return to normal weighing This group of parameters is used to control the operation o...

Страница 20: ...AMETERS This group of parameters can be set by the user for setting the RS 232 active or not baud rate printing mode accumulation mode RS 232 language and user or scale ID numbers Pressing the Func Se...

Страница 21: ...sable the Accumulation on oFF off Printing mode Printing Mode Manual or Automatic mAn AUto P mAn Printer device Select the printer or device to print to ATP LP50 ATP Number of copies Select the number...

Страница 22: ...weight Print when Print M Esc key is pressed Do not accumulate 7 2 2 PC settings Parameter Description Options Default Values or setting baud rate Baud Rate 1200 2400 4800 9600 19200 38400 57600 1152...

Страница 23: ...oes not need to be turned on The battery should be charged for 12 hours for full capacity Near the display is an LED to indicate the status of battery charging When the scale is plugged into the mains...

Страница 24: ...Unit weight and number of parts are printed cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf If ID is zero it is left blank User ID 234567 cr lf cr lf Net Wt 1 234 Kg...

Страница 25: ...Animal Wt 1 500 Kg cr lf cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Peak Holt Wt 1 500 Kg cr lf cr lf cr lf c...

Страница 26: ...500 Kg cr lf cr lf Hold Wt 1000kg Peak holt wt 1000kg Animal wt 1000kg Ref wt 1000kg Percent 150 00 cr lf Unit wt 1 0234g Pieces 1000 PCS cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 5...

Страница 27: ...TE UNTER DER GRENZE DEBAJO DEL L MITE SOTTO IL LIMITE ABAIXO DO LIMITE Number of parts are above the limits ABOVE THE LIMIT SUP RIEUR LA LIMITE BER DER GRENZE ENCIMA DEL L MITE SOPRA IL LIMITE ACIMA D...

Страница 28: ...rm After pressing Tare Load will appear on the display Place the calibration test weight that matches the weight previously entered onto the scale weighing pan and press the Tare key to confirm Pressi...

Страница 29: ...ATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide furth...

Страница 30: ...ation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable battery that is des...

Страница 31: ...ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications...

Страница 32: ...4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974 9745 Fax 2...

Отзывы: