ACV International
23
5.8.2
Horizontal wall and roof terminal with a combi duct
Appliance category: C13
CAUTION
Pipes for connecting the air supply and the combustion gas
flue between the appliance and the combi duct must have a
diameter of ø 80 mm.
•
ACV combi duct-horizontal.
For wall or roof terminal - horizontal.
•
ACV combi duct-horizontal.
For extension of a balcony/gallery discharge.
Permitted pipe lengths
Two-pipe
Air supply and combustion gas flue pipe (together ) excluding the length of the
combi duct.
Kompak HRE eco 12 and 18 Solo
100 meters
Kompak HRE eco 30 Solo
80 meters
Kompak HRE eco 40 Solo
60 meters
Concentric
Air supply and combustion gas flue pipe, excluding the length of the combi duct:
60/100
80/125
Kompak HRE eco 12 and 18 Solo
11 meters
29 meters
Kompak HRE eco 30 Solo
10 meters
29 meters
Kompak HRE eco 40 Solo
10 meters
29 meters
Combustion gas flue and air supply pipe
For assembly see section 5.8 Assembly general.
Assembly of combi duct horizontal wall terminal
1.
Fit the combi duct with a fall towards the appliance
2.
Make an opening of ø 130 mm in the wall at the position of the discharge.
3.
Cut the combi duct to the correct length according to the dimensions indicated.
4.
Fit the outlet grille and secure this to the inner pipe.
5.
Slide the combi duct into the opening and fit the rosettes to cover the opening.