ACV International
2
INDICE
1
SAFETY REGULATIONS
4
1.1
General ............................................................................................................................................................................................ 4
1.2
Central heating installation .............................................................................................................................................................. 4
1.3
Gas installation ................................................................................................................................................................................ 4
1.4
Electrical installation ........................................................................................................................................................................ 4
1.5
Drinking water installation (only in combination with external DHW tank) ....................................................................................... 4
1.6
Flue pipe and air supply................................................................................................................................................................... 4
2
Description of appliance
5
2.1
General ............................................................................................................................................................................................ 5
2.2
Operation ......................................................................................................................................................................................... 5
2.3
Operating modes ............................................................................................................................................................................. 5
2.4
PC Interface ..................................................................................................................................................................................... 7
2.5
Test program’s ................................................................................................................................................................................. 7
3
Principal components
8
4
Installation
9
4.1
Overall dimensions .......................................................................................................................................................................... 9
4.2
Installation location ........................................................................................................................................................................ 10
Installing the appliance ............................................................................................................................................................................... 11
5
Connection
12
5.1
Connecting CH installation ............................................................................................................................................................ 12
5.2
Connecting a DHW tank ................................................................................................................................................................ 13
5.3
Electrical connection ...................................................................................................................................................................... 14
5.4
Connect room thermostat .............................................................................................................................................................. 15
5.5
Gas connection .............................................................................................................................................................................. 16
5.6
Flue pipe and air supply................................................................................................................................................................. 17
5.7
Pipe lengths ................................................................................................................................................................................... 18
5.8
Balanced flue assemblies .............................................................................................................................................................. 20
5.9
Roof outlet Common Flue System ................................................................................................................................................. 30
6
COMMISIONING the appliance
32
6.1
Filling and venting the appliance and the installation .................................................................................................................... 32
6.2
Commissioning the appliance ........................................................................................................................................................ 33
6.3
Shutting down ................................................................................................................................................................................ 34
7
Setting and adjustment
35
7.1
Directly via the operating panel ..................................................................................................................................................... 35
7.2
Settting via the service code .......................................................................................................................................................... 36
7.3
Parameters .................................................................................................................................................................................... 36
7.4
Activating and de-activating DHW comfort .................................................................................................................................... 37
7.5
Setting maximum CH power .......................................................................................................................................................... 38
7.6
Setting pump setting ...................................................................................................................................................................... 38
7.7
Weather–dependent adjustment ................................................................................................................................................... 39
7.8
Conversion to different gas type .................................................................................................................................................... 40
7.9
Gas-Air ratio control. ...................................................................................................................................................................... 41
7.10
Checking the gas air ratio control .................................................................................................................................................. 42
8
FAults
46
8.1
Fault codes .................................................................................................................................................................................... 46
8.2
Other faults .................................................................................................................................................................................... 46
9
Maintenance
49
10
Technical specifications
51
10.1
NTC resistances ............................................................................................................................................................................ 51
10.2
Product Fiche according to CELEX-32013R0811, ANNEX iV ....................................................................................................... 52
10.3
Electrical diagram Kompakt HRE eco Solo ................................................................................................................................. 53
11
Warranty provisions
54
12
CE- Declaration
54