ACV 06627301 Скачать руководство пользователя страница 20

1 2 3 4

5

6 7

8

9

11

10

12

Horizontal installation

Vertical installation

Cold water

Hot water

CONNECTION

Essential instructions for the safety of persons and the environment
• 

Refer to the safety instructions for the installation. Failure to comply with these 

instructions can result in damages to the system, severe injuries or death.

• 

Hot water can burn! ACV recommends using a pre- set thermostatic mixing 

valve in order to provide hot water at a maximum of 60°C.

Essential instructions for the correct operation of the system
• 

The filling circuit of the DHW tank must be equipped with a safety group, 

comprised at least of a stop valve, a check valve, a safety valve set at 7 bar, and 

possibly, an expansion vessel of the appropriate size. Make sure that the circuit 

between the tank and the safety valve is always open.

• 

The third DHW tank connection, if any, can be used for the auxiliary DHW loop. 

If the connection is not used, replace the protective plug by a brass plug of the 

appropriate size. 

General remarks
• 

In certain countries the domestic kits must be approved.

• 

The circuit illustrations are basic principle diagrams only.

CONNECTION TO THE  DHW CIRCUIT (Typical wall installation)

Key

 1.  Filling valve
 2.  Pressure reducing valve (set at 4.5 bar)
 3.  Check valve
 4.  Stop valve

 5.  DHW expansion vessel
 6.  Pressure gauge
 7.  Safety valve (set at 7 bar)

 8.  Drain valve
 9.  Grounding
 10.  Stop  valve

11. Thermostatic mixing valve
12.  Hot water outlet

SLE - SLE Plus: A1007847 - 661Y2100 • D

Installation

•  To protect the primary circuit when the stop valves are closed, a safety 

valve and expansion vessel are imperative between the tank and the 

stop vales.

EN

20

Содержание 06627301

Страница 1: ...Smart E 130 160 210 240 300 Smart E Plus 210 240 300 Installation Operation Maintenance Instructions for the User and the Installer A1007847 661Y2100 D...

Страница 2: ...g connections 10 Domestic hot water connections 10 Main characteristics 11 Domestic hot water performances 11 Electrical characteristics 12 INSTALLATION 13 Package contents 13 Tools required for the i...

Страница 3: ...ING UP 25 Safety instructions to fill the tank 25 Filling 26 Checks before starting up 28 Starting up 28 MAINTENANCE 29 Periodic checks by the user 29 Annual maintenance 29 Draining 30 Bringing back i...

Страница 4: ...only be replaced by genuine parts Our water heaters are designed and manufactured for the exclusive purpose of heating and storing domestic hot water The domestic hot water heaters must only be heate...

Страница 5: ...SLE SLE Plus A1007847 661Y2100 D Product Information ENERGY LABELLING 5 EN...

Страница 6: ...SLE SLE Plus A1007847 661Y2100 D Product Information RATING PLATE EN 6...

Страница 7: ...ostat 60 80 C to set the domestic hot water DHW temperature 2 Manual reset high limit thermostat to restart the tank after overheating of the primary circuit 3 Connection plug to connect the electrica...

Страница 8: ...to heat by transfer fluid or independently with an optional electric resistance 1 Manual air bleed valve 2 Polypropylene shell 3 Dip tube 4 Electrical heating element optional 5 Outer steel tank prim...

Страница 9: ...20 1280 F mm 430 430 525 G mm 320 320 405 320 320 380 H mm 240 240 230 240 240 235 Smart E 130 Smart E 160 Smart E Smart E Plus 210 Smart E Smart E Plus 240 Smart E Smart E Plus 300 Max operating pres...

Страница 10: ...electrical heating element connection 6 Heating return connection heat pump 7 Flow heating circuit except Smart E 130 160 8 Return heating circuit except Smart E 130 160 1 Cold water inlet connection...

Страница 11: ...e temperature 10 C MAIN CHARACTERISTICS Main Characteristics Smart E 130 Smart E 160 Smart E Smart E Plus 210 Smart E Smart E Plus 240 Smart E Smart E Plus 300 Total capacity L 130 161 203 242 293 Pri...

Страница 12: ...thermostat of the tank cannot control the heating element To be mounted with an external box with a switch and a circuit breaker not included in the delivery Volt Amp Power Code 1 x 230 V 13 3 kW 1080...

Страница 13: ...fter removal of pack aging check the package contents and that the appliance is free of damages Contents packaging A domestic hot water tank A technical manual One energy label TOOLS REQUIRED FOR THE...

Страница 14: ...ion connect the stainless steel tank directly to the earth Use an adjustable earth clamp see example below on one of the DHW connections to connect to the earth Advised copper wire section 2 5mm Make...

Страница 15: ...eria exists including Legionella pneumophila if a minimum temperature of 60 C is not maintained in both the DHW tank and the hot water distribution network Essential instructions for the electrical sa...

Страница 16: ...used Discharge pipe D2 can now be plumbed into the soil stack but only soil stacks that can handle temperatures of 99 C or greater should be used Extract from The Building Regulation G3 Discharge pip...

Страница 17: ...e pipe size larger than the largest individual discharge pipe D2 to be connec ted 3 60 The discharge pipe should not be connected to a soil discharge stack unless it can be demonstrated that that the...

Страница 18: ...2 tundish with continuous fall See 3 56 Table G3 and worked example Tundish Discharge below fixed grating 3 61 gives alternative points of discharge Fixed grating Trapped gulley V a l v e o u t l e t...

Страница 19: ...t largest size Maximum resistance allowed for a straight length of 28mm pipe D2 from a G1 2 temperature relief valves equates to 18m Subtract the resistance of 4 No 28mm elbows at 1 0m each 4 0m There...

Страница 20: ...he appropriate size Make sure that the circuit between the tank and the safety valve is always open The third DHW tank connection if any can be used for the auxiliary DHW loop If the connection is not...

Страница 21: ...ixing valve 12 Air vent Cold water Hot water Domestic hot water kit option 1 Thermostatic mixing valve 2 Mixed water outlet 3 4 M 3 DHW expansion vessel connection 3 4 M 4 Safety unit 7 bar 5 Outlet h...

Страница 22: ...ON TO THE PRIMARY CIRCUIT 1 Primary circuit filling valve 2 Charging pump 3 Check valve 4 Primary circuit stop valve 5 Expansion vessel 6 Pressure gauge 7 Safety valve set at 3 bar 8 Drain valve 9 Sto...

Страница 23: ...0 D Installation EXAMPLES OF POSSIBLE COMBINATIONS OF THE SMART E AND SMART E PLUS Smart E Plus combined with a heat pump and floor heating system Smart E 210 240 300 combined with a boiler and floor...

Страница 24: ...bled 1 System filling valve 2 Safety valve set at 3 bar 3 Expansion vessel 4 Isolation valve heating system 5 Pressure gauge Essential instruction for the correct operation of the installation Connect...

Страница 25: ...to the ratio recommended in the local regulations Consult the manufacturer to determine the compatibility of the antifreeze with the tank s construction materials Essential instructions for the correc...

Страница 26: ...oiler 3 Open the air bleed valve 4 located on the top of the hot water tank 4 When the air is eliminated close the air bleed valve 4 Make sure the air bleed valve is tight FILLING Essential instructio...

Страница 27: ...SLE SLE Plus A1007847 661Y2100 D Starting Up 27 EN Cold water Hot water Figure 1 1 3 3 2 Figure 2 1 2 4 3 1 2...

Страница 28: ...orrectly connected and not leaking Check that the sensor of the thermostat is correctly positioned in the dry well see figures below STARTING UP If the tank is used as electric DHW tank only 1 Put the...

Страница 29: ...y unit drips periodically it may be due to an expansion problem or clogging of the valve For internal inspections the hand hole can be used If there is none use one of the water connections to insert...

Страница 30: ...ain the primary circuit of the hot water heater 1 Stop the charging pump 2 Isolate the primary circuit by closing the stop valves 1 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Ope...

Страница 31: ...op valve 4 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve 2 and the air vent 5 to drain the water from the DHW tank to the sewer 5 Close the drain valve 2 and th...

Страница 32: ...stat of the tank 3 Check if the charging pump works properly and replace if necessary 4 Check the safety thermostat on the tank and or the electric heating element and reset or replace if neces sary 5...

Страница 33: ...SLE SLE Plus A1007847 661Y2100 D 33 EN...

Страница 34: ...SLE SLE Plus A1007847 661Y2100 D EN 34...

Страница 35: ...SLE SLE Plus A1007847 661Y2100 D 35 EN...

Страница 36: ......

Отзывы: